GDCR1000C Tijaabada Isku Xirka Wajiga Aan La Xiriirin
GDCR1000C, GDCR1000D tijaabiyaha wejiga ee aan xidhiidhka ahayn waa horumar wayn oo laga gaaray habka ogaanshaha isku xigxiga wajiga dhaqameed.Ogaanshaha isku xigxiga wejiga dhaqameedku waa in laga xayuubiyo tiirka isku xirka fiilooyinka saddexda weji leh, lagu xidho saddex xajin oo qaawan ama tijaabin cirbadaha mitirka taxanaha wejiga ilaa saddex xariiqo dab qaawan, halka GDCR1000C iyo GDCR1000D ay qaadanayaan pincers cabbirka induction aan xidhiidh la lahayn.Isku xigxiga wejiga waxaa lagu ogaan karaa iyada oo aan loo baahnayn in laga siibo siliga oo aan la taaban siliga dabka-sare ee qaawan, kaliya iyada oo si toos ah loogu xajinayo saddex xabbo oo heer sare ah oo dahaarka ah maqaarka dahaarka ee siliga dabka saddexda weji siday u kala horreeyaan.Isla mar ahaantaana, tilmaanta acousto-optic ee heerka togan ama dib u noqoshada marxaladda isku xigxiga ee saadka korantada ee saddexda weji ayaa la heli karaa.Waxaa jira afar magnet oo xooggan oo ku yaal dhabarka qalabka, kuwaas oo lagu dhejin karo sanduuqa qaybinta si loo isticmaalo.
GDCR1000C, GDCR1000D tijaabiyaha wejiga aan la xidhiidhin ayaa leh hawlaha kormeerka wareegga, kormeerka awoodda fudud, raadinta wareegga wareegga, goobta jabinta, dayactirka khadka iyo wixii la mid ah.
GDCR1000C, GDCR1000D ogaanshaha wejiga aan xidhiidhka ahayn waa mid degdeg ah, ku habboon oo sahlan in lagu soo bandhigo jaleeco, si weyn u wanaajinaya badbaadada tijaabada goobta, si wax ku ool ah u ilaalinaysa badbaadada shakhsi ahaaneed ee hawlwadeenada, iyo kordhinta wax soo saarka!Waa qalab badbaado oo loogu talagalay isku xigxiga wejiga korontada ee saddexda weji, ogaanshaha mootada iyo dayactirka khadka.
GDCR1000C & GDCR1000D:
Qaabka | Tijaabi siligdibaddadhexroorka |
GDCR1000C | ø1.6mm~ø16mm |
GDCR1000D | ø10mm~ø40mm |
Shaqada | PHase check(wejiga togan, wejiga dambe, wejiga maqan), hubinta khadka tooska ah, goobta jabinta, dayactirka khadka |
Korontada | DC 3V 2 unugga qallalan ee alkaline (LR6),joogto ahisticmaalka waqti ku saabsan 70 saacadood |
Kala duwanaanshaha tooska ah | AC 70 ~ 1000V, 45 ~ 65Hz |
Tijaabi cabbirka siliga | Dibaddadhexroor ø1.6mm~ø16mm or ø10mm~ø40mm(ikhtiyaar) |
Muujinta LED | [Toganwaji] 4 nalalka ogaanshaha wejiga waxay shidmaan saacada dhan; [rewejiga aayadda]4ogaanshaha wajiganalalkaSi isdaba joog ah u shid saacada dhinaceeda. [khadka tooska ah] L1, L2 iyo L3nalalka shidinta u dhaxaysa dejinta danab; [wejiga maqan] L1 ama L2 ama L3 ma shidan. [furanwareegga] Nalalka L1 ama L2 ama L3 ma shidan. |
Gariir | [Wejiga togan] Qalabku wuxuu sii daayaa qaylo-dhaan gaaban oo kala go'a; [rewejiga aayadda] Qalabku waxa uu sii daayaa dhawaaqyo dhaadheer oo joogto ah. |
Tilmaanta baytariga | Tilmaamaha AWOODDA ayaa iftiimaya ka dib marka la shido;BATTERIGA HOOSEEYA wuu shidaa marka korontadu ku filnaato |
Magnetism | Waxaa jira afar magnets oo ku xiran dhabarka qalabka, kuwaas oo ku xiran sanduuqa qaybinta waxayna u adkeysan karaan tayada 800g. |
Xir | Qiyaastii 5 daqiiqo ka dib, qalabku si toos ah ayuu u dami doonaa. |
Cabirka | L 70mm* H 75mm* W30mm |
Cdhererka siliga laambad | 0.6m |
Wsideed | Qiyaastii 200g (oo ay ku jirto baytari) |
Wxaalad orking | -10℃~55℃;<80%rh |
Sxaalada xajinta | -20℃~60℃;<90% rh |
Cabbirka ugu badandanab | AC 1000V |
Dxoog koronto | 5.4kV rms |
Mfaas.awoodda lagu qiimeeyay | 300mVA |
Standeriyada | EN61010-1:2001, EN61010-031:2002, fasalka wasakhda2, CAT Ⅲ(600V), korantada ku meel gaadhka ah6000V |
Qaado kiis | 1pc |
Battery (LR6) | 2pcs |
Liiska baakad | 1 koobi |
Tilmaamaha Isticmaalaha | 1 koobi |
Warbixinta tijaabada warshadda | 1 koobi |