GDHX-9500 Baadhaha Wajiga
GDHX-9500 Wajiga Baaraha waxaa inta badan loo isticmaalaa xadhkaha korantada, wejiga iyo isku xigxiga isku xigxiga ee substation-ka, oo leh hawlo muhiim ah oo ay ka mid yihiin kormeerka korantada, cabirida wajiga iyo cabbiraadda isku xigxiga wejiga.Waxay isticmaashaa gaashaanka labanlaabka ah iyo calaamad cusub oo wareegyo dhijitaal ah, oo leh faragelin adag oo ka hortag ah, oo ay ku jirto heerarka EMC, oo ku habboon xaaladaha kala duwan ee faragelinta korantada.
Calaamadaha wajiga korantada sare ee rasaasta la qiyaasay si toos ah ayaa loo gudbin doonaa daawaynta ka dib, telefoonku wuxuu heli doonaa oo samayn doonaa isbarbardhigga wajiga, go'aamina natiijada ka dib ogaanshaha wajiga, farqiga xagal-waqtiga dhabta ah iyo vector.It isticmaalaa technology gudbinta wireless, ammaan ah oo la isku halayn karo. , dhakhso badan oo sax ah, ku habboon isticmaalka heerarka tamarta kala duwan (6V-500KV).Marka la hubinayo qaab dhismeedka shabakada, waxay awood u leedahay inay si sax ah u aqoonsato marxaladda qaraabada ah ee hogaaminta kala duwan ee saddexda weji ee isku xiran, iyada oo aan wax koronto ah oo u dhexeeya laba qaybood oo cabbir ah, taas oo ka dhigaysa codsiga qalabka cabbirka mid aad u jilicsan oo ammaan ah.
●Isticmaalka tignoolajiyada gudbinta wireless-ka, mabda'eeda shaqo ee aasaasiga ah waa isbarbardhigga marxaladda dhabta ah.
●Fadlan ilaali oo raac sharciga si aad u isticmaasho alaabtan, si aad u hubiso in qalabka si badbaado leh u shaqeeyo, cidhifyada X iyo Y looma ogola inay sameeyaan tijaabada korantada.
●Qaybaha madaxa birta ah ee usha dahaarka ayaa si adag loo mamnuucay inay la xiriiraan shay kasta inta lagu jiro tijaabada.
●Fadlan u hoggaansan shuruucda badbaadada warshadaha tamarta qaranka ee baaritaanka ka hortagga ee qalabka iyo alaabada badbaadada.
●Fadlan fiiro gaar ah u yeelo tababarka iyo imtixaanka shaqaalaha ka shaqeeya khadadka tooska ah ee korantada ama meelaha u dhow xadhkaha-voltage-ka.
●Qalabaynta wajiga ee qalabka nool waa in lagu fuliyaa usha dahaarka ah.
Fiiro gaar ah: Dhererka isticmaalka badbaadada leh iyo heerarka tijaabada ee usha dahaarka ee "Wireless Wajiga Detector".
(laga soo xigtay "Xeerarka shaqada badbaadada korantada ee Shirkadda State Grid".)
1. Fogaanta badbaadada ee u dhaxaysa shaqaalaha iyo jidhka la dalacsiiyay inta lagu jiro hawlgalka tooska ah.
Heerka Voltage | 10kV | 35kV | 66kV | 110kV | 220kV | 330kV | 500kV |
Fogaanta Badbaadada | 0.4M | 0.6M | 0.7M | 1.0M | 1.8M | 2.2M | 3.4M |
2. Dhererka dahaadhka ugu yar ee waxtarka leh ee usha dahaadhka ah inta lagu jiro hawlgalka tooska ah.
Heerka Voltage | 10kV | 35kV | 66kV | 110kV | 220kV | 330kV | 500kV |
Min.dhererka dahaarka waxtarka leh | 0.7M | 0.9M | 1.0M | 1.3M | 2.1M | 3.1M | 4.0M |
Fiiro gaar ah: Heerka tijaabada qalabka dahaarka hubinta tijaabada (qayb-hoosaadka): codsanaya soo noqnoqoshada awoodda 75kV kasta 300mm 1min, haddii aan burburay, aan flashover iyo kulayl ka badan, waxaa loo arkaa in ay u qalmi.
