Qalabka Tijaabada Korantada Sare

Qalabka Tijaabada Korantada Sare

HV HIPOT waxay soo saartaa noocyada kala duwan ee qalabka tijaabada tamarta sare.

Waxaan nahay alaab-qeybiye hal-joojin ah oo loogu talagalay dhammaan alaabada u adkeysiga korantada sare ee ku saleysan baahidaada.

Qalabka Tijaabada Korantada Sare (1)
Qalabka Tijaabada Korantada Sare (2)

1. GDYD Taxanaha AC/DC Hipot Test Set

Tijaabada u adkeysiga inta jeer ee korontadu waa habka tooska ah ee waxtarka leh ee lagu tijaabiyo xoogga dahaarka ee qalabka korantada, qalabka, ama mishiinnada.Waxay hubisaa cilladaha khatarta ah taasoo hubisa in qalabka korantada uu si joogto ah u shaqeeyo.

Qalabka Tijaabada Hipot AC/DC, oo sidoo kale loo yaqaan AC/DC qalabka tijaabada dielectric, waxay tijaabin kartaa noocyo badan oo shaybaar ah, oo ay ku jiraan:

• Wareegtada
• Qalabka beddelka
Dib u xirid
• Xargaha
• Capacitors
• CT/PT
• Matoorada hawada sare
• Lebenka baaldiga usha kulul
• Dhalooyinka vacuum
• galoofyada caagga ah iyo kabaha
• Bustayaal dahaaran, xadhko
• Culaysyo kale oo badan oo MV iyo HV ah

Moodooyinka caadiga ah waxaa laga heli karaa 10kV-300kV AC.

Unugga kantaroolku waxa uu leeyahay saddex nooc oo xulashada,

• GDYD-M taxane ah oo muujinaya tilmaame

• GDYD-D taxanaha kontoroolka bandhiga dhijitaalka ah

• GDYD-A taxane ah oo otomaatig ah PLC kantaroole

Qalabka Tijaabada Korantada Sare (3)
Qalabka Tijaabada Korantada Sare (4)

2. AHabka Imtixaanka Resonant C

Tijaabada resonant AC waxay isticmaashaa habka dhawaaqa si ay ugu adkaysato tijaabinta korantada.Waxaa si gaar ah loogu talagalay awoodda waaweyn iyo walxaha tamarta sare leh, oo ay ku jiraan:

• Xadhkaha korantada
• Transformers koronto
• Dab-dhaliye iyo koronto-dhaliye
• GIS
• Baar baska
• CVT

Walxaha tijaabada awooda leh sida fiilada korontada, GIS, transformers iwm, waxaan badiyaa isticmaalnaa habka tijaabada soo noqnoqda ee doorsooma, taxanaha GDTF ee Nidaamka Imtixaanka Resonant AC.

Walxaha tijaabada inductive-ka ah sida matoorada, koronto-dhaliyeyaasha, CVT iwm., waxaan badiyaa isticmaalnaa habka tijaabada hagaajinta inductance, taxanaha GDTL ee Nidaamka Imtixaanka Resonant AC.

Qalabka Tijaabada Korantada Sare (5)
Qalabka Tijaabada Korantada Sare (6)

3. GTaxanaha DYT Nidaamka Imtixaanka Bixinta Qaybeed

Qaar ka mid ah moodooyinka ayaa ah koronto bilaash ah, oo loogu talagalay inay u adeegaan ilaha AC ee sii daynta qayb ahaan iyo tijaabinta factor factor/tan delta.Nidaamka waxaa loo qaabayn karaa iyadoo lagu saleynayo shay tijaabo oo kala duwan, iyadoo la adeegsanayo habka soo noqnoqda awoodda ama habka tijaabada dhawaaqa.

Qalabka Tijaabada Korantada Sare (7)
Qalabka Tijaabada Korantada Sare (8)

4. Taxanaha GIT SF6 Gaaska Dahaarka Mobil High Voltage Nidaamka Tijaabada Qaybka

Waxaa si gaar ah loogu talagalay GIS danab sare, transformers GIS.

Waxay samayn kartaa tijaabada hoose:

Inta jeer ee awoodda ama inta jeer ee doorsoomaha u adkaysta tijaabada danabka
• Tijaabada dheecaanka qaybeed
• Tijaabada saxnaanta beddelka GIS

Faa'iidooyinka

• Korontada sare ee la helay ayaa si fiican loo xiray oo lagu ilaaliyay weelasha, ilaalinta amniga qofka, ma jirto faragelin dibadda ah.
• Cabbiraad sax ah.
• Nooca ugu nabdoon ee tijaabada tamarta sare.
• Haddii la sameeyo nooca buushka ee HV, aaladda hydraulic ayaa la keenay si fudud loo qaado.
Nidaamka xorta ah ee corona ee dhabta ah.

Qalabka Tijaabada Korantada Sare (9)
Qalabka Tijaabada Korantada Sare (10)

5. VLF AC Hipot Tijaabada

Qalabka Tijaabada ee VLF AC Hipot waxaa si fiican loogu isticmaalaa fiilooyinka u adkeysanaya tijaabada korantada.

 

6. GDiyaarinta Tijaabada Hipot Taxanaha DZG

Taxanaha GDZG ee Qalabka Tijaabada Hipot ee DC waxaa loo isticmaalaa in lagu tijaabiyo danab sare oo DC ah oo loogu talagalay xirayaasha zinc oxide, xirayaasha magnetic magnetic, fiilooyinka korantada, koronto-dhaliyeyaasha, furayaasha wareegga iyo qalabka kale.Danab lagu qiimeeyay waa 30-500kV.

Qalabka Tijaabada Korantada Sare (11)
Qalabka Tijaabada Korantada Sare (12)

7. GDFR taxane High Voltage Qaybiye

HV HIPOT waxay keeni kartaa qaybiye danab sare oo sax ah.Dhammaan moodooyinka waxaa shahaado ka helay shaybaadhka HV ee qaranka.

GDFR-C1 AC/DC qaybiyaha danab sare

GDFR-C2 AC qaybiyaha danab sare

GDFR-C3 DC qaybiyaha danab sare

GDFR-C4 VLF qaybiyaha tamarta sare

GDFR-C5 Qaybiyaha korantada Impulse


Fariintaada noo soo dir:

Halkan ku qor fariintaada oo noo soo dir