GD3127 Taxanaha Heerka Sare ee Iska caabbinta Korontada
GD3127 Taxanaha Insulation Resistance Tester waxaa si weyn loogu isticmaalaa dayactirka qalabka korontada ee substation transformer, warshad koronto, iwm. Waxay ku habboon tahay fulinta cabbiraadda caabbinta dahaarka (IR), polarization index (PI), nuugista saamiga (DAR), ramp ( RAMP), filter (FR, 10s, 20s, 30s, 40s 4 choices), danab (V), hadda (nA) ee dhammaan noocyada qalabka danab sare, oo ay ku jiraan beddelashada, Transformers, reactors, capacitors, matoorada, koronto-dhaliyeyaasha iyo fiilooyinka, iwm.
Taxanaha GD3127 waa aaladda ugu fiican ee tijaabinta hore ee aqoonsiga iyo ogaanshaha qorshayaasha dayactirka kahortagga ama saadaalinta ee cilladaha aaladaha iman kara.Waa muhiimad weyn in la hubiyo tayada badeecada iyo badbaadada dadka iyo qalabka shaqada.Waxqabadka xargaha ee alaabada korantada ayaa ah mid ka mid ah calaamadaha muhiimka ah ee lagu qiimeeyo tayada dahaarka, taas oo ka muuqata tijaabada caabbinta xakamaynta.
●Max.wakhtiga gaaban>5mA.
●Iska caabbinta dahaarka (IR), index polarization (PI), saamiga nuugista (DAR).
●Ramp (RAMP), filter (FR), danab (V).
●Si toos ah ula soco tamarta nool ee shayga la cabbiray, oo si toos ah u mamnuuc tijaabada haddii danabku dhaafo 36V, kaas oo si wax ku ool ah u ilaalinaya qalabka iyo hawlwadeenka.
●Shaqada wakhtiga, si toos ah u duub wakhtiga imtixaanka.
●Si toos ah u soo bixi danab sare ka dib cabirka la dhammeeyo, wakhtiga sii dayntu kama badna 30 ilbiriqsi.
●Si otomaatig ah u shaqeynta korontada
●Muujinta dhibcaha shaashadda weyn ee LCD oo leh waxqabad deggan.
●Qaab dhismeedka qolof-lakabka ah, adag oo waara, heerka ilaalinta IP65.
●Baakidhka baytariyada lithium ee awoodda weyn dib loo dallaci karo.
●Shaqada kaydinta, waxay si otomaatig ah u kaydin kartaa 1000 qaybood oo xogta imtixaanka wakhtiga-dhabta ah leh taariikhda iyo wakhtiga iyo wakhtiga tijaabada.
●Soo dejinta, oo ku qalabaysan interface USB, xogta diiwaanka waxaa lagu dhejin karaa kombuyuutar si loo baaro xogta xogta.
Shaqada | Iska caabinta dahaarka (IR), index polarization (PI), saamiga nuugista (DAR), ramp (RAMP), filter (FR, 10s, 20s, 30s, 40s 4 choices), volta (V), hadda (nA) |
Korontada | Dib loo buuxin karobaytari lithium5.2 ah |
danab la qiimeeyay | GD3127: 250V, 500V, 1kV, 2.5kV, 5kV GD3127B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV |
Korontada wax soo saarka asax | (5%-10%)±10V |
Cabbirka cabbirka caabbinta dahaarka | GD3127:0.50MΩ~2.00TΩ GD3127B: 0.50MΩ~5.00TΩ |
Wareegga gaaban hadda | >5mA |
Tusmada kala-soocidda (PI) | Haa |
Saamiga nuugista (DAR) | Haa |
Habka tijaabada ee Ramp(RAMP). | Ku tijaabi tillaabooyinka 10% ee danabkii hore loo dhigay ilaa korantada la sii dajiyay |
Shaandhee qaabka tijaabada | Afar doorasho oo ah 10S, 20S, 30S, 40S |
Tijaabada korantada | Xadka: AC/DC 0V-1000V, saxsanaanta:±5%rdg±3V |
Imtixaanka hadda | Xadka: 0.01nA-7mA, saxsanaanta:±5%rdg±0.5nA |
Kormeeraha korantada | La soco korontada shayga la tijaabiyay, la soco xaalada ka sii daynta tijaabada ka dib, oo mamnuuc tijaabada marka danabku ka weyn yahay 36V, ilaali qalabka iyo hawlwadeenka |
Tijaabada saacada | Si otomaatig ah u duub wakhtiga tijaabada, wakhtiga kala duwan: 0s~9999kii |
Kaydinta | Kaydinta tooska ah ee xogta tijaabada leh taariikhda iyo wakhtiga, wadar ahaan 1000 kooxood |
Isgaarsiinta | Ku soo rar xogta tijaabada ee kaydsan kombuyuutarka iyada oo loo marayo khadka isgaarsiinta USB. |
Battery | Waxa jira bandhig heer batari ah, oo xasuusinaya in lagu dallaco wakhtiga uu danabku yar yahay |
Shaqada daminta tooska ah | Si otomaatig ah u dami 15 daqiiqo ka dib |
Heerka ilaalinta | IP65/IP40 |
Iska caabin dahaarka | 50MΩ(1000V) (inta u dhaxaysa wareegga tijaabada iyo qolofka) |
U adkeyso danab | AC 3kV 50Hz 1 daqiiqo (inta u dhaxaysa wareegga tijaabada iyo qolofka) |
Heerarka | IEC61010-1, IEC61326-1 |
Heerkulka shaqada iyo qoyaanka | - 20℃ ~ +50℃ <80%RH |
Heerkulka iyo qoyaanka kaydinta | - 25℃ ~ +65℃80% RH |
Bixinta Korontada | 220V AC 50Hz |
Cabirka (mm) | 280(L)*260(W)*160 (H) |
Miisaanka | 4400g (oo ay ku jiraan baytari) |
Tijaabada iska caabbinta dahaarka | 1 set |
Siliga tijaabada danab sare (Casaan) | 1 gabal |
Tijaabi silig(Cagaar) | 1 gabal |
Tijaabisilig(Madow) | 1 gabal |
Adabtarka tamarta | 1 piece |
Isticmaale'hagaha | 1 koobi |
Tijaabirdhoofin | 1 koobi |