GDPQ-5000 Falanqeeyaha Tayada Korontada
GDPQ-5000 Falanqeeyaha Tayada Korontadu waa qalab tijaabo ah oo dhamaystiran oo ay si taxadar leh u soo saartay shirkadeena oo si gaar ah loogu talagalay tijaabada goobta ee seddex waji, hawlo badan iyo caqli-gal ah, hawlgalka mashiinka-mashiinka.Way fududahay in la isticmaalo, soo bandhigida shaashadda LCD ee weyn, xallinta sare, interface ee Shiinaha iyo Ingiriisiga labadaba, qaab-dhismeedka qolofka aan shoogga lahayn iyo wixii la mid ah.Isla mar ahaantaana cabbiri kara 4-kanaalka hadda (ABC saddex weji iyo silig dhexdhexaad ah), 4-channel danab (ABC saddex-waji oo danab ah iyo danab dhexdhexaad ah oo dhulka ah), qiimaha ugu sarreeya ee danab hadda, ugu badnaan / ugu yar qiimaha muddo , Qodobka saddex-waji ee dheelitir la'aanta, flicker danab waqti-gaaban, transformer K factor, awoodda firfircoon, awoodda fal-celinta, awoodda muuqata, awoodda awoodda iyo barokaca, awoodda firfircoon, awoodda falcelinta, awoodda muuqata, wadarta guud ee qallooca iyo iswaafajinta, iwm;Muuji qaab-waveform-waqtiga-dhabta ah, jaantusyada saamiga saamiga iswaafajinta ee danabka hadda jira;Si firfircoon u qabso isbeddelka degdega ah ee danabka hadda socda, la socodka bilawga hadda, la socodka xuduudaha awoodda oo soo saar liiska alaarmiga, soo saar jaantuska isbeddelka xogta tijaabada wakhtiga dheer.
GDPQ-5000 Falanqeeyaha tayada korantada wuxuu qaataa DSP + ARM naqshadaynta labajibbaaran ee processor-ka, DSP waxaa loo isticmaalaa ururinta xogta iyo habaynta algorithm, ARM waxaa loo isticmaalaa nidaamka isgaarsiinta iyo farsamaynta mashiinka-mashiinka;Helitaanka calaamadaha Analog waa 2 qaybood AD7655 ee shirkadda ADI.Qaraarka AD7655 waa 16 bit waana 4 kanaal muunad isku mid ah.Qiyaasta muunada ugu sareysa waxay gaari kartaa 1 MSPS, si loo hubiyo saxnaanta kanaalka iyo hufnaanta macluumaadka, oo aan la waayi doonin isbeddellada ku-meel-gaarka ah ee shabakadda, waxay si sax ah u ogaan kartaa mowjadaha ku-meel-gaarka ah ee kor u kacaya iyo hoos u dhacaya si xooggan, oo waxay sameeyaan mawjada hakad degdeg ah ;Inta jeer ee shaqada DSP waa in ka badan 200 MHZ, si ay u awoodaan in ay la socdaan waqtiga ku korontadu oo si firfircoon u hagaajiyo soo noqnoqda muunad si loo xaqiijiyo wada-shaqeynta soo noqnoqda awoodda iyo soo noqnoqda muunad;Isticmaalka muraayadda midabka 5.6-inch LCD, xallinta 640 dhibcood x 480 dhibcood, oo leh kala duwanaansho midab kala duwan oo u dhexeeya xuduudaha wajiga, waveform, jaantuska vector, saamiga iswaafajinta, adeegsaduhu wuxuu noqon karaa mid hufan oo caqli badan oo faham gobolka. ee cabbiraadaha korantada.Xusuusta fiishka ee ku dhex jirta waxay kaydin kartaa 60 kooxood oo shaashado ah isku mar, 150 kooxood oo qabasho danab ku meel gaadh ah/qaabka mowjadda hadda jira, iyo 12800 kooxood oo liiska digniinaha ah.Bilaabida qaabka ogaanshaha hadda waxa uu si joogto ah u qabsan karaa qaab-dhismeedka mowjadda hadda socda ilaa 100 s.Ku dhex-dhismay kaadhka xusuusta 2G si loo kaydiyo rikoorka qalooca isbedbeddelka, duubista isku mar ah ee 20 (waxay dooran kartaa iyadoo loo eegayo baahida) ururin xogta hal mar shantii ilbiriqsiba.
