GDPQ-300E Falanqeeyaha Tayada Korontada
GDPQ-300E Falanqeeyaha Tayada Korontadu waa aalad la qaadi karo oo lagu tijaabinayo laguna falanqeynayo tayada hawlgalka nidaamka tamarta.Waxay la socotaa oo ururisaa xogta wakhtiga dheer ee socda, waxay sidoo kale bixisaa falanqaynta iswaafajinta iyo falanqaynta tayada awooda.Dhanka kale, waxay ku qalabaynaysaa software falanqaynta xogta, kaas oo xogta cabbirka lagu dhejin karo PC.
●ARM iyo DSP, 16M byte xusuusta.
●Shaashada taabashada, aad u fudud oo ku habboon.
●Cabbirka xogta iyo kaydinta, waxaa lagu dhejin karaa PC.
●Qaab dhismeedka moduleka, naqshad macquul ah iyo hawlgal la isku halayn karo.
●cusboonaysiinta software fudud oo ku haboon.
●Falanqaynta faahfaahsan ee xogta cabbirka software-ka falanqaynta xogta tayada awoodda ee PC.
Hawlaha ogaanshaha mitirka
No | Walxaha | Sharaxaada |
1 | Voltage/Hadda/Soo noqnoqodka | Waxay cabbiri kartaa saddex-danab wajiga, koronto line eber, hadda saddex waji, eber line hadda, inta jeer. Waxa uu soo bandhigi karaa RMS, qiimaha ugu sarreeya, saamiga mowjadda/mawjada ugu sarreysa, qaabka hirarka, jaantusyada isbeddelka iwm. |
2 | Hcabbirka mawjada hubkament | Waxay cabbiri kartaa hirarka aasaasiga ah ee danab iyo hadda iyo2-50 jeer harmonicsmawjad.Natiijooyinka cabbiraadda waxaa ka mid ah hufnaanta is-waafajinta, nuxurka is-waafajinta, nuxurka is-waafajinta, iyo wadarta is-waafajinta (THD).Histograms iyo isbeddellada jaantusyoiwm. |
3 | Cabirka interharmonic | Waxay cabbiri kartaa 0.1 ~ 19.9 waqtiyo interharmonics ee danab iyo hadda.Natiijooyinka cabbiraadda waxaa ka mid ah qaybaha interharmonic iyo qiyamka wax ku oolka ah ee qaybta hoose, heerka nuxurka interharmonic iwm. waxay soo bandhigi kartaa histogaraamyada, jaantusyada isbeddelka, iwm. |
4 | Cabbirka awoodda | Waxay cabbiri kartaa saddex-waji afar-silig/saddex-waji saddex-silig ah awood muuqata (tamar koronto), awood firfircoon (tamar koronto), Awood falcelineed (tamar koronto), factor power iwm., waxay soo bandhigi kartaajaantusyada isbeddelka; qiyaasi kartaa dalbashada of 1, 5, 10, 15, 30 60 daqiiqo. |
5 | Qiyaasta dheelitir la'aanta saddex waji | Waa awoodcabbir saddex-waji afar-silig / saddex-waji saddex-waji koronto nidaamka korontada iyo qaybta isku xigxiga togan ee hadda, qaybta isku xigxiga taban, qayb isku xigxiga eber, heerka isku xigxiga taban, darajada isku xigta ee eber;xagal wejiga oo ah saddex waji oo danab ah iyo hadda,vector, isbeddel jaantusyo. |
6 | Flicker | 1 daqiiqo flicker, 10 daqiiqo flicker gaaban, 2 saac oo cabbir flicker dheer |
7 | Korontadu Bararka / Qulqulka / Joojinta | Soo ogow iyoqoryo koronto barara, sags iyo hakad dhacdooyinka. |
8 | Srabitaanka hadda | Baadhista oo qor kor u kac dhacdooyinka hadda jira |
9 | Awood harmonic | Waxaa lagu ogaan karaa 2 ~ 30 waqtiyo awoodda is-waafajinta, waxay muujin kartaa histogram, isbeddeljaantusyoiwm. |
