Alaabta

  • GDB-II Transformer rogmaday Tijaabada saamiga

    GDB-II Transformer rogmaday Tijaabada saamiga

    Marka loo eego IEC iyo halbeegyada qaranka ee khuseeya, tijaabada saamiga is beddelka waa shay ay waajib tahay in la sameeyo inta lagu jiro wax soo saarka, wareejinta isticmaaleyaasha, iyo tijaabada dib-u-habaynta korontadu.Tani waxay si wax ku ool ah u ilaalin kartaa tayada alaabada beddelka inta lagu jiro dhalmada iyo isticmaalka, waxayna ka hortagtaa wareegyada gaaban, wareegga furan, isku xirka khaldan ee u dhexeeya beddelka, iyo fashilka gudaha ama xiriirka cilladda beddelka.

    Sababtan awgeed, tijaabiyaha saamiga GDB-II ee ay soo saartay oo ay soo saartay shirkadeena ayaa ka dhigaysa hawlgalka mid fudud, dhammaystiran, xog sugan oo la isku halleyn karo, oo si weyn u wanaajisa xawaaraha tijaabada iyadoo loo eegayo shuruudaha isticmaalka goobta isticmaale ee asalka ah.Waxay daboolaysaa baahiyaha kala duwan ee tijaabooyinka saamiga beddelka saliidda ee waaweyn, dhexe, iyo yar yar.

  • GD6100D Tijaabada Saliida Tan Delta

    GD6100D Tijaabada Saliida Tan Delta

    Tijaabada ka-hortagga ah ee dahaarka qalabka korantada, cabbirka xilliyeed ee cabbirrada saliidda dahaadhka ee qalabka korantada ayaa loo baahan yahay.Cabbirka khasaaraha dielectric iyo caabbinta saliidda dahaadhka waa mid ka mid ah waxyaabaha ugu muhiimsan.Muddo dheer, intooda badan waxaa lagu qiyaasay habka buundada, oo ah mid adag in la shaqeeyo, iyo saxnaanta cabbirka waxaa saameeya arrimo badan, taas oo keentay khaladaad waaweyn oo cabbirka..

     

  • HV-OWS-63 Nidaamka Tijaabada Wave Oscillating (OWTS) ee Goobta PD ee Baadhista Xadhkaha

    HV-OWS-63 Nidaamka Tijaabada Wave Oscillating (OWTS) ee Goobta PD ee Baadhista Xadhkaha

    HV-OWS-63 Nidaamka Tijaabada Wave Oscillating (OWTS) ee Goobta Cilad-baadhista PD ee 10kV Cables waa goob dheecaan qaybeed isku dhafan iyo nidaamka maamulka.Inta jeer ee tijaabadu way kala duwan tahay 50Hz ilaa boqollaal Hertz oo hoos yimaada korantada AC.

    Waxa ay u ekaysiisaa xaalada socodka fiilada iyada oo adeegsanaysa danab, waxana ay keeni kartaa qayb dareere ah oo waxa ay ogaan kartaa xoojinta iyo meesha uu ku sugan yahay.Waxay isticmaashaa inductor godan oo taxane ah oo leh fiilada la tijaabiyay, waxayna ku dallacaa wareeggeeda taxanaha ah iyada oo loo marayo isha korantada sare ee DC.Marka korantada dallacadu gaadho qiime hore loo dejiyay, waxa ay xidhaysaa furayaasha elektarooniga ah ee ku xidhan isbarbar yaaca labada daraf ee isha korontada ciladaha dahaarka ee fiilada, iyo tayada dahaarka fiilada waxaa lagu xukumi karaa iyadoo la ogaanayo dheecaanka qayb ahaan.

     

     

  • GDW-106 Tijaabada Dhibabka Saliida

    GDW-106 Tijaabada Dhibabka Saliida

    Muddada dammaanadda ee taxanahan waa HAL sano laga bilaabo taariikhda shixnadda, fadlan tixraac qaansheegtaada ama dukumeentiyada rarida si loo go'aamiyo taariikhaha dammaanadda ee habboon.Shirkadda HVHIPOT waxay dammaanad qaadaysaa iibsadaha asalka ah in alaabtani ay ka xoroobi doonto cilladaha alaabta iyo shaqada ee isticmaalka caadiga ah.

  • GDQH-31W Qalabka Soo Celinta Gaaska ee La Qaadan Karo ee SF6

    GDQH-31W Qalabka Soo Celinta Gaaska ee La Qaadan Karo ee SF6

    GDQH-31W Laqaadan karo SF6 Qalabka Soo-kabashada Gaaska (MINI) waxaa loo isticmaalaa warshadaynta SF6 gaaska dahaaran qalabka korantada iyo hawlgalka & waaxaha cilmi-baarista sayniska si loogu buuxiyo qalabka korontada gaaska SF6 iyo ka soo kabashada SF6 gaaska qalabka korontada ee la isticmaalo ama la tijaabiyey.

