GDDO-20C AC/DC Qalabka Cabbirka Mitirka Korontada
GDDO-20C AC/DC Electric Meter Calibration Aaladda waxaa loo isticmaalaa in lagu ogaado qaladka aasaasiga ah ee qalabka korontada ee kala duwan ee nidaamka korontada, oo ay ku jiraan voltmeter, ammeter, wattmeter, ohmmeter, hal weji & saddex weji AC mitir tamarta (ikhtiyaarka) iyo qaladka aasaasiga ah ee mitirka volt-ka DC iyo ammeter.
Qaybta mitirka, waxay u qaadanaysaa soo noqnoqoshada awoodda saxda ah ee AC sida tignoolajiyada xudunta u ah, kaas oo ka kooban processor-ka signalka dhijitaalka ah (DSP) iyo 16-god oo xawaare sare leh oo analoog-digital ah beddele;Isha ishaarada, waxa ay isticmaashaa DSP iyo 16-digit xawaaraha sare ee analoog-digital beddele si ay u samaysato isha ishaarada ee soo saarta signalka hirka seeraha iyo calaamada hirarka qallooca.
●Heerka saxda ah ee 0.05.Marka la cabbiro korantada AC, AC hadda iyo awoodda firfircoon, qalabku wuxuu ku qalabaysan yahay beddelaha dhijitaalka ah / soo noqnoqda (DFC) oo leh soo noqnoqoshada shaqada oo ka sarreysa 60kHz iyo kala duwanaansho hadda jira oo badan, markaa saxnaanta sare ayaa la dammaanad qaaday.
●Mowjadda qallooca ee 2 ~ 31 jeer, tirada, waqtiyada iyo baaxadda harmonics, iyo wejiga iswaafajinta ee hirka aasaasiga ah dhamaantood waa la qorsheyn karaa.
●6.5-inji midab TFT LCD, muuqaal cad oo dhalaalaya.
●Iyada oo leh dekedda isgaarsiinta RS232.
●Iyada oo leh awood weyn oo xusuusta aan kacsanayn, waxay kaydin kartaa natiijooyinka imtixaanka 300 mitir ee tijaabada, aragtida xogta iyo shaqada gelinta xogta.
●Iyada oo la isku halleyn karo, fududahay in la shaqeeyo.
Wax soo saarka inta jeer ee awoodda AC | |
Baaxadda korantada (V) | 50, 100, 200, 400, 600 (800V waa ikhtiyaari), Max.awoodda wax soo saarka 20VA |
Kala duwanaanshaha hadda (A) | 0.5, 1, 2.5, 5, 10, 20, Max.awoodda wax soo saarka 20VA |
Kala duwanaanshaha hagaajinta korantada | 0 ~ 130%, hagaajinta ganaaxa 5*10 |
Kala duwanaanshaha hagaajinta hadda | 0 ~ 130%, hagaajinta ganaaxa 5*10 |
Saxnaanta tamarta, hadda, tamarta firfircoon iyo tamarta | 0.05% |
Xaqiijinta awoodda falcelinta iyo tamarta | 0.1% |
Saxnaanta wajiga hadda ilaa heerka danab | 0.05° |
Soo noqnoqda | Qiyaasta hagaajinta: 45 ~ 65Hz, Hagaajinta hagaajinta: 0.001Hz Dejinta saxnaanta qiimaha: 0.01Hz |
Marxaladda | Kala duwanaanshaha hagaajinta: 0 ~ 359.99° Hagaajinta hagaajinta: 0.01° Dejinta saxnaanta qiimaha: 0.05° |
Darajada qallooca ee danab iyo qaabka wax soo saarka hadda | ≤0.3% |
Xasiloonida danab, hadda iyo wax soo saarka tamarta | ≤0.01%/60s (qiimaha ugu sarreeya-ilaa-ugu sarreeya) |
Harmonics | 2-31 jeer Balaadhan: 0 ~ 20% Wajiga ganaaxa: 0.01°*N ("N" waxa loola jeedaa nidaamka waafaqsan) |
Wax soo saarka DC | |
Baaxadda korantada (V) | 0.075, 75, 150, 300, 500, 1000, Max.awoodda wax soo saarka 20W |
Kala duwanaanshaha hadda (A) | 0.5, 1, 2.5, 5, 10, 20, Max.awoodda wax soo saarka 20W |
Kala duwanaanshaha hagaajinta tamarta iyo hadda | 0 ~ 120% (kuma jiraan 1000V), hagaajinta ganaaxa 5*10 |
Xasilloonida danab iyo wax soo saarka hadda | ≤0.01%/60s (qiimaha ugu sarreeya-ilaa-ugu sarreeya) |
Saxnaanta qiimaha dejinta danab | 0.05% |
Saxnaanta qiimaha dejinta hadda | 0.1% |
Saxnaanta soosaarka 75mV (Load ≥5Ω) | 0.1% |
Halbeegyada guud | |
Korontada | Hal waji 220V± 10%, 50Hz±5% |
Isticmaal shuruudaha | 20℃±10℃, ≤85%RH |
Cabirka | 460*460*175mm |
Miisaanka | Qiyaastii 20kg |
Munug | 1 set |
Aluminiumalloy box | 1 set |
Xadhiga korantada | 1 pc |
Test line oo leh xiriiriye | 1 pc |
Khadka tijaabada (DC 75mV) | 1 pc |
Tijaabi khadka tamarta korantada garaaca wadnaha | 1 pc |
Xadhiga isgaadhsiinta | 1 pc |
Psawir-qaade | 1 pc |
Isticmaale'hagaha | 1 koobi |
Warbixinta tijaabada warshadda | 1 koobi |