Waxa kale oo loo yaqaan Falanqeeyaha Tayada Awoodda ee Saddexda Waji, Falanqeeyaha Tayada Awooda Kala Duwan, kaas oo isku mar la socda hawlaha falanqeeyaha harmonic, mitirka volt-ampere,tijaabiyaha cabbirka korontada.Waxay khusaysaa warshadaha korontada, petrochemical, metallurgy, tareenka, shirkadaha macdanta, hay'ad cilmi sayniska, waaxda metrological.Gaar ahaan ku habboon falanqaynta iyo ogaanshaha dhammaystiran ee dhammaan tamarta, hadda, awoodda, awoodda, harmonic, xuduudaha korantada wajiga.
2.1.Shaqada cabbirka
●Waveform-muujinta-waqtiga-dhabta ah (4 kanaal danab / 4 kanaal hadda ah).
●Qiimaha dhabta ah ee RMS ee danabyada iyo hadda.
●Qaybaha DC ee danabyada.
●Qiimaha ugu sarreeya ee hadda iyo korantada.
●Ugu yaraan iyo ugu badnaan wareegga nus-wareegga RMS hadda iyo qiimaha danab.
●Muujinta jaantuska Phassor.
●Cabbirka harmonic kasta ilaa 50.
●Jaantusyada barku waxay muujinayaan saamiga iswaafajinta ee hadda iyo tamarta weji kasta.
●Wadarta qallooca iswaafajinta (THD).
●Firfircoon, falcelin, awood muuqata, weji iyo isugeyn.
●Firfircoon, falcelin, tamar muuqata, weji iyo wadar ahaanba.
●Transformer K factor.
●Qodobbada awoodda (PF) iyo arrimaha barokaca (DPF ama COSΦ).
●Flycker-ka muddada-gaaban (PST).
●Saddex weji oo aan dheellitirnayn (hadda iyo danab).
2.2.Shaqada qabsashada ku meel gaadhka ah
La socoshada isbeddelka degdegga ah ee cabbiraadaha korantada ee hadda jira, oo ay ku jiraan isbeddellada korantada ee hadda jira, kor u kaca hadda jira, sag-goynta iyo kala goynta sahayda gaaban, kororka ku-meel-gaadhka ah, saamaynta hadda iyo danab hadda socda dhalanrog degdeg ah.Qalabku waxa ay kaydin karaan 150 nooc oo mawjado ku meel gaar ah isku mar.
2.3.Bilaabida la socodka hadda
La socoshada xadhkaha xadhkaha iyo xawliga bilawga ah marka qalabka korantadu bilaabmayo, waxay caawisaa in si sax ah loo naqshadeeyo awooda.Waxa lagu soo bandhigi karaa qalooca kor u kacaya/dhicista ee RMS ee geedi socodka bilowga, qalooca baqshadda ee bilowga hadda, qaab waveform oo ah 4 kanaal hadda iyo 4 kanaal oo danab ah.Duubista qiyaastii 100s ka dib kicinta, kaydi hadda/voltage degdega ah iyo qalooca waveform ee wareeg kasta 100s.
2.4.Diiwaangelinta shaxda isbeddelka iyo kaydinta shaqada
Ku kaydi dhammaan cabbirrada tijaabada ee hawlaha tijaabada aasaasiga ah (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms, Athd, Acf, Aunb, KF, W, VAR, VA, PF, COSφ, TANφ), 50 harmonics danab, 50 harmonics hadda.Oo abuur qalooca isbeddelka.Diiwaangeli xogta wakhti dheer iyadoo loo eegayo baahida (doorashada isku dhafka ah ee 20 si aad u duubto xogta hal mar shantii ilbiriqsiba, waxaad duubi kartaa ilaa 300 maalmood.).
