GDPQ-300A Falanqeeyaha Tayada Awooda La Qaadan Karo
●Qalabku waa qalab tijaabo ah oo sax ah oo si gaar ah loo isticmaalo si loo ogaado dhibaatooyinka tayada korantada sida waveform qallooca, nuxurka iswaafajinta iyo dheelitir la'aanta saddexda weji ee shabagga korantada.Waxa kale oo ay leedahay hawlaha tijaabada cabbirka korantada iyo falanqaynta vector.
●Wuxuu si sax ah u cabbiri karaa danab, hadda, awoodda firfircoon, awoodda falcelinta, xagal wejiga, qodobka awoodda, soo noqnoqda iyo xuduudaha kale ee korantada.
●Waxay muujin kartaa jaantuska vector ee tamarta la qiyaasay iyo hadda.Isticmaaluhu wuxuu baari karaa jaantuska vector si uu u helo saxnaanta fiilooyinka qalabka cabbiraadda.
●Hadda waxa lagu cabbiraa is beddelka nooca xajin.Hawlwadeenku uma baahna inuu ka gooyo wareegga hadda jira marka uu ku cabbirayo beddelka nooca xajin ee hadda jira, cabbirka ayaa loo samayn karaa si ku habboon oo ammaan ah.Noocyada kala duwan ee xirmooyinka ayaa lagu dooran karaa iyadoo loo eegayo cabbirka cabbirka isticmaalaha.
●Waxay cabbiri kartaa oo ay falanqeyn kartaa tayada korantada AC ee ay bixiso shabagga tamarta ee macaamiisha.Waxay cabbiri kartaa oo ay falanqayn kartaa: leexashada soo noqnoqda, leexashada danab, korantada saddex-waji ah oo la oggol yahay dheelitir la'aanta iyo is-waafajinta xadhkaha.
●Waxay soo bandhigi kartaa danab hal-waji ah iyo mowjadaha hadda jira waxayna isku mar soo bandhigi kartaa danab saddex-waji ah iyo mowjadaha hadda jira.
●Dhammaan goobaha imtixaanku waxay leeyihiin shaqo quful shaashadda si ay u fududayso akhriska iyo falanqaynta xogta isticmaalaha.
●Korjoogteynta isbedbedelka culeyska: Cabbirka iyo falanqaynta isbedbeddelka qalabka korantada ee kala duwan ee ay sababto tayada korantada ee shabakadda tamarta ee xaaladaha kala duwan ee hawlgalka.Diiwaanada wakhtiga iyo kaydinta isbeddelada tamarta, hadda, awoodda firfircoon, awoodda falcelinta, awoodda muuqata, soo noqnoqoshada, marxaladda, iyo xuduudaha kale ee awoodda.
●Kormeerka firfircoon ee hagaajinta qalabka korantada iyo habka hawlgalka si loo caawiyo isticmaalayaasha xalinta dhibaatooyinka habka hagaajinta qalabka korontada iyo hawlgelinta.
●Awoodda lagu tijaabiyo oo lagu falanqeeyo cabbirrada firfircoon ee magdhowga tamarta falcelinta iyo shaandhaynta aaladaha nidaamyada tamarta iyo tiro ahaan qiimeeyaan shaqadooda iyo tilmaamayaasha farsamada.
●Dejin kara wakhtiga kaydinta ee kala duwan, si joogto ah u kaydin kara xogta iyadoo loo eegayo wakhtiga la qorsheeyay;
●Ku-dhisan kaydinta xogta awoodda-weyn, waxa loo kaydin karaa si joogto ah in ka badan 18 bilood oo u dhexeeya 1 daqiiqo, taas oo buuxin karta baahida dhibcaha baaritaanka muddada-dheer.
●Qalabku waxa uu leeyahay interface USB ah, kaas oo si fudud xogta si toos ah ugu koobi kara kombayutarka maamulka asalka.
●Iyada oo la socota software-ka maaraynta xogta xoogga leh, xogta wakhtiga-dhabta ah ee la muunadeeyay ayaa si toos ah loogu dhejin karaa kombuyuutarka maaraynta asalka si aad u dhammaystiran oo degdeg ah uga baaraandegto gadaasha.