●Korantada tijaabada: 10V-500kV, oo ku habboon heerka korantada ee kala duwan.
●Saxnimada: khalad is-xakamaynta ≤±3°.
●Xawaaraha muunad: 10 jeer/s
●Taariikhda iyo wakhtiga dejinta: taariikhda iyo wakhtiga hagaajinta, u fududahay isticmaalayaasha si ay u baadho, u arkaan xogta taariikhiga ah.
●Dejinta wakhtiga iftiinka dambe: caadiyan shid, caadiyan dansan, 0-999s waxa dejin kara isticmaale.
●Deminta dabka tooska ah: 0-999mins waxa dejin kara isticmaale.
●In-wejiga: ≤20° waxa loo tixgaliyaa in uu yahay in-wajiga (marxaladda u dhaxaysa 0-90°, waxa dejin kara isticmaalaha. Nidaamku waa 20°.)
●Tayada kabaxsan wejiga:>20° (marxaladda marxaladda 0-90°, waxa dejin kara isticmaale. Nidaamka caadiga ah waa 20°.)
●Shaqada hagaajinta goobta: hagaajinta goobta ee rasaasta la qiyaasay, hubi saxnaanta xagasha wajiga.
●Fogaanta gudbinta ee u dhaxaysa taleefanka gacanta iyo X, qalabka Y: X≤150m, Y≤150m.
●Naqshad habab badan, oo leh ku habboonaansho xooggan, ka badbaado badan oo ku habboon.
●Is dhexgalka aadanaha iyo kombuyuutarka gaarka ah, hawlgal fudud.
●Naqshadaynta anteenada FCC, calaamaduhu way ka xoog badan yihiin oo way fududahay in la dhex geliyo xannibaadda gidaarka, albaabka, ama xannibaadda.
●Difaaca labajibaaran, faragelin adag oo an-ti ah, oo si buuxda waafaqsan heerarka EMC.
●Shaxda iyo soo bandhigida xogta, ka sahlan oo sahlan in la akhriyo.
●Cabbir tayo leh, oo lagu soo bandhigo dhawaaqa iyo calaamada iftiinka.
●Cabbirka tirada, farqiga xagal soo bandhiga wakhtiga-dhabta ah, khalad≤5°.
●Isku xigxiga wejiga, isku xigxiga wejiga togan, isku xigxiga wejiga taban (120°, 240°).
Tijaabi danab | 10V-500kV |
Korontada | Gacanta gacanta: No.5 AA baytari alkaline 2 qaybood (1.5V) |
Qalabka X iyo Y: No.7 AA baytari alkaline 2 qaybood (1.5V) | |
Fogaanta gudbinta wireless-ka | Masaafada muuqaalka 150m |
In-wejiga | Wejiga xagasha ≤20° (xadka u dhexeeya 0-90°, waxa dejin kara istimaal iskii.) |
Marxalad ka baxsan | Wejiga xagasha xagal>20° (xadka u dhexeeya 0-90°, waxa dejin kara istimaal iskii.) |
Muujinta saxnaanta | Cabbirka tirada≤3° |
Xallinta xagasha wejiga | 1° |
Qiyaasta isku xigxiga wejiga | Iyada oo loo marayo 120° saacada u jeedka/240° kahor saacada-saacda si loo go'aamiyo loona muujiyo isku xigxiga wajiga |
Bandhig | Bandhig LCD ah oo togan, oo si cad uga muuqda qorraxda hoosteeda |
heerkulka hawlgalka | -35℃-+50℃ |
Heerkulka kaydinta | -40℃-+55℃ |
Qoyaanka qaraabada | ≤95%RH, Aan-condensate ahayn |
Qalabka gacanta | 0.31kg |
Qalabka X | 0.13kg |
Qalabka Y | 0.13kg |