    Isla markaana waa la sifeeyaa oo la cufan oo lagu kaydiyaa haanta kaydinta.Ku haboon shabakada qaybinta shabakada giraanta ka hooseeya 50kV.

      

     

     

     

  • GDYD-A AC Hipot Tijaabada Dejinta Cutub Koontorool Toos ah

    GDYD-A AC Hipot Tijaabada Dejinta Cutub Koontorool Toos ah

    Tijaabada AC hi-pot waa habka tooska ah ee waxtarka leh ee lagu tijaabiyo xoogga dahaarka ee qalabka korantada, qalabka ama mishiinnada.Waxay hubisaa cilladaha khatarta ah taasoo hubisa in qalabka korantada uu si joogto ah u shaqeeyo.

    Codsiyada caadiga ah waxaa ka mid ah tijaabinta Transformers, switchgear, fiilooyinka, capacitors, matoorada hawada, lebenka baaldiyada kulul, dhalooyinka faakuumka iyo qalabyada kale ee la xiriira sida vacuum internation, bustayaal, xadhko, galoofyada, tuubada hydraulics, qalab koronto dhaliyayaasha.

     

     

  • GDHG-106B CT/PT Analyzer

    GDHG-106B CT/PT Analyzer

    GDHG-106B waa qalab multifunctional si gaar ah loogu talagalay in lagu falanqeeyo Transformers hadda iyo transformers danab ilaalinta ama isticmaalka cabbirka.Hawlwadeenku wuxuu kaliya u baahan yahay inuu dejiyo qiyamka tijaabada hadda iyo tamarta, qalabku wuxuu si toos ah kor ugu qaadi doonaa tamarta iyo hadda, ka dibna wuxuu muujin doonaa natiijooyinka imtixaanka waqti gaaban.Xogta tijaabadu waa la kaydin karaa, la daabici karaa, oo lagu shubi karaa PC iyada oo loo marayo interface USB.

  • GDWG-IV SF6 Gaaska Daadanaya (Taxane IR)

    GDWG-IV SF6 Gaaska Daadanaya (Taxane IR)

    GDWG-IV SF6Detector Gaas-ka-baxa waa bareeriyaha nooca cas ee infrared (teknoolajiyada NDIR).Waa muujinta OLED midabka iyo waqtiga-dhabta ah waxay muujinaysaa fiirsashada SF6.

  • GDWG-V SF6 Gas Detector (nooca IR, laba bandhig)

    GDWG-V SF6 Gas Detector (nooca IR, laba bandhig)

    GDWG-V SF6 Gas Leak Detector waa nooca dhuuban ee cas infrared (teknoolajiyada NDIR) oo leh muuqaal labajibaaran.Waa muuqaal INCELL TFT midabka iyo waqtiga-dhabta ah waxay muujinaysaa xoojinta SF6.

  • GDPDS-341 SF6 Dahaarka Korontada ee Gobolka Falanqeeyaha Guud

    GDPDS-341 SF6 Dahaarka Korontada ee Gobolka Falanqeeyaha Guud

    Waqtigan xaadirka ah, heerka korantada UHV ee 110KV iyo wixii ka sareeya waxay isticmaashaa SF6 gaas-dahaaran oo kuxiran GIS oo ah qalabka aasaasiga ah ee aasaasiga ah, qiimeynta heerka dahaarka gudaha GIS waxaa inta badan lagu gaaraa habka qayb ka mid ah ogaanshaha dheecaanka iyo habka falanqaynta kiimikada gaaska SF6 ee guriga iyo dibadda.

  • GDSF-411CPD SF6 Gaaska Falanqeeyaha Dhameystiran

    GDSF-411CPD SF6 Gaaska Falanqeeyaha Dhameystiran

    GDSF-411CPD SF6Falanqeeye dhammaystiran gaaska waa aalad la qaadi karo oo loogu talagalay in lagu cabbiro SF6barta sayaxa gaaska, daahirnimada iyo alaabta qudhuntay.

  • GDSF-311WPD 3-In-1 SF6 Falanqeeyaha Gaaska

    GDSF-311WPD 3-In-1 SF6 Falanqeeyaha Gaaska

    GDSF-311WPD (GDSF-411WPD) waa qalab ku haboon marka ay lagama maarmaan tahay in la tijaabiyo waxa ku jira biyaha, daahirsanaanta iyo burburka gaaska SF6.Xudunta u ah tijaabada dhibicda sayaxa waa dareemayaasha taxanaha DRYCAP® oo ay soo saartay shirkadda Finland Vaisala.

Fariintaada noo soo dir:

Halkan ku qor fariintaada oo noo soo dir