2.5.Shaqada alaarmiga
U deji qiyamka xaddidan ee hadba baahida loo qabo, la socodka qiyamka haddii la badiyo, haddii la dhaafo waxay dhalin doontaa diiwaanka digniinta, sida: danab, hadda, dheellitir la'aan, saamiga iswaafajinta, soo noqnoqoshada, awoodda firfircoon, wadarta qallooca iswaafajinta.Waxaad u habayn kartaa 40 alaarmiga kala duwan, koox kastaa waxay dejin kartaa cabbiraadyo kormeer oo kala duwan (oo ay ku jiraan 50 harmonics, wadarta 123 cabbir oo kala duwan) iyo xaddidaadaha qiyamka, sidoo kale waxay dejin karaan waqtiga ugu gaaban ee xad-dhaafka ah.Logu wuxuu ka koobnaan karaa ilaa 12,800 alaarmiga.
2.6.Shaqada sawir-qaadista
Shaashad kasta waa la keydin karaa (sawir-qaadasho shaashad ah), isla markaana waxay si toos ah u diiwaangelisaa waqtiga iyo qaabka tijaabada.Sida badbaadin kara danab iyo qaab mawjadaha hadda jira, jaantuska bar harmonic, jaantuska phasorkaiwm. Waxa ay kaydin kartaa ugu badnaan 60 sawir oo shaashad ah.
2.7.Shaqada isgaarsiinta
Kumbiyuutarka kula xidhiidh USB, Software-ka la socodka waxa uu soo bandhigi karaa qaab mawjadaha falanqaynta tayada awoodda, akhrinta mowjadda ku meel gaadhka ah, duubista jaantuska isbeddelka, diiwaanka digniinta, sawir-qaadista, iyo soo bandhigida kombiyuutarka.
2.8.Dejinta shaqada
Isticmaaluhu wuxuu habayn karaa wakhtiga iyo taariikhda, qaabaynta isbarbardhigga shaashadda iyo dhalaalka, qeexida weji kasta midabada qalooca.
Doorashada nooca isku xirka shabakada
Habaynta nooca dareemayaasha hadda iyo saamiga danab.
2.9.Liiska caawimada
Marxalad kasta oo hawlgal ah waxay riixi kartaa furaha "caawinta" si aad u hesho macluumaadka khuseeya.
3.1.Xaaladda aasaasiga ah iyo xaaladda shaqada
cCunsurka saamaynta | Shayga tijaabi | Xaaladda saldhiga | Xaaladda shaqada |
heerkulka deegaanka | Dhammaan xuduudaha | (23±2)°C | -10°C ~ 40°C |
Qoyaanka qaraabada | Dhammaan xuduudaha | 40% ~ 60% | <80% |
Waji-ilaa-dhexdhexaad danab | Dhammaan xuduudaha | (100± 1%) V | 1.0V~ 1000V |
Waji-ilaa-weji danab | Runta RMS weji-ilaa-weji danab | (200± 1%) V | 1.0V~ 2000V |
Hadda | Run RMS hadda | (5±1%) A | 10mA~ 10A |
Inta jeer ee shabakada | Dhammaan xuduudaha | 50Hz 0.1Hz | 40Hz ~ 70Hz |
Isbedelka wajiga | Awood firfircoon iyo tamar firfircoon | Cosφ=1 | Cosφ: 0.2 ~ 1.0 |
Awood falcelineed iyo tamar falcelineed | Sinφ=1 | Sinφ: 0.2 ~ 1.0 | |
Harmonic | Dhammaan xuduudaha | <0.1% | 0.0% ~ 100% |
Isku dheelitir la'aanta korantada | Dhammaan xuduudaha | <10% | 0.0% ~ 100% |
Danab shaqaynaya ee qalabka | Dhammaan xuduudaha | DC9.8V±0.1V | DC9.5V~ 10.5V |
Beer koronto oo dibadda ah, goob birlab ah | Dhammaan xuduudaha | Waa in laga fogaado | |
booska tijaabada | Cabbiraadaha la xidhiidha hadda | Silig la tijaabiyay oo ku yaala bartamaha xajinta. |
3.2.Tilmaamaha guud
Korontada | Baakadaha lithium-ion ee dib loo dallaci karo 9.6V, dabaysha kaydinta. |
