GD2000H 10kV Tijaabada iska caabbinta dahaadhka
Qalabkani waxa uu tijaabin karaa caabbinta dahaarka (sida Transformer, switchgear, lead, motor) ee qaybo kala duwan oo hal nidaam ah, si loo dahaadho loona dayactiro qaybaha fashilka.
Waxaa muhiim ah in la hubiyo tayada alaabta iyo amniga qofka iyo qalabka inta lagu jiro hawlgalka iyadoo la isticmaalayo tijaabada dahaarka ee hubinta shay shaybaarka dhulka ama ku xiga dahaarka.
Kahor tamarta nidaamka, isticmaal tijaabada dahaarka si aad u xaqiijiso haddii ay wanaagsan tahay in la hagaajiyo waxqabadka nidaamka.Tijaabada dahaarka waa in la helo dhibaatooyinka habka wax soo saarka iyo cilladaha qalabka oo aan la heli karin ka hor intaysan dhicin fashilka.Midowga Yurub, imtixaankani waa qasab, xitaa nidaamka madaniga ah.
1. Wax soo saarka Voltage GD2000H (5kV/10kV) .Cabbin kala duwan 0-400GΩ.
2. Laba hab ayaa muujinaya caabbinta dahaarka.
3. Si otomaatig ah oo xisaabinta saamiga nuugista iyo tusmada kala-soocidda.
4. Hawlgal saaxiibtinimo, badbaadin joogto ah natiijooyinka cabbirka 19times.
5. Si otomaatig ah u sii daaya tamarta sare ee hadhaaga ka dib markii imtixaanku dhamaado.
6. Korontada AC/DC, oo leh baytari dib loo dallaci karo ama adabtarada AC.
7. Awood xoog leh oo ka-hortagga faragelinta, xasilloon oo wax-akhris lagu kalsoonaan karo.
8. Naqshadaynta la qaadi karo, oo ku habboon shaqada duurjoogta ah.
9. Short-circuit hadda ≥3.5mA, qalabka ugu fiican ee lagu tijaabiyo caabbinta dahaarka ee transformer weyn, inductor, koronto, matoorada HV, capacitor koronto, fiilooyinka iyo xiritaanka qalliin.
ShaygaQaabka | GD2000H | ||
Korontada wax soo saarka | 5kV DC | 10kV DC | |
Saxnaanta | Heerkulka | 23℃±5℃ | |
Iska caabin dahaarka | 5M ~ 100G ±5% | 10M ~ 200G ±5% | |
Qiyaasta kale: ± 10% | |||
Korontada wax soo saarka | 40M ~ 200G 0 ~ + 10% | 80M-400GΩ 0 --+10% | |
Short-circuit hadda | ≥3.5mA | ||
Korontada | 8 *Nooca AA batari awood sare leh dib loo dallaci karo & adabtarada dibadda | ||
Heerkulka shaqada & qoyaanka | -10℃--40℃,max.qoyaan qaraabo 85% | ||
Heerkulka Kaydinta & Qoyaanka | -20℃--60℃,max.qoyaan qaraabo 90% | ||
Dahaarka | Max.20000MΩ marka danab u dhexeeya wareegga iyo qolofka waa 1000VDC. | ||
U adkeyso danab | U adkeyso 1min marka danab u dhexeeya wareegga iyo qolofka uu jiro3kV /50HzAC | ||
Cabirka | 230mm*190mm*90mm (L*W*H) | ||
Miisaanka | 3kg | ||
Agabka | Tijaabada tijaabada, buug-gacmeedka, adabtarada dib la buuxin karo, fiilada korontada, warbixinta tijaabada |
Tijaabada iska caabbinta dahaarka | 1set |
Tijaabi silig | 1 gabal |
Adabtarka tamarta | 1 gabal |
Xadhiga korantada | 1 gabal |
Tilmaamaha Isticmaalaha | 1 koobi |
Shahaado | 1 koobi |