GDYM-1A Hal Waji oo kali ah oo Tamarta Korontada ah Calibrator
GDYM-1A Hal waji oo koronto ah oo mitirka tamarta korantada ah waa qalab cabbiraadda cabbirro badan oo ka buuxa dhijitaal, hawl-badan iyo saxnaan sare.Ma aha oo kaliya in ay awood u si ay u calibrating qaladka, laakiin sidoo kale in la cabbiro danab, qiimaha hadda wax ku ool ah, awoodda firfircoon, awoodda falcelinta, awoodda muuqata, soo noqnoqda awoodda, factor awood, xidhiidhka wajiga, iwm Waxa ay si gaar ah ku haboon si loo saxo saxnaanta cabbirka Mitirka tamarta korantada ee wejiga kaliya ah ee qaybta korontada.
Hawlgal fudud oo degdeg ah, dhammaan hababka hawlgalka ayaa lagu soo bandhigay shaashadda.
●Si loo cabbiro mitirka tamarta korantada ee nidaamka cabbiraadda oo loo cabbiro saamiga korantada hooseeya.
●Isticmaalka tignoolajiyada xudunta u ah 32-bit ee 150MHz DPS, 16 xoogaa beddele sax ah oo sarreeya, khaladku aad ayuu u deggan yahay saxnaantuna waa sarraysaa (tani waxay leedahay farqi tayo leh oo leh calibrator-hal-waji leh chip mitir).
●Shaashadda LCD ee midabaysan ee weyn, waxay soo bandhigaysaa cabbirrada habaynta, iswaafajinta, cabbirrada korantada, khaladka iyo dhammaan xogta cabbiraysa si firfircoon.
●Isku-xidhka hadda jira waxa loo istcimaalaa in lagu matalo hadda uu keenay culays, kaas oo fududeeyay goobta shaqada oo wanaajisay hufnaanta shaqada.Waqtiga xaadirka ah ee terminalka iyo xajinta iyo sidoo kale awoodooda iyo wadarta awooda ayaa la soo bandhigi doonaa isku mar.
●Isticmaalka xajinta 500A iyo xajin yar oo hadda jirta si loo cabbiro saamiga CT danab hooseeya.
●Cabbir xogta iswaafajinta laga bilaabo 2-43 jeer, hadda iyo danabku waxay soo bandhigi doonaan wakhtiga dhabta ah qaab mowjad kasta, kaas oo ka caawiya in lagu xukumo gobolka goobta.
●Xisaabinta joogtada ah ee mitirka tamarta hal xilli garaaca tamarta korontada.
●Kaydi xogta 1000 mitir.
●Ku xidh kombuutarka RS232 isgaarsiin taxane ah.
●Iyada oo soo-saarka garaaca garaaca wadnaha oo hooseeya, ku habboon is-hubinta iyo kormeerka.
●Qalabeeyaha ayaa ku qeylin doona dhawaaq iyo iftiin marka uu siinayo 380V khadka tijaabada korantada.
●Marka xariiqda culeyska jilitaanka ee hadda uu khaldan yahay oo lagu xiray khadka dhexdhexaadka ah ee mitirka, ilaalinta tooska ah ee ugu horreysa kama soo baxayso hadda.Marka la samaynayo cilada mar labaad, fiyuuska difaaca labaad waa gubi doonaa, kaas oo khuseeya gebi ahaanba ilaalin.Qalabeeyaha ayaa soo kabsan doona ka dib marka uu beddelo fiyuuska.
●Fiyuusku wuu gubi doonaa markaXariiqda dardargelinta ayaa ku dhufatay 220V, kalibtarka ayaa soo kaban doona ka dib marka uu beddelo fiyuuska.
Qiyaasta Qiyaasta | Saxnaanta | ||
Voltage | 10-300V | ± 0.1% | |
Jilitaanka Hadda | 5A | ± 20% | |
Isku-qabsiga hadda | 100A, 500A | ±0.3%, ±0.5% | |
Terminalka hadda jira | 0.05-10 A | ± 0.1% | |
Awood | Isku-qabsiga hadda | 100A, 500A | ± 0.3%, ± 0.5% |
Terminalka | 10A | ± 0.1% | |
Xagasha wajiga | -180--+180° | ±0.1° | |
Soo noqnoqda | 45-55Hz | ±0.01Hz | |
Tamarta Korontada | 100A Clamp (yar) | 0.25A-110A | ±0.3%, ±0.5% |
500A isku dhejis | 25-1000A | ± 0.5% | |
Muujinta Range | 100A Xakamaynta Hadda: 0.01A-110A | ||
Gegida: 0.01A-10A | |||
Tamarta Korontada garaaca | FL=1000 imp/kW.h | ||
Voltage shaqeeya | AC 100 - 300 V | ||
Heerkulka shaqada | -25 ℃~45℃ | ||
Qoyaanka shaqaynaysa | <95% Ma jiro uumi | ||
Miisaanka | <1kg | ||
Mugga | 215*105*70mm |
GDYM-1A Calibrator | 1 set |
100A mitirka xajinta | 1 xabbo |
Software-ka Maamulka (CD-ROM) | 1 gabal |
Khadka garaaca mitirka elektiroonigga ah | 1 gabal |
Fiilada korantada | 1 gabal |
Xadhkaha korontada | 1 gabal |
232 khadka isgaarsiinta | 1 gabal |
Madaxa sawir-qaadista | 1 gabal |
0.5A Fiyuus | 1 gabal |
Kiiska qalabka | 1 gabal |
Buugga | 1 koobi |