Tilmaamaha baytari | Astaanta baytarigu waxay tusinaysaa tamar daadsan.Marka danabku aad u hooseeyo, si toos ah u xidhid 1 daqiiqo ka dib. |
Isticmaalka tamarta | Isticmaalka hadda ee tijaabada caadiga ah 490mA, si joogto ah u shaqeynaya 8 saacadood. |
Qaabka muuqaalka | Shaashadda midabka LCD, 640dhibcood × 480dhibcood, 5.6 inji, muuqaalka muuqaalka: 116mm × 88mm. |
Cabbirka xajin | 008B xajin yar oo fiiqan: 7.5mm × 13mm; |
Cabbirrada qalabka | L×W×H: 240mm×170mm×68mm. |
Tirada kanaalada | 4U/4I. |
Waji ilaa waji danab | 1.0V ~ 2000V. |
Waji-ilaa-dhexdhexaad danab | 1.0V ~ 1000V. |
Hadda | 008B xajinta hadda: 10mA ~ 10.0A; |
Soo noqnoqda | 40Hz ~ 70Hz |
Halbeegyada korontada | W, VA, Var, PF, DPF, cosφ, tanφ. |
Xuduudaha tamarta | Waa, waa, waa. |
Harmonic | Dalabka 0~50. |
Wadarta qallooca harmonic | Dalbo 0 ~ 50, weji kasta. |
Habka khabiirka | Haa |
Tirada Diiwaanada Ku Meel Gaarka ah | 150 qaybood. |
Voltage flicker | Haa |
Bilaabida qaabka hadda | Haa, 100 ilbiriqsi |
3 weji oo aan dheeli tirnayn | Haa |
Diiwaangeli | 300 maalmood (diwaangelin isku mar ah 20 cabbir, qor hal dhibic 5tii sekan kasta). |
Ugu yaraan/Max qiimaha la duubay | Cabbiraadda qiimaha ugu badan iyo kan ugu yar ee muddo ah. |
Digniin | 40 nooc oo kala duwan oo xul ah, 12,800 waxay dejiyaan diiwaannada digniinta. |
Meesha ugu sarreysa | Haa |
Muujinta jaantuska Phassor | Si toos ah |
Awoodda sawir-qaadista | 60. |
Luuqadda liiska | Ingiriis |
Isgaarsiinta | USB |
Si toos ah u dami | Marka ololaha qaylo-dhaanta la bilaabo ama la raadinayo ku-meel-gaar, qabsasho degdeg ah, ama duubista isbeddelku waa la sugayaa ama socdaa, qalabku si toos ah uma damiyo. |
Qaab kale oo tijaabo ah, 15 daqiiqo bilaa furayaal, xidhid toos ah kadib 1 daqiiqo. | |
Shaqada dhabarka | Haa, ku habboon isticmaalka habeenkii iyo meel mugdi ah. |
Miisaanka | Hawl wadeen: 1.6kg (oo leh baytari). |
008B xajin yar oo fiiqan: 170g × 4; | |
Dhererka fiilada tijaabada danab | 3m |
Dhererka siliga dareemayaasha hadda | 2m |
Heerkulka shaqadaiyo huurka | -10 ° C ~ 40 ° C;ka hooseeya 80% Rh. |
Heerkulka iyo qoyaanka kaydinta | -10 ° C ~ 60 ° C;ka hooseeya 70% Rh. |
Cidhiidhiga galitaanka | Cidhiidhiga galitaanka tamarta tijaabada: 1MΩ. |
U adkeyso danab | U adkeyso 3700V/50Hz sinusoidal AC danab 1 daqiiqo inta u dhaxaysa fiilooyinka qalabka iyo qolofka. |
Dahaarka | Inta u dhaxaysa fiilooyinka qalabka iyo qolofka ≥10MΩ. |
Qaab dhismeedka | Dahaar laba jibaaran, oo leh dahaarka gadhka-ilaalinta gariirka. |
Si badbaado leh u xukuma | IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, heerka wasakhowga: 2. |
3.3.Saxnaanta qalabka (marka laga reebo dareenka hadda jira)
Sida ay u kala horreeyaan u soo bandhig xogtan soo socota (oo ku saabsan aasaaska xaaladaha aasaasiga ah iyo dareemayaasha hadda ku habboon, toosan oo qumman, ma jiro isbeddel weji).
