GLF-314 SF6 Gas Infrared Imaging Detector
● Soo bandhigida dareenka leh ee heerka daadinta gaaska wakhtiga dhabta ah.
● Qaabka infrared-ka ee gaaska wanaajiyey si loo ogaado gaas yar oo soo daadanaya.
● Nidaamka hawlgalka ee isku xidhan, naqshada UI ee la mid ah talefanka gacanta iyo tablet-ka ayaa u sahlaysa isticmaalayaasha inay bilaabaan.
● USB, WiFi, HDMI hababka gudbinta xogta badan.
● Muuqaal LCD wareeg ah oo cabbirkiisu sareeyo.
● Muuqaal-hele qaraar sare leh oo leh xagal la hagaajin karo oo iftiin dhalaalaya leh.
● Fudud, naqshad adag.
● Naqshadeynta ergonomic-daalka ka-hortagga.
● Sawir-qaade heerkulbeeg ah
● Adabtarada korontada
● Lithium-ion baytariyada iyo dabaylaha dib loo buuxin karo
● fiilada USB
● Fiidiyowga HDMI
●32G TF kaarka xusuusta iyo kaarka akhriyaha
● Buugga isticmaalaha
● Sanduuqa baakadaha
N0. | Walxaha | Tilmaamaha | |
1 | Baaraha iyo cabbirrada indhaha | Nooca baaraha | Qaboobininfrareddkiciyayaasha |
2 | Xallinta infrared | 384×288 | |
3 | fogeynta Pixel | 25μm | |
4 | Shaandhayso hirarka jawaabta bandpass | 7μm-8.5μm,9.5μm -12μm | |
5 | Dareenka kulaylka (NETD) | <0.1℃@30℃ | |
6 | Gaaska la ogaan karo | 7μm–8.5μm:CH4 9.5μm -12μm: SF6 | |
7 | Lens infrared | Muraayada caadiga ah(21.7°±2°)× (16.4°±2°) | |
8 | Diiradda infrared | Buug-gacmeed & baabuur | |
9 | Muujinta sawirka | zoom Dijital ah | 1 ilaa 10 jeer zoom dijital ah oo joogto ah |
10 | Heerka qaabka sawirka | 50Hz±1Hz | |
11 | xallinta bandhig | 1024×600 | |
12 | Shaashada soo bandhig | 5-inji taabashada, xallinta 1024×600 | |
13 | Daawashada | OLED soo bandhigid heer sare ah, 1024 x 600 pixels | |
14 | Qaabka muuqaalka | Habka infrared Habka kobcinta gaaska. Habka cabbiraadda heerkulka infrared. Habka iftiinka muuqda. Habka-sawir-ku-gudbinta. Habka isku-dhafka; | |
15 | Hagaajinta sawirka | Toos ah iyo iftiinka gacanta iyo hagaajinta isbarbardhigga | |
16 | Palette | 10 nooc + 1 isticmaale-qeexay | |
17 | Kamarada dhijitaalka ah | Goobta muuqaalku waxay la socotaa muraayadda infrared | |
18 | Nalalka LED-ka | Haa | |
19 | Cabbirka heerkulka iyo falanqaynta | Qiyaasta heerkulka heerkulka | 1 qalab:-20 - 150 ° C 2 qalab:100 - 650 ° C |
20 | Saxnaanta | ±3℃or ± 3%(Qaado qiimaha weyn, heerkulka deegaanku waa 15 ° C ilaa 35 ° C) | |
21 | Cabbirka heerkulka barta dhexe | Haa | |
22 | Cabbirka heerkulka barta la dhaqaajin karo | Waxay taageertaa 10 dhibcood | |
23 | Cabbirka heerkulka aagga la dhaqaajin karo | Waxay taageertaa 10 goobooyin iyo 10 leydi | |
24 | Cabbirka heerkulka xariiqa dhaqaaqi kara | Waxay taageertaa 10 sadar | |
25 | Meelaynta barta heerkulka sare iyo hoose | Taageer shaashad buuxda oo heerkulkeedu sarreeyo iyo mid hooseeya iyo meelaynta barta heerkulka sare iyo hoose ee aagga | |
