HV-OWS-63 Nidaamka Tijaabada Wave Oscillating (OWTS) ee Goobta PD ee Baadhista Xadhkaha
1. Taxanaha HV-OWS waa hab isku dhafan oo qayb ka mid ah tijaabada dheecaanka, inta badan loo isticmaalo ogaanshaha qayb ahaan dheecaanka fiilooyinka tamarta dhexdhexaadka ah.Inta jeer ee imtixaanka nidaamka waa 50Hz ilaa dhowr boqol oo Hz damping AC danab, danab AC danab ay soo saartay nidaamka inta lagu guda jiro habka imtixaanka gaari karaa 60kV, oo waxaa lagu daraa qalabka nidaamka horumarsan iyo software nidaamka ogaanshaha.
●Tignoolajiyada ugu dambeeyay ee koronto-dhaliyaha elektiroonigga ah
●Tignoolajiyada ugu dambeeyay ee xakamaynta laysarka
● Processor-ka signalka dhijitaalka ah ee horumarsan iyo farsamada shaandhaynta
●Tiknoloojiyada kontoroolka shabakada wireless-ka ee horumarsan.
2. Software-ka cabbiraadda iyo falanqaynta ayaa samayn kara falanqaynta xogta fog ee xaaladda shabakad.
3. Isku-xidhka hawlgalka Ingiriisiga buuxa, oo awood u leh inuu duubo qaab-dhismeedka korantada oscillating iyo qaab-dhismeedka signal-ka-soo-baxa qayb ahaan, iyo samaynta dhibco-waqtiga dhabta ah inta lagu jiro habka cadaadiska;
4. Si toos ah u muuji inta jeer ee, baaxadda iyo muunadeynta ballaca hirarka korantada.
5. Waxay si toos ah u baari kartaa fidinta qaab-dhismeedka mawjada ee calaamadda dheecaanka qaybeed ee la tijaabiyay.
6. Si toos ah u muuji qiimaha tijaabada luminta dielectric
7. Si otomaatig ah u samee khariidad qayb ka mid ah goobta daadinta oo soo saar warbixinno tirokoob, oo si toos ah u soo saar khariidadda tirakoobka qayb ka mid ah.
Korontada wax soo saarka | Ugu badnaan: ± 60kVugu sarreysa |
Kala duwanaanshaha soo noqnoqda oscillation | 20Hz ~ 850Hz |
Inductance | 1.0H ~ 2.1H (ikhtiyaar) |
Falanqaynta xogta | Falanqaynta gacanta, falanqaynta tooska ah (analoog iyo shaandhaynta dhijitaalka ah) |
Kala duwanaanshaha awoodda in la cabbiro | 0.05 ~ 5uF |
Ku dallaca tamarta sare ee hadda | 10mA |
Kala duwanaanshaha tijaabada dheecaanka qayb ahaan | 10pC ~ 200nC |
Saxnaanta cabbirka | ± 0.1pC (muunad 14bits) |
Xawaaraha hirarka | 50-300m/annaga |
Helitaanka saxnaanta | ±0.1m |
Helitaanka qalad | ≤1% × dhererka fiilada |
Ogaanshaha heerka PD | Sida laga soo xigtay IEC60270 |
PD helitaanka bandwidth | 100kHZ ~ 50MHZ si toos ah ama xulashada gacanta |
Qiimaha khasaaraha dielectric tan δ | 0.1% ~ 10% |
danab sahayda | 180V ~ 250V, AC 50Hz |
Heerkulka shaqada | -120 ℃ ~ + 60 ℃ |
Miisaanka | Qiyaastii 88kg |
Cabbirka | Dhexroor 650mm, Dherer 980mm |
Interface | WLAN (IEEE802.11g)/100M kaarka Ethernet |
Maya | Magaca | Qty. |
1 | HV-OWS-63 oscillating nidaamka tijaabada mawjada cutubka ugu muhiimsan | 1set |
2 | Kumbuyuutar buug-yaraha ah (oo leh tijaabada dareeraha qayb ahaan mowjad oscillating iyo nidaamka software falanqaynta) | 1set |
3 | Capacitor magdhow dibadda ah | 1set |
4 | Koronto-dhaliyaha cabbirka garaaca wadnaha oo sarreeya | 1set |
5 | Xadhkaha tijaabada tamarta sare | 1set |
6 | Fiilada isku xidha koronto-sare (isku xidhka capacitors magdhowga) | 1set |
7 | Koronto dhaliyaha garaaca wadnaha (hal cas iyo mid madow) | 2pcs |
8 | Xakamaynta fiilada iibka | 1pc |
9 | Xadhkaha isgaadhsiinta shabakada (oo leh deked shabakad ilaa nooca-c module) | 1pc |
10 | Silig dhulka | 1pc |
11 | Usha dhulka | 1pc |
12 | Xadhkaha korontada | 1pc |
13 | Xirmooyinka fiilada ee qalabyada | 1pc |
14 | Buugga hawlgalka | 1 koobi |
15 | Shahaadada/kaarka dammaanadda | 1 koobi |
16 | Liiska baakad | 1 koobi |