GD2000D Tijaabada Iska caabinta Dahaarka
Tijaabada iska caabinta dahaadhka dhijitaalka ah ee GD2000D ee ay soo saartay shirkadeena waxay isticmaashaa nidaamka hawlgalka waqtiga-dhabta ah ee warshadaysanTilmaamaha analoogga dhijitaalka ah iyo soo bandhigida koodka goobta dhijitaalka ah ayaa si fiican la isugu daray.Taxanaha mitirku wuxuu leeyahay heerar wax soo saar oo danab ah oo kala duwan (250V, 500V, 1000V, 2500V, 5000V, 10000V), awood weyn, faragelin xoog leh, tilmaame analoog ah iyo muuqaal isku mid ah oo dhijitaal ah, AC iyo DC dual-isticmaalka, hawlgal fudud, Xisaabinta tooska ah ee tilmaamayaasha dahaarka kala duwan (saamiga nuugista, index polarization), natiijooyinka cabbiraadaha kala duwan ee leh shaqada hoos u dhigista awoodda, iwm. matoorrada danab, capacitors koronta, fiilooyinka korontada, iyo xirayaasha danabka.
DL/T 474-2006 "Hagaha tijaabada dahaarka ee goobta"
DL/T 845-2004 "Qeexitaannada guud ee cabbiraadda qalabka iska caabbinta"
DL/T 846-2004 "Qeexitaannada farsamada guud ee qalabka tijaabada tamarta sare"
DL/T 596-2005 "Koodhka tijaabada ka hortagga qalabka korontada"
GB50150-2006 "Heerka imtixaanka gacan-ku-galka ah ee qalabka korontada ku rakibida injineernimada"
GB/T16927.1 ~ 2-1997 "farsamooyinka tijaabada danabka sare"
GB4793-1984 "Iskuduwidda dahaarka ee gudbinta danab sare iyo qalabka qaybinta"
1. Wax soo saarka Voltage (250V/500V/1000V/2500V/5000V)
2. Laba hab ayaa muujinaya caabbinta dahaarka.
3. Si otomaatig ah oo xisaabinta saamiga nuugista iyo tusmada kala-soocidda.
4. Hawlgal saaxiibtinimo, badbaadin joogto ah natiijooyinka cabbirka 19times.
5. Si otomaatig ah u sii daaya tamarta sare ee hadhaaga ka dib markii imtixaanku dhamaado.
6. Korontada AC/DC, oo leh baytari dib loo dallaci karo ama adabtarada AC.
7. Awood xoog leh oo ka-hortagga faragelinta, xasilloon oo wax-akhris lagu kalsoonaan karo.
8. Naqshadaynta la qaadi karo, oo ku habboon shaqada duurjoogta ah.
9. Short-circuit hadda ≥3mA, qalabka ugu fiican ee lagu tijaabiyo caabbinta dahaarka ee transformer weyn, inductor, koronto, matoorada HV, capacitor koronto, fiilooyinka iyo xirida qalliin.
Shayga Lam. | GD2000D | ||||||
Korontada wax soo saarka | 250V DC | 500V DC | 1000V DC | 2500V DC | 5000V DC | ||
Saxnaanta | Heerkulka | 23℃±5℃ | |||||
Iska caabin dahaarka | 250-5G ±5% | 50-10G ± 5% | 1M-20G ±5% | 2.5M-50G ±5% | 5M-100G ±5% | ||
Qiyaasta kale: ± 10% | |||||||
Korontada wax soo saarka | 2M-10G ±5% | 4M-20G ±5% | 8M-40G 0--+10% | 20-100GΩ 0 --+10% | 40-200G 0-- +10% | ||
Short-circuit hadda | ≥3mA | ||||||
Korontada | 8*Nooca AA batari awood sare leh dib loo dallaci karo & adabtarada dibadda | ||||||
Heerkulka shaqada & qoyaanka | -10℃--40℃,max.qoyaan qaraabo 85% | ||||||
Heerkulka Kaydinta & Qoyaanka | -20℃--60℃,max.qoyaan qaraabo 90% | ||||||
Dahaarka | Max.2000MΩ marka danab u dhexeeya wareegga iyo qolofka waa 1000VDC. | ||||||
U adkeyso danab | U adkeyso 1min marka danab u dhexeeya wareegga iyo qolofka uu jiro3kV50Hz Sinedanab AC | ||||||
Cabirka | 230mm*190mm*90mm (L*W*H) | ||||||
Miisaanka | 3kg |
Tijaabada iska caabbinta dahaarka | 1set |
Tijaabi silig | 1 gabal |
Adabtarka tamarta | 1 gabal |
Xadhiga korantada | 1 gabal |
Tilmaamaha Isticmaalaha | 1 koobi |
Shahaado | 1 koobi |