10 | Mowjadda xoogga | Ccabbir isbeddelka degdegga ah ee awoodda (firfircoon, falcelin, awood muuqata) iyadoo loo eegayo wakhtiga loo dejiyay (1 ~ 5 daqiiqo) |
11 | Ku-meel-gaadhka | Cogaanshaha danab ku meel gaadh ah oo ka dheer 20 microse seconds |
8 | Diiwaanka la socodka | Waxay diiwaangelin kartaa cabbirrada tayada awoodda joogtada ah ee gobolka muddo dheer, oo ay ku jiraan danab / hadda / soo noqnoqoshada, is-waafajinta, awoodda, isku-dheellitir la'aanta saddex-waji, isbeddelka / flicker, iyo muddada duubista waxaa lagu hagaajin karaa 3 ilbiriqsi ilaa 30 daqiiqo. |
9 | oscilloscope Digital ah | Daawo foomamka mawjada danab/guud ee hadda jira |
Tilmaame kasta oo sax ah oo loogu talagalay hawlaha ogaanshaha
Shayga | Cabbirka kala duwan | Cabbir saxnaanta | Odhaah |
Voltage/ hadda / inta jeer | THree Voltage: 1000V (qiimaha waxtarka leh) ZKorontada khadka ero: 70V (qiimaha waxtarka leh) Three heerka hadda: 6000A (qiimaha wax ku ool ah, 1000A dareeraha hadda ee ikhtiyaari ah) Zero line hadda: 25A (qiimaha wax ku ool ah) FBaahida: 40-70Hz | Voltage:0.1%rdg±0.05%fs Hadda: 0.2%rdg±0.05%fs Fbaahida: akhriska±0.01Hz | HHadda, waxaan u isticmaalnaa inta jeer ee danab wajiga A sida inta jeer ee cabbirka |
Cabbirka hirka harmonic | Voltage harmonic: THD+Hirarka aasaasiga ah+ 2-50 jeer mawjada harmonic Charmonic degdeg ah: THD+Hirarka aasaasiga ah+ 2-50 jeer mawjada harmonic | Hirarka korantada ee harmonic: Uh≥1% UN, ±5% Uh; Uh<1% UN, ±0.05% UN Hirarka harmonic hadda: Ih≥3% IN, ±5% Ih; Ih<3% IN, ±0.15% IN | |
Inter harmonicmawjadcabbir | Vharmonic oltage: 0.1 ~ 19.9 jeerInter harmonicmawjad . Charmonic degdeg ah: 0.1 ~ 19.9 jeerInter harmonicmawjad | VoltageInter harmonicmawjad: Uih≥1% UN,5% Uih; Uih<1% UN,0.05% UN; HaddaInter harmonicmawjad: Iih≥3% IN,5%Ih; Iih<3% IN,0.15% IN | |
Pdeyn / Tamar koronto | Aawoodda firfircoon: 700kVA Rawoodda firfircoon: 700kVAR Qodobka awoodda: 0.00 ~ 1.00 Atamarta firfircoon: 10000kWh Atamarta cad: 10000kVAh Rtamarta firfircoon: 10000kVARh Acelceliska awoodda: 0.00-1.00 | Afirfircoon: akhris±0.5% Acad: akhris±0.5% Falcelin: akhris±0.5% Power factor: reading±0.005 | |
Twejiga hree dheelitir la'aanta | Fdanab aan cago lahayn: 1000V (qiimaha waxtarka leh) Fhadda: 6000A (qiimaha waxtarka leh) Finta jeer ee aan joogsiga lahayn: 40-70Hz Plaakiin xagal: 0-360degree Udheelitirnaan: 0.0% -100% | Vheerka sare: 0.1% rdg±0.05%fs Csocodka: 0.2%rdg±0.05%fs Fbaahida: akhriska±0.01Hz Phas angle: reading±0.3 darajo Vdheelitir la'aanta oltage: akhriska±0.2% Cdheelitir la'aanta degdega ah: akhriska±0.2% | Halkan, waxaan u isticmaalnaa inta jeer ee korantada wejiga sida wadarta inta jeer ee cabbirka |
Voltage Flicker | 1 daqiqo ayaa si fudud, waqti gaaban flicker, waqti dheer flicker | 1 daqiiqo oo liidata:±5.5% 10 daqiiqo oo gaaban:±5% 2 saacadood oo wakhti dheer ah ayaa soo jiidanaya:≤±5% | |