26 | Cabbiraadda horudhaca | Ma jiro cabbir, barta dhexe, barta heerkulka ugu badan, barta heerkulka ugu yar, heerkulka celceliska | |
27 | Alaarmiga heerkulka | Alaarmiga midabka (khadadka isothermal): kor/hoos ka hooseeya heerarka heerkulka la cayimay, inta u dhaxaysa heerarka heerkulka la cayimay. Qaylo dhaanta shaqada ee cabbirka: qaylo-dhaanta la maqli karo (kor/hoos/inta u dhaxaysa heerarka heerkulka la cayimay). | |
28 | sixitaanka qiimaha la qiyaasay | Dhaqdhaqaaqa (0.01 ilaa 1.0 la dooran karo), heerkul muuqda, qoyaan qaraabo ah, heerkulka jawiga, fogaanta bartilmaameedka, magdhowga daaqada irdaha dibadda | |
29 | Kaydinta taariikhda | Dhexdhexaadinta kaydinta | Kaarka xusuusta TF ee la saari karo |
30 | Si joogto ah sawiro u qaado | 3 ilbiriqsi ilaa 24 saacadood | |
31 | Falanqaynta sawirka shucaaca buuxa ee asalka ah | Sawirada kulaylka shucaaca ee la keydiyay waa la tafatiran karaa oo lagu falanqeyn karaa kamarada | |
32 | Qaabka faylka sawirka | Sawirada caadiga ah ee JPEG, oo ay ku jiraan sawiro dhijitaal ah iyo xogta shucaaca oo buuxa | |
33 | Duubista fiidiyaha infrared radiometric | Duubista muuqaalka shucaaca ee wakhtiga-dhabta ah, *.Faylka cayriin waxa lagu kaydiyaa kaarka TF | |
34 | Duubista fiidiyaha infrared ee aan shucaac ahayn | *.avi video file, ku keydi kaarka TF | |
35 | Sharaxaada sawirka | Cod: 60 ilbiriqsi, oo lagu kaydiyay sawir Qoraal: Ku dar miis, kala dooro shaxanka la sii qeexay | |
36 | Muuqaalka fogaanta | Fiiri qulqulka fiidyaha wakhtiga dhabta ah Wi-Fiisku xirka. Ku xidh si aad u muujiso adigoo isticmaalaya interface-qeexidda sare ee HDMI; | |
37 | Xakamaynta hawlgalka fog | Ku xidh koontaroolka software-ka ee u go'ay Wi-Fi; | |
38 | Isgaarsiinta iyo hareeraheeda | interface | USB 2.0, Wi-Fi, HDMI |
39 | WIFI | Haa | |
40 | Maqal | Makarafoonka iyo ku hadaliyaha si loogu sharaxo codka sawirka iyo duubista fiidiyowga | |
41 | tilmaame laser | Haa | |
42 | GPS | Taageer meelaynta dayax-gacmeedka, macluumaadka goobta ayaa lagu kaydin karaa sawirka | |
43 | Korontada | Nooca baytari | Batari elektaroonik ah oo lithium ah oo dib loo dallaci karo |
44 | danab batari | 7.4v | |
45 | Waqti shaqo oo joogto ah | Wax aan ka yarayn 4 saacadood heerkulka qolka | |
46 | Korontada dibadda | Taageerada korontada dc12v dibadda | |
47 | Maamulka awoodda | Si otomaatig ah loo xidho ama shaashadda tooska ah loo demiyo, wakhtiga waxa laga dooran karaa marna, 5min, 10min, 30min | |
48 | La qabsiga deegaanka
| Heerkulka shaqada | -20-+50 ℃ |
49 | Heerkulka kaydinta | -40-+70 ℃ | |
55 | Tilmaamaha jirka | Miisaanka (aan batari lahayn) | ≤ 1.8 kg |
56 | Cabirka (H*W*L) | ≤185 mm × 148 mm × 155 mm (oo ay ku jiraan muraayadaha caadiga ah) | |
57 | Tripod Buur salka | Heerka,1/4"-20 |
● Soo bandhigida dareenka leh ee heerka daadinta gaaska wakhtiga dhabta ah.
