GDYB-S20 Nidaamka Imtixaanka Meterka Tamarta ee Saddexda Waji
Taxanaha GDYB Saddex siman oo suurtagal ah oo shaqo badan oo awood badan oo mitir koronto ah Nidaamka Imtixaanka mitirka tamarta korantada ayaa si wanaagsan loo horumariyay jiilka saddexaad ee elektiroonigga ah ee barnaamijka saddex weji ee mitirka tamarta korantada ee nidaamka tijaabada shaqo badan sida waafaqsan heerarka iyo xeerarka qaranka ee ugu dambeeyay.Waxay qabataa dahaarka 0.01% saxnaanta sare ee 1: 1 tignoolajiyada wax beddelka ee hadda jira, si loo gaaro tijaabada korantada gudaha ku xiran shunt saddex weji mitir.Waxay ku habboon tahay tijaabinta mitirka tamarta korantada ee saddex weji oo kala duwan oo ah 0.2% iyo ka hooseeya (waxaa ku jira mitirka tamarta falcelinta sinusoidal).Waxay leedahay muuqaal wanaagsan, hawlo dhamaystiran iyo waxqabad aad u fiican.
GB/T 11150-2001 Qalabka tijaabada ee mitirka tamarta korantada (neq IEC 60736)
JJG 307-2006 Mitirka Electromechanical ee lagu Cabbiraayo Tamarta Korontada ee hadda jirta
JJG 596-1999 Mitirrada Tamarta Korontada ee Elektarooniga ah
JJG 597-2005 Qalabka Xaqiijinta ee mitirka Tamarta Korontada AC
DL/T 614-1997 Multifunction mitirka watthour
DL/T 614-2007 Qalabka korantada ee kala duwan
Xaalada deegaanka
Heerkulka deegaanka ee shaqaynaya: 23℃±2℃.
Ku shaqaynta qoyaanka deegaanka: 45%~75%
Korontada
Hal waji: AC220V± 33V.Inta jeer: 50± 2.5Hz
Nooca No.: GDYB-S20 Nidaamka Imtixaanka Meterka Tamarta ee Saddexda Waji.
Saxnaanta nidaamka: 0.05%.0.1%.
Saxnaanta mitirka caadiga ah: 0.05% mitirka caadiga ah ee saddex waji oo hawl badan.
Voltage & Cabbirka hadda jira:
Talaabada korantada soo saarida: 57.7V/100V/220V/380V.
Natiijada hadda jirta: 0.005A, 0.025A, 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 25A, 50A, 100A.
Soo saarida ugu yar ee hadda: 1mA.saxsanaanta: ≤5%.
Awoodda wax-soo-saarka (20 mitir)
Wax soo saarka korantada: 800VA.
Wax soo saarka hadda: 2500VA.
Voltage & hagaajinta hadda
Baaxadda la hagaajin karo: (0% ~ 120%) x cabbir cabbir.
Ganaax la hagaajin karo: 10%, 1%, 0.1%, 0.01%.
Hagaajinta wejiga:
Qiyaasta la hagaajin karo: 0° ~ 360°.
Ganaax la hagaajin karo: 10°, 1°, 0.1°, 0.01°.
Hagaajinta inta jeer:
Qiyaasta la isku hagaajin karo: 45Hz ~ 65Hz.
Ganaaxa la hagaajin karo: 1Hz, 0.1Hz, 0.01Hz.
Dejinta awoodda wax soo saarka: ≤0.05%/120S.
Korontada soo baxda & qallooca hadda:
Voltage: ≤0.5%.
Hadda: ≤0.5%.
Dejinta Harmonic:
Tirada harmonic: 2 ~ 21 jeer.
Waxyaabaha ka kooban: hadda 2 ~ 21 jeer ≤40% (marka loo eego hirarka aasaasiga ah).
danab 2 ~ 21 jeer ≤40% (marka loo eego hirarka aasaasiga ah).
Marxaladda Harmonic: 0°~359.99°.
Qalabka la socodka:
mitirka caadiga ah saxnaanta muujinta: Voltage: 0.01%.
Hadda: 0.01%.
Awoodda: 0.01%.
Marxaladda: 0.01.
Inta jeer: 0.01.
1:1 cabbirka beddelka ee hadda jira:
Saxnimada: 0.01%.
Awoodda soo saarista: 60VA.
Qiyaasta qiyaasta hadda: 1mA ~ 120A (1: 1).
Tusmada waxqabadka ugu weyn
a) Saxnimada: 0.01% (COS∮=0.5C…1…0.5L).
b) Inta jeer ee la qiimeeyay: 50Hz/60Hz±5%.
c) Hadda ugu horreeya: 3×0.001-120A.
d) Heerka sare: 3×0.001-120A.
e) Culayska wax soo saarka (weji kasta):
0.5W (qiyaastii wax soo saarka: 0.001-1A).
0.7V waxaa loo qaybiyaa qiimaha hadda (qiyaastii wax soo saarka: 1-120A).
f) Voltage load Output: Max.0.5V (wax soo saarka hadda ugu badnaan. 120A).
Cabbirka beddelka hadda: 265 x 200 x 240 mm (L x W x H).
Miisaanka: 12kg.
Cabirka:
Isha xakamaynta: 610 x 800 x 1920mm (L x W x H).
Rakibaadda mitirka: 2350 x 750 x 1850mm (L x W x H).