GD3126A (GD3126B) Tijaabada iska caabbinta dahaadhka 5kV/10TΩ (10kV/20TΩ)
GD3126A (GD3126B) Tijaabada iska caabbinta dahaarka waxaa si weyn loogu isticmaalaa dayactirka qalabka korontada ee substation transformer, warshad koronto, iwm. Waxay ku habboon tahay fulinta cabbirka caabbinta daaha (IR), saamiga nuugista (DAR), polarization index (PI), qulqulka hadda jira (Ix) iyo awoodda nuugista (Cx) ee dhammaan noocyada qalabka korantada sareeyo, oo ay ku jiraan beddelayaasha, Transformers, reactors, capacitors, matoorada, koronto-dhaliyeyaasha iyo fiilooyinka, iwm.
●Waxay qabataa kontoroolka kombuyuutarrada yar yar, hawlgalka menu-ka iyo bandhiga muraayadda shaashadda LCD-ga weyn oo leh waxqabad deggan.
●Awood xoog leh oo ka-hortagga faragelinta, oo ku habboon cabbirka jawiga faragelinta korantada ee xooggan.
●Awoodda weyn, waxay buuxin kartaa shuruudaha tamarta sare, caabbinta sare, tijaabada culeyska weyn ee awoodda.
●Iyada oo leh qaab-dhismeed aan shoog lahayn, qoyaan-celin iyo boodh, la qabso jawiga shaqada ee adag.
●Isticmaale saaxiibtinimo, muuji natiijooyin sax ah iyo isbeddelada xogta.
●Shaqada ilaalinta saxda ah, awood u leh inay u adkeysato saameynta wareegga gaaban iyo tamarta haraaga awoodda la qiyaasay.
●5 tallaabo wax soo saarka danab oo ah 250 V, 500V, 1.0kV, 2.5kV, 5.0kV.
●6 tallaabo wax soo saarka danab oo ah 250 V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV.Korontada sare ee tallaabo kasta si joogto ah ayaa looga hagaajin karaa eber.
●Korontada sare ee soo baxda ayaa sidoo kale si joogto ah loo hagaajin karaa.
●Cabbirka tooska ah ee R15, R60, R600, xisaabinta tooska ah ee saamiga nuugista, index polarization.
●Cabbirka cabbiraadda ugu badan ee iska caabbinta waa 0 ~ 10TΩ (0 ~ 20TΩ), baaxadda beddelka tooska ah.
●Si otomaatig ah loo cabbiro heerkulka deegaanka, qoyaanka hawada iyo wakhtiga tijaabada.
●Soo bandhiga wakhtiga tijaabada, talooyinka guuxa 15 ilbiriqsi kasta, 5 daqiiqo oo aan qallin ayaa soo dadajin doonta.
●Si toos ah u soo bixi danab sare ka dib cabirka la dhammeeyo, wakhtiga sii dayntu kama badna 30 ilbiriqsi.
●Kaydinta 60 kooxood oo natiijooyinka cabbiraadda, isbeddella'aan muddo 20 sano ah.
●Iyada oo leh RS232 serial interface, oo awood u leh in lagula xiriiro xogta kombiyuutarka.
●Daabacaha dibadda, wuxuu daabici karaa natiijooyinka cabbiraadda.(ikhtiyaar)
●Qulqulka muunada la dallacay waxa la tusaa ka hor inta aan la tijaabin waxana uu leeyahay tilmaamo khuseeya.
●Waqtiga tijaabada la sii dajiyay, si toos ah u jooji cabirka;
●Awood u leh inuu ogaado qulqulka Ix hadda iyo awoodda nuugista Cx.
Tallaabooyinka danabka tijaabada lagu qiimeeyay | GD3126A (5kV) GD3126B (10kV) | ||||||
250V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV | |||||||
Cilad koronto oo soo baxday | ± 5% | ||||||
Baaxadda iska caabinta | Xadka sare | 500GΩ~10TΩ | |||||
Xadka hoose | 0.1MΩ | ||||||
Heerka saxda ah | 5.0 fasalka | ||||||
Cilad muujinta danab sare | ±( 5%•Ux + 1digital) | ||||||
Kala duwanaanshaha cabbirka Ix ee hadda socda & khalad | 0.1nA ~ 9.9mA 5% | ||||||
AAwoodda bsorption Cx cabbiraadda baaxadda & khaladka | 0.1pF ~ 99ɥF 5% | ||||||
Khaladka cabbiraadda heerkulka | ±0.5℃ | ||||||
Khaladka cabbiraadda qoyaanka | ± 2% RH | ||||||
Wareegga gaaban hadda | <6mA | ||||||
Voltage ripple | <3% | ||||||
Waqtiga tijaabada | Ilaa 99 daqiiqo | ||||||
Iska caabin dahaarka | > 500 MΩ (inta u dhaxaysa siliga tijaabada iyo kiis) | ||||||
U adkeyso danab | AC10.0kV 50Hz 1min (inta u dhaxaysa siliga tijaabada iyo kiis) | ||||||
Korontada | 12V batari lithium ah | ||||||
Waqtiga adeegga batteriga ka dib hal dallac | 30 maalmood 10 jeer DAR & 5times PI test maalintii | ||||||
Heerkulka shaqada iyo qoyaanka | 0℃ ~ + 40℃ < 85% RH | ||||||
Heerkulka iyo qoyaanka kaydinta | -20℃ ~ + 50℃ <90%RH | ||||||
Bixinta Korontada | 220V AC 50Hz | ||||||
Cabirka (mm) | 325 (L)*250(W)*130(H) | ||||||
Miisaanka | 3.7kg | ||||||
Khaladka cabbiraadda iska caabinta | |||||||
Tallaabooyinka korantada | 250 V | 500 V | 1.0 kV | 2.5 kV | 5.0 kV | 10KV | |
± ( 3%·Rx + 1d) | 1GΩ | 2GΩ | 4GΩ | 10GΩ | 20GΩ | 40GΩ | |
± ( 5%·Rx + 1d) | 10GΩ | 20GΩ | 40GΩ | 0.1TΩ | 0.2TΩ | 0.4TΩ | |
± ( 10%·Rx + 2d) | 100GΩ | 200GΩ | 0.4TΩ | 1TΩ | 2 TΩ | 4TΩ | |
± ( 25%·Rx + 2d) | 500GΩ | 1TΩ | 2TΩ | 5TΩ | 10TΩ | 20TΩ |
Tijaabada iska caabbinta dahaarka | 1 set |
Tijaabi fiilada isku xidha ee L terminal (cas) | 1 xidid (1 xabbo) |
Tijaabi fiilada isku xidha ee G terminal (cagaar) | 1 xidid (1 xabbo) |
Tijaabi fiilada isku xidha ee E terminal (Madaw) | 1 xidid (1 xabbo) |
3Awood ada adabtarada ( Loogu talagalay sahayda korantada daabacaha iyo ku dallacaadda qalabka) | 1 piece (1 xabbo) |
RS232 Taxane khadka isgaarsiinta | 1 xidid (1 xabbo) |
Isticmaale'hagaha | 1 koob (1 xabbo) |
Warbixinta Imtixaanka | 1 koob (1 xabbo) |
1. L terminal socket 2. G terminal socket 3. E terminal socket 4. LCD screen
5. Buzzer 6. Heerkulka & dareeraha qoyaanka 7. Badhanka ESC 8. badhanka kor
9. Badhanka isbarbardhiga 10. Badhanka DOWN 11. badhanka OK12. Kubbadda hagaajinta tamarta sare
13. RS232 interface 14. Furaha korontada15. dallacsiinta godka