GDWG-V SF6 Gas Detector (nooca IR, laba bandhig)
GDWG-V SF6 Gas Leak Detector waa nooca dhuuban ee cas infrared (teknoolajiyada NDIR) oo leh muuqaal labajibaaran.Waa muuqaal INCELL TFT midabka iyo waqtiga-dhabta ah waxay muujinaysaa xoojinta SF6.Waxay si degdeg ah u ogaataa jabiyaha SF6, barta GIS ee daadinta iyo heerka daadinta sannadlaha si tayo iyo tiro ahaanba ah.Waa qalab wanaagsan oo ku habboon waaxda korontada, rakibidda iyo hagaajinta, machadka tijaabada korantada.
●Qalabka Bedelka Korantada Sare
●Rotor vane helicopter ah
●Nidaamka gudbinta gaaska
●Si loo ogaado dabdemiska
●Cilmi-baarista hufnaanta hawo-qaadista ee Dhismayaasha
●Si loo ogaado khatarta
●Shucaac ma laha.
●Looma baahna in la beddelo cadaadiska sare ee gaaska argon saafi ah si joogto ah.
●Looma baahna in loo dhawaado gaaska cadaadiska sarreeya.
●Looma baahna in la beddelo dareemayaasha si joogto ah, kharash-ool ah.
●Waxqabadka xasilloon, kharashka dayactirka oo hooseeya.Looma baahna in la sameeyo cabbir toosan sannad kasta.
●Wax saamayn ah kuma laha qoyaanka iyo wasakhowga deegaanka.
●Dareen sare, ilaa 0.01ppmv.
●Marka daadinta halista ah ama fiirsashada gaasta SF6 ay gaadho 100%, ma wasakhayso ama dhaawacmi mayso.
●Midabka TFT In-Cell Shaashadda, bandhig labajibbaaran, muuqaal iftiinka qoraxda.
●Ku-dhismay baytari lithium.
●Qeylo dhaan isticmaale-ku qeexan oo leh dhawaaq iyo iftiin.
●Dareen sare iyo xasilooni wanaagsan.
●Xawaaraha cabbirka degdega ah, wakhtigu waa ilaa 3s.
●Heerkulka iyo magdhowga cadaadiska.
●Kaliya jawaabta gaaska SF6, maaha gaaska kale.
●Astaamaha cabbiraadda xidhiidhka aan gaaska ahayn waxay xaqiijiyaan in aanay sumoobin shiduhu ku dhici doonin wax kasta oo diiradda saaraya.
●Qolka heerkulka joogtada ah ee dareemayaasha ayaa hubin kara in shidmahu aanu yeelanin heer kul heerkul kasta oo deegaanka ah.
●Cabbir yar, fududahay in la qaado, ku habboon shaqada goobta.
●Iyada oo leh xargaha gaaska ee aan sibidhka lahayn, aad u raaxo badan in lagu qaado.
●Kaydinta xogta ilaa 100 kooxood.
●Aluminium khafiif ah oo leh qolof gaashaan oo buuxa.
●Xirmada dibedda waxay isticmaashaa balaastiig injineernimada, oo leh biyuhu-celiyaan, aan boodh lahayn.
●Mabda'a cabbiraadda: Dareemaha infrared aan kala firdhin (NDIR)
●Qiyaasta kala duwan: 0-2000ppmv SF6 ama 0-50ppmv
●Xallinta: 0.1ppmv ama 0.01ppmv
●Saxnimada: ± 2% FS (0-1000ppm)
●Khaladka ku soo noqnoqda: ≤± 1%
●Dareenka: 0.1ppmv
●Waqtiga jawaabta: ≤2s
●Waqtiga soo kabashada: ≤5s
●Xasilooni: ≤±20ppm, in ka badan 1000saacadood
●Bedelka eber: ≤±1% (FS/sanad)
●Cilad toosan: ≤±1%
●Heerkulka kaydinta: -20~+60℃
●Heerkulka shaqada: -20~+50℃
●Habka muunadda: Ku-dhismay bamka diaphragm elektromagnetic, nooca boos-ku-galka tooska ah, socodka ilaa 1L/daqiiqo.
●Korantada shaqaynaysa: 220VAC±10%, 50Hz Ama Li-batteri-ku-dhisan, 8saacadood oo shaqaynaya.
●Cabirka: 160×220×70mm, qoriga gacanta 106mm*170mm*120mm.
●Miisaanka: cutubka ugu weyn qiyaastii 1.5kg, qoriga gacanta ilaa 0.5kg