Cabbirka | Range | xallinta bandhig | Cilada ugu badan ee xadka tixraaca |
Soo noqnoqda | 40Hz ~ 70Hz | 0.01Hz | ± (0.03) Hz |
Run RMS weji-ilaa-dhexdhexaad danab | 1.0V~ 1000V | Xalka ugu yar 0.1V | ± (0.5%+5dgt) |
Runta RMS wejiga-ilaa heerka danab | 1.0V~ 2000V | Xalka ugu yar 0.1V | ± (0.5%+5dgt) |
danabka DC | 1.0V~ 1000V | Xalka ugu yar 0.1V | ± (1.0%+5dgt) |
Run RMS hadda | 10mA~ 10A | Xallinta ugu yar 1mA | ± (0.5%+5dgt) |
Ugu sarreeya ee danab-ilaa-dhexdhexaad ah | 1.0V~ 1414V | Xalka ugu yar 0.1V | ± (1.0%+5dgt) |
Korantada weji-ilaa-wejiga ugu sarreysa | 1.0V~ 2828V | Xalka ugu yar 0.1V | ± (1.0%+5dgt) |
Halka ugu sarreysa ee hadda | 10mA~ 10A | Xallinta ugu yar 1mA | ± (1.0%+5dgt) |
Qodobka ugu sarreeya | 1.00 ~ 3.99 | 0.01 | ± (1%+2dgt) |
4.00 ~ 9.99 | 0.01 | ± (5%+2dgt) | |
Awood firfircoon | 0.000W~ 9.999kW | Xallinta ugu yar 0.001W | ± (1%+3dgt) Cosφ≥0.8 |
± (1.5%+10dgt) 0.2≤Cosφ<0.8 | |||
Awood falcelineed, firfircooni ama karti leh | 0.000VAR~ 9.999kVAR | Xallinta ugu yar 0.001VAR | ± (1%+3dgt) Sinφ≥0.5 |
± (1.5%+10dgt) 0.2≤Sinφ<0.5 | |||
Awood muuqata | 0.000VA~ 9.999kVA | Xallinta ugu yar 0.001VA | ± (1%+3dgt) |
Qodobka awoodda | -1.000~ 1,000 | 0.001 | ± (1.5%+3dgt) Cosφ≥0.5 |
± (1.5%+10dgt) 0.2≤Cosφ<0.5 | |||
Tamar firfircoon | 0.000Wh~ 9999.9MWh | Xallinta ugu yar 0.001Wh | ± (1%+3dgt) Cosφ≥0.8 |
± (1.5%+10dgt) 0.2≤Cosφ<0.8 | |||
Tamar falcelineed, firfircooni ama karti leh | 0.000VARh ~ 9999kii.9MVARh | Xallinta ugu yar 0.001VARh | ± (1%+3dgt) Sinφ≥0.5 |
± (1.5%+10dgt) 0.2≤Sinφ<0.5 | |||
Tamar cad | 0.000Vah ~ 9999.9MVAH | Xallinta ugu yar 0.001Vah | ± (1%+3dgt) |
xagal wejiga | -179°~ 180° | 1° | ± (2°) |
Tanφ (VA≥50VA) | -32.76~ 32.76 | Xalka ugu yar 0.001 | φ: ± (1°) |
Isbedelka wajiga ee qodobka awoodda (DPF) | -1.000~ 1,000 | 0.001 | φ: ± (1°) |
Saamiga Harmonic (dalabka 1 ilaa 50)(Vrms>50V) | 0.0% ~ 99.9% | 0.1% | ± (1%+5dgt) |
xagal harmonic (Vrms>50V) | -179°~ 180° | 1° | ± (3°) waafaqsan nidaamka 1 ilaa 25 |