● Qaabka infrared-ka ee gaaska wanaajiyey si loo ogaado gaas yar oo soo daadanaya.
● Nidaamka hawlgalka ee isku xidhan, naqshada UI ee la mid ah talefanka gacanta iyo tablet-ka ayaa u sahlaysa isticmaalayaasha inay bilaabaan.
● USB, WiFi, HDMI hababka gudbinta xogta badan.
● Muuqaal LCD wareeg ah oo cabbirkiisu sareeyo.
● Muuqaal-hele qaraar sare leh oo leh xagal la hagaajin karo oo iftiin dhalaalaya leh.
● Fudud, naqshad adag.
● Naqshadeynta ergonomic-daalka ka-hortagga.
●Maamulaha sawir-qaadaha kulaylka
● adabtarada korontada
●Lithium-Ion baytariyada dib loo buuxin karo iyo dabaysha
●Cable USB
●Fiidiyowga HDMI
●32G TF kaarka xusuusta iyo kaarka akhriyaha
●Buugga isticmaalaha
●Sanduuqa baakadaha
N0. | Walxaha | Tilmaamaha | |
1 | Baaraha iyo cabbirrada indhaha | Nooca baaraha | Qaboobininfrareddkiciyayaasha |
2 | Xallinta infrared | 384×288 | |
3 | fogeynta Pixel | 25μm | |
4 | Shaandhayso hirarka jawaabta bandpass | 7μm-8.5μm,9.5μm -12μm | |
5 | Dareenka kulaylka (NETD) | <0.1℃@30℃ | |
6 | Gaaska la ogaan karo | 7μm–8.5μm:CH4 9.5μm -12μm: SF6 | |
7 | Lens infrared | Muraayada caadiga ah(21.7°±2°)× (16.4°±2°) | |
8 | Diiradda infrared | Buug-gacmeed & baabuur | |
9 | Muujinta sawirka | zoom Dijital ah | 1 ilaa 10 jeer zoom dijital ah oo joogto ah |
10 | Heerka qaabka sawirka | 50Hz±1Hz | |
11 | xallinta bandhig | 1024×600 | |
12 | Shaashada soo bandhig | 5-inji taabashada, xallinta 1024×600 | |
13 | Daawashada | OLED soo bandhigid heer sare ah, 1024 x 600 pixels | |
14 | Qaabka muuqaalka | Habka infrared Habka kobcinta gaaska. Habka cabbiraadda heerkulka infrared. Habka iftiinka muuqda. Habka-sawir-ku-gudbinta. Habka isku-dhafka; | |
15 | Hagaajinta sawirka | Toos ah iyo iftiinka gacanta iyo hagaajinta isbarbardhigga | |
16 | Palette | 10 nooc + 1 isticmaale-qeexay | |
17 | Kamarada dhijitaalka ah | Goobta muuqaalku waxay la socotaa muraayadda infrared | |
18 | Nalalka LED-ka | Haa | |
19 | Cabbirka heerkulka iyo falanqaynta | Qiyaasta heerkulka heerkulka | 1 qalab:-20 - 150 ° C 2 qalab:100 - 650 ° C |
20 | Saxnaanta | ±3℃or ± 3%(Qaado qiimaha weyn, heerkulka deegaanku waa 15 ° C ilaa 35 ° C) | |
21 | Cabbirka heerkulka barta dhexe | Haa | |
22 | Cabbirka heerkulka barta la dhaqaajin karo | Waxay taageertaa 10 dhibcood | |
23 | Cabbirka heerkulka aagga la dhaqaajin karo | Waxay taageertaa 10 goobooyin iyo 10 leydi | |
24 | Cabbirka heerkulka xariiqa dhaqaaqi kara | Waxay taageertaa 10 sadar | |
25 | Meelaynta barta heerkulka sare iyo hoose | Taageer shaashad buuxda oo heerkulkeedu sarreeyo iyo mid hooseeya iyo meelaynta barta heerkulka sare iyo hoose ee aagga | |
