GDTL AC Nidaamka Imtixaanka Resonant ee koronto-dhaliyeyaasha
Nidaamka Tijaabada Resonant AC ee taxanaha GDTL ee koronto-dhaliyeyaasha waxaa loo isticmaali karaa iyadoo la hagaajinayo inductance ee reactor, ama habaynta habka shaqada ee inta jeer ee nidaamka si loo gaaro dhawaaq.Labada hab ayaa loo isticmaali karaa si loo gaaro dhawaaq.In geeddi-socodka kor u qaadista danab, haddii dhibic resonant leexdo, waxaa laga heli karaa si sax ah by habka hagaajinta soo noqnoqda ganaax, kaas oo hubinaya qiimaha Q sare oo hoos u awoodda awoodda iyo miisaanka mugga qalabka imtixaanka.
●Cabbir yar, miisaan ka fudud marka la barbar dhigo heerka korantada ee isku midka ah, koronto-dhaliyaha awooda isku midka ah AC wuxuu u adkeysanayaa qalabka tijaabada tamarta.
●Mabda'a horumarsan ee aaladda go'an oo dhan iyo soo noqnoqoshada cusub & tikniyoolajiyada wax-ka-beddelka inductance, si adag u hubiso soo noqnoqda tamarta koronto-dhaliyaha u adkeysaneyso shuruudaha tijaabada korantada.baaxadda codsiga.
●Ku qalabaysan 20Hz-300Hz isha koontaroolka doorsooma.Ilaalinta wanaagsan iyo qaabka mowjadda wax soo saarka, xasilloonida sare.Iyada oo leh qaab shaqo oo badan, fududahay in lagu shaqeeyo.
●Korontada 220V ama 380V, oo ku habboon soo saarista korantada goobta.
●Dhibcaha Max.Q waxaa si sax ah loo heli karaa habka ugu horreeya ee inductance modulation iyo habaynta soo noqnoqda ee dambe, si looga fogaado leexinta resonance sababtoo ah kor u qaadista tamarta;
●Qaabeynta dabacsan iyo kordhin xoog leh.Buuxi dhammaan shuruudaha tijaabinta shayga awoodda leh ee nidaamka korontada.
●Habka tijaabada soo noqnoqda awoodda ama qaabka tijaabada soo noqnoqda ee bedbeddela.
●Isticmaal badan, kharash-ool ah.
●Danab wax soo saarka la qiimeeyay: 0 ~ 50kV (RMS) ama ka hooseeya.
●Soo noqnoqda soo-saarka: 45 - 300Hz.
●Waveform: Wave seere saafi ah, THD ≤ 1%.
●Max.awoodda: 2000kVA ama ka hooseeya.
●Wareegga shaqada: si joogto ah u shaqeeya 15mins hal mar oo koronto buuxda ah.
●Qodobka tayada: 10 - 40.
●Dareenka hagaajinta inta jeer: 0.1HZ, xasillooni darro <0.05%.
●Korontada: 220V ama 380V ± 15%, 50HZ ± 5%.
GDTF- 100/50 | |
Korontada wax-soo-gelinta (V) | 380 |
Korontada wax soo saarka (kV) | 0- 50 |
Awoodda (kVA) | 100 |
Baaxadda codsiga | Dab-dhaliye--awoodda dhulka 0.07-0.13 μF |
10 kV (300 mm²) fiilada ≤ 1 km | |
Habaynta ugu muhiimsan | 50kV/1A Reactor go'an 1 set |
50kV/1A reactor la hagaajin karo 1 set | |
Qaybiye awood leh 50kV | |
GDTF-150/50 | |
Korontada wax-soo-gelinta (V) | 380 |
Korontada wax soo saarka (kV) | 0- 50 |
Awoodda (kVA) | 150 |
Baaxadda codsiga | Dab-dhaliye--awoodda dhulka 0.13-0.2 μF |
10 kV (300 mm²) fiilada ≤ 1.5 km | |
Habaynta ugu muhiimsan | 50kV/1.5A Reactor go'an 1 set |
50kV/1.5A reactor la hagaajin karo 1 set | |
Qaybiye awood leh 50kV | |
GDTF- 225/50 | |
Korontada wax-soo-gelinta (V) | 380 |
Korontada wax soo saarka (kV) | 0- 50 |
Awoodda (kVA) | 225 |
Baaxadda codsiga | Dab-dhaliye--awoodda dhulka 0.2-0.27 μF |
10 kV (300 mm ²) fiilada ≤ 2.5 km | |
Habaynta ugu muhiimsan | 50kV/1.5A Reactor go'an 2 qaybood |
50kV/1.5A reactor la hagaajin karo 1 set | |
Qaybiye awood leh 50kV | |
GDTF- 360/60 | |
Korontada wax-soo-gelinta (V) | 380 |
Korontada wax soo saarka (kV) | 0- 60 |
Awoodda (kVA) | 360 |
Baaxadda codsiga | Dab-dhaliye--awoodda dhulka 0.27-0.33 μF |
Habaynta ugu muhiimsan | 60kV/2A Reactor go'an 1 set |
60kV/2A reactor la hagaajin karo 1 set | |
Qaybiye awood leh 60kV |