± (10°) waafaqsan nidaamka 26 ilaa 50 | |||
Wadarta harmonic saamiga (THD ama THD-F)≤50 | 0.0% ~ 99.9% | 0.1% | ± (1%+5dgt) |
Qodobka qallooca (DF ama THD-R)≤50 | 0.0% ~ 99.9% | 0.1% | ± (1%+10dgt) |
Transformer K factor | 1.00 ~ 99.99 | 0.01 | ± (5%) |
3 weji oo aan dheeli tirnayn | 0.0% ~ 100% | 0.1% | ± (1%) |
3.4.Dareenka hadda jira
Nooca dareemayaasha hadda | Run RMS hadda | Khaladka ugu badan ee dhabta ah ee RMS hadda | Khaladka ugu badan ee xagasha wajiga φ |
008B xajinta hadda | 10mA ~ 99mA | ± (1%+3dgt) | ± (1.5°), Gacmaha≥20mA |
100mA ~ 10.0A | ± (1%+3dgt) | ± (1°) | |
040Xajinta B hadda | 0.10A~ 0.99A | ± (1%+3dgt) | ± (1.5°) |
1.00A ~ 100A | ± (1%+3dgt) | ± (1°) | |
068Xajinta B hadda | 1.0A ~9.9A | ± (2%+3dgt) | ± (3°) |
10.0A ~ 1000A | ± (2%+3dgt) | ± (2°) | |
300Fxajin hadda | 10A ~ 99A | ± (1%+3dgt) | ± (3°) |
100A ~ 3000A | ± (1%+3dgt) | ± (2°) |
Fiiro gaar ah: xajinta hadda iyo qalabka waa in lagu xidhaa kuwa u dhigma, lamana gelin karo si ka soo horjeeda.
4.1.Qaabeynta caadiga ah
Maya | Magacaabidda | Tirada |
1 | Qalabka martida loo yahay. | 1 |
2 | Bacda qalabka. | 1 |
3 | Dareemayaasha hadda jira. | 12 (3 nooc) |
4 | Tijaabada fiilooyinka | 5 (jaalle, cagaar, casaan, buluug, madow) |
5 | clips Yaxaaska. | 5 |
6 | Baaritaanka tijaabada | 5 |
7 | adabtarada tamarta heeganka ah. | 1 |
8 | Xadhkaha taariikhda USB. | 1 |
9 | Software CD. | 1 |
10 | Xidhmada baytariyada lithium | 1 (qalabka lagu dhex dhisay) |
11 | 2GB xusuusta. | 1 (Ku xidh qalabka) |
12 | Buugga, kaarka dammaanadda, caddaynta. | 1 |
4.2.Miisaanka
Maya | Magacaabidda | Miisaanka |
1 | Qalabka martida loo yahay. | 1.6kg (oo leh baytari). |
2 | 008B xajin yar oo hadda af leh. | 170g*4. |
3 | 040B wareegxajin hadda. | 185g*4 |
4 | 068B wareegxajin hadda. | 530g*4 |
5 | 300FGariiradda hadda jirta ee dabacsanxajin(oo leh integrator). | 330g*4 |
6 | Tijaabi fiilooyinka iyo adabtarada korontada. | 900g. |