26 | Cabbiraadda horudhaca | Ma jiro cabbir, barta dhexe, barta heerkulka ugu badan, barta heerkulka ugu yar, heerkulka celceliska | |
27 | Alaarmiga heerkulka | Alaarmiga midabka (khadadka isothermal): kor/hoos ka hooseeya heerarka heerkulka la cayimay, inta u dhaxaysa heerarka heerkulka la cayimay. Qaylo dhaanta shaqada ee cabbirka: qaylo-dhaanta la maqli karo (kor/hoos/inta u dhaxaysa heerarka heerkulka la cayimay). | |
28 | sixitaanka qiimaha la qiyaasay | Dhaqdhaqaaqa (0.01 ilaa 1.0 la dooran karo), heerkul muuqda, qoyaan qaraabo ah, heerkulka jawiga, fogaanta bartilmaameedka, magdhowga daaqada irdaha dibadda | |
29 | Kaydinta taariikhda | Dhexdhexaadinta kaydinta | Kaarka xusuusta TF ee la saari karo |
30 | Si joogto ah sawiro u qaado | 3 ilbiriqsi ilaa 24 saacadood | |
31 | Falanqaynta sawirka shucaaca buuxa ee asalka ah | Sawirada kulaylka shucaaca ee la keydiyay waa la tafatiran karaa oo lagu falanqeyn karaa kamarada | |
32 | Qaabka faylka sawirka | Sawirada caadiga ah ee JPEG, oo ay ku jiraan sawiro dhijitaal ah iyo xogta shucaaca oo buuxa | |
33 | Duubista fiidiyaha infrared radiometric | Duubista muuqaalka shucaaca ee wakhtiga-dhabta ah, *.Faylka cayriin waxa lagu kaydiyaa kaarka TF | |
34 | Duubista fiidiyaha infrared ee aan shucaac ahayn | *.avi video file, ku keydi kaarka TF | |
35 | Sharaxaada sawirka | Cod: 60 ilbiriqsi, oo lagu kaydiyay sawir Qoraal: Ku dar miis, kala dooro shaxanka la sii qeexay | |
36 | Muuqaalka fogaanta | Fiiri qulqulka fiidyaha wakhtiga dhabta ah Wi-Fiisku xirka. Ku xidh si aad u muujiso adigoo isticmaalaya interface-qeexidda sare ee HDMI; | |
37 | Xakamaynta hawlgalka fog | Ku xidh koontaroolka software-ka ee u go'ay Wi-Fi; | |
38 | Isgaarsiinta iyo hareeraheeda | interface | USB 2.0, Wi-Fi, HDMI |
39 | WIFI | Haa | |
40 | Maqal | Makarafoonka iyo ku hadaliyaha si loogu sharaxo codka sawirka iyo duubista fiidiyowga | |
41 | tilmaame laser | Haa | |
42 | GPS | Taageer meelaynta dayax-gacmeedka, macluumaadka goobta ayaa lagu kaydin karaa sawirka | |
43 | Korontada | Nooca baytari | Batari elektaroonik ah oo lithium ah oo dib loo dallaci karo |
44 | danab batari | 7.4v | |
45 | Waqti shaqo oo joogto ah | Wax aan ka yarayn 4 saacadood heerkulka qolka | |
46 | Korontada dibadda | Taageerada korontada dc12v dibadda | |
47 | Maamulka awoodda | Si otomaatig ah loo xidho ama shaashadda tooska ah loo demiyo, wakhtiga waxa laga dooran karaa marna, 5min, 10min, 30min | |
48 | La qabsiga deegaanka
| Heerkulka shaqada | -20-+50 ℃ |
49 | Heerkulka kaydinta | -40-+70 ℃ | |
55 | Tilmaamaha jirka | Miisaanka (aan batari lahayn) | ≤ 1.8 kg |
56 | Cabirka (H*W*L) | ≤185 mm × 148 mm × 155 mm (oo ay ku jiraan muraayadaha caadiga ah) | |
57 | Tripod Buur salka | Heerka,1/4"-20 |