Korontadu barar, quusto oo joojiso | La soco oo diwaangeli bararka hal-waji/waji badan oo danab ah, hoos u dhaca danab iyo damin ku meel gaar ah | Mawjadda nuska ah ee RMS, wakhtiga bilawga, muddada, wakhtiga dhamaadka qaladka ± 10ms | Ilaa 40 diiwaan gelinta dhacdooyinka |
Kor u kaca Hadda | La soco oo diiwaan geli qulqulka qulqulka hal-waji/waji badan | Qiimaha rms-mawjadda nuska ah, wakhtiga bilawga, muddada, wakhtiga dhamaadka khaladka ± 10ms | Jooji cabbiraadda markaad qabanayso dhacdo |
Awoodda hirarka harmonic | Wadarta wakhtiyada awooda iswaafajinta: 1 ~ 30th Wadarta awoodda firfircoon ee harmonic:∑P Wadarta guud ee awoodda falcelinta ee harmonic:∑Q Wadarta guud ee awoodda firfircoon ee harmonic togan: +∑P Wadarta guud ee awoodda firfircoon ee harmonic taban: -∑P Wadarta guud ee awooda falcelis ee harmonic togan: +∑Q Wadarta guud ee awooda falcelis ee harmonic taban: -∑Q | Akhriska awoodda iswaafajinta: ± 0.5% | |
Mowjadda xoogga | Waxay ogaan kartaa dhererka 1, 3, 5 daqiiqo ee firfircoon, falcelinta, muuqata qiimaha korantada mawjada badhkeed, duubista isbeddelka awoodda | Akhriska awoodda nuska ah: ± 0.5% | |
Ku meel gaadh | Ku-meel-gaadhka korantada ee ku salaysan qiime magac ahaan ka badan 120% | 1.twakhtiga ugu yar ee dhacdooyinka la qiyaasi karo waa in ka badan 20 microsecond 2.suurtogalnimada qabashada dhacdada 98.7% | 20 dhacdo ayaa lagu kaydin karaa hal cabbir |
Mdiiwaanka ontoring | RHalbeegyada ecord waxaa ka mid ah danab, hadda, soo noqnoqoshada, korantada/mawjada harmonic hadda (wadarta harmonic+1-25 jeer harmonic), tdheelitir la'aanta wejiga hore;Firfircoon/firfircooni/awood muuqata, qodobka awoodda;isbedbeddelka/lixinta | Inta u dhaxaysa kaydinta xogta: 3s ~ 30min Muddadu waa 3s, wadarta wakhtiga kormeerkuna waa 16h; Muddadu waa 30min, wadarta wakhtiga la socodkana waa 960h. | |
Doscilloscope ee indhaha | Three Voltage wajiga, saddex weji hadda, eber line danab iyo eber line hadda hir mowjad degdeg ah | Max.inta jeer ee muunad: 200kHz Min.inta jeer ee muunad: 100Hz |
●Wareegga gelinta signalka korantada:
Gelitaanka tooska ah, cilad-gelinta gelinta: 1MΩ, 20pF
Cabbirka cabbirka: danab wax ku ool ah 1000V
Isticmaalka tamarta: in ka yar 0.5VA/waji
●Wareegga gelinta hadda:
Helitaanka dadban
Cabbirka cabbirka: Qiimaha hadda wax ku oolka ah 1A, 5A, 10A, 100A, 500A, 1000A, 3000A (dooro dareemaha hadda u dhigma)
Isticmaalka tamarta: In ka yar 0.5VA/waji
●Cabbir inta jeer ee calaamadaha: 40Hz-70Hz
●Shaashadda muuqaalka: 5.7 inch 640 * 480 LCD midab leh oo leh shaashad taabasho ah
●Kaydinta xusuusta: 128M byte FLASH
●Dekadda kaydinta dibadda: USB (ku xidh USB disk)
●Korontada shaqaynaysa: Li-bateriga dib loo dallaci karo, 5-6 saacadood oo wakhti shaqo ah oo si buuxda loo dallaco
●Korontada: AC100-240V/DC 16.8V-1A adabtarada korontada
Tijaabiye | 1 set |
5A xajinta hadda | 3 xabbo |
Siliga tijaabada korantada | 1 gabal |
Adabtarka tamarta | 1 gabal |
Beddel siliga | 1 gabal |
Gudub QC | 1 koobi |
Buugga Isticmaalaha | 1 koobi |
Warbixinta tijaabada warshadda | 1 koobi |
Liiska baakad | 1 koobi |