●Iyada oo leh kalandarka joogtada ah, shaqada saacada, taariikhda dhabta ah ee bandhigga iyo wakhtiga.Xogta tijaabada iyo natiijooyinka waa la keydin karaa isku mar, waxaana lagu dhejin karaa kombuyuutarka iyada oo loo sii marayo dekedda taxanaha ah, iyada oo loo marayo software-ka maaraynta asalka (ikhtiyaarka) si loo gaaro maareynta kombuyuutarka yar-yar ee xogta, oo leh awoodo warbixineed oo xooggan.
●Waxay qaadataa shaashad weyn oo LCD ah sida bandhigga, interface-ka hawlgalka Ingiriisiga iyo interface interface LCD oo leh macluumaad degdeg ah dabeecad Ingiriisi iyo bandhig cabbirro badan.Interface wada hadalka mashiinka-mashiinku waa saaxiibtinimo.
●3 daqiiqo ma jiro wax hawlgal ah Bandhig LCD wuxuu si toos ah u galayaa habka badbaadinta tamarta, si loo kordhiyo nolosha batteriga.
●Badhanka silikoonka wax qabad leh, dareemo wanaag, cimri dheer, naqshad macquul ah, fududahay in la shaqeeyo.
●Ku-dhisnaanta awoodda sare, waxqabadka sare ee lithium-ion baytari dib loo dallaci karo, wuxuu shaqayn karaa 10 saacadood ka dib markii si buuxda loo dallaco.
●Cabbir yar, miisaan fudud, fudud in la qaado, waxaa loo isticmaali karaa cabbiraadda goobta, sidoo kale waxaa loo isticmaali karaa sida qalabka cabbirka heerka shaybaarka.
Gelida | |
Qiyaasta korantada | 0-200V-800V, baabuur ssixir |
Qiyaasta hadda jirta | CT: 5A/25A (standard) 100A/500A (ikhtiyaar) 400A/2000A (ikhtiyaar) |
Qiyaasta xagal wejiga | 0 ~ 359.99° |
Qiyaasta soo noqnoqda | 45~65Hz |
Kanaalka Voltage | 3 kanaal (UA, UB, UC) |
Kanaalka hadda jira | 3 kanaalka (IA, IB, IC) |
Waqtiyada falanqaynta iswaafajinta ee ugu badan | 63 jeer |
Muddada kaydinta joogtada ah ee ugu badan ee 1 daqiiqo u dhexaysa | 18 bilood |
Saxnaanta | |
Qaybta cabbiraadda korantada | |
Voltage | ±02% |
Soo noqnoqda | ±0.01Hz |
Hadda, awood | ± 0.5% |
Marxaladda | ±0.2° |
Qaybta tayada awoodda | |
Khaladka dulqaadka tamarta aasaasiga ah | ≤0.5% FS. |
Cilada dulqaadka ee aasaasiga ah | ≤1% FS |
Khaladka cabbiraadda farqiga u dhexeeya tamarta aasaasiga ah iyo hadda: | ≤0.2° |
Khaladka cabbiraadda nuxurka danab Harmonic | ≤0.1% |
Khaladka cabbiraadda nuxurka hadda taagan ee harmonic | ≤0.2% |
Khaladka isku-dheellitir la'aanta korantada ee saddexda weji: | ≤0.2% |
Cilad ka leexinta korantada | ≤0.2% |
Cilad kala duwanaansho koronto | ≤0.2% |
Heerkulka shaqada | -10 ℃ ~ +40 ℃ |
Awood ku dallacaadda | AC 220V, 45Hz-55Hz |
isticmaalka tamarta martida loo yahay | ≤3VA |
wakhtiga ugu badan ee shaqada batteriga | ≤10 saacadood |
Dahaarka | (1) Iska caabbinta dahaarka ee korantada iyo terminaalka gelinta hadda ee daaska waa ≤100MΩ. (2) Dhammaadka gelinta korantada shaqadu waxay ku socotaa inta jeer ee awoodda 1.5KV (qiimaha wax ku ool ah) inta u dhaxaysa daasadaha dibadda, waxayna qaadataa 1 daqiiqo in la tijaabiyo. |
Cabirka | 320mm *240mm *130mm |
Miisaanka | 2.0kg |