GDJB-1200A Diyaarinta Imtixaanka Ilaalinta Isku-gudbinta ee Lixda Waji
●Wax soo saarka ilaa 6-waji danab 6-weji xaadir ah, kaas oo la isku dari karo si loo xaqiijiyo 4-waji danab 3-waji ah nooca hadda, 6-wajiga nooca danab, 6-wajiga hadda jira, iyo 12-wejiga wax soo saarka qaab.
●Kombiyuutarka xakamaynta warshadaha ee waxqabadka sare leh iyo 8.4-inji weyn oo shaashad ah oo leh midab sare oo midab leh oo TFT dareere ah, kaas oo ku siin kara macluumaad qani ah oo dareen leh, oo ay ku jiraan heerka shaqada ee hadda ee qalabka, talooyinka shaqada ee soo socda iyo macluumaadka caawinta kala duwan;
●Wax soo saarku waxa uu isticmaalaa cod-weyneeye koronto toosan oo heersare ah oo la isku halleyn karo, halkii uu ka isticmaali lahaa cod-weyneeye koronto nooca beddelka ah si loo helo waxqabad sare.Ma dhalin doonto faragelinta soo noqnoqoshada sare iyo dhexdhexaadka ah goobta imtixaanka, waxayna hubin doontaa qaabaynta mawjada wanaagsan iyo saxnaanta hadda sare ilaa hadda yar.
●Qaybta wax soo saarka waxaa gacanta ku haya DSP, kaas oo leh xawaaraha xisaabinta degdega ah, awoodda farsamaynta calaamadaha dhijitaalka ah ee waqtiga-dhabta ah, xawaaraha gudbinta iyo beddelka sare ee D / A.Qaabka mawjada wax soo saarka ayaa leh saxnaan sare, qallooc yar iyo toosnaan wanaagsan.Waxay qabataa tiro badan oo tignoolajiyada horumarsan iyo agabka saxda ah ee ka kooban, waxayna fulisay naqshad dhismeed xirfadeed.Sidaa darteed, qalabku waa mid yar oo cabbirkiisu yar yahay, miisaankiisu yar yahay, hawlihiisa buuxa, fududahay in la qaado, waxaana la shaqayn karaa marka la bilaabo, imtixaankuna waa mid aad u habboon.
●Waxay dhamaystiri kartaa tiro badan oo shaqo hubin adag oo baaxad leh oo leh heer sare oo otomaatig ah.Waxay si fudud u tijaabin kartaa oo u baadhi kartaa goobo ilaalineed oo kala duwan, waxay samayn kartaa dib-u-ciyaar khalad ah, waxay kaydin kartaa xogta tijaabada wakhtiga dhabta ah, soo bandhigta sawirada vector, iyo daabacaadda warbixinada khadka.
●Waxaa jira 110V iyo 220V madax banaan oo u go'an soo saarista korantada DC ee la hagaajin karo ee kormeerka goobta.
●Tijaabada jiilka cusub ee GDJB-1200A waxaa lagu qalabeeyaa furriinka 10-jidka ah iyo furitaanka 8-daad, taas oo ku habboon tijaabada is-mudidda.Xidhiidhka galitaanka waxa uu ku haboon yahay xidhiidh madhan iyo 0 ~ 250V xidhiidho suurtagal ah, kuwaas oo si caqli ah loo aqoonsan karo oo si toos ah loo aqoonsan karo.
●Waxa uu qaban karaa noocyo kala duwan oo hawlo isku dubarid adag, oo si fudud u tijaabin kara oo u sawiri kara goobaha ilaalinta kala duwan ee dib u ciyaarida qaladka.Ku kaydi xogta tijaabada wakhtiga dhabta ah, muuji sawirada sawirada, warbixinada daabacaadda, iwm.
●Qaab dhismeedka kuleylka kuleylka waxaa loo qaabeeyey si macquul ah, tallaabooyinka ilaalinta qalabka waa la isku halleyn karaa oo qumman, iyo shaqada bilawga jilicsan ee awoodda, is-ogaanshaha software iyo shaqada xannibista wax soo saarka ayaa la bixiyaa.
Soo-saarka AC Hadda | 6-waji (RMS) | 6*0~30A |
3-waji (RMS) | 3*0~60A | |
6-waji isbarbar socda wax soo saarka hadda (RMS) | 0 ~ 180A | |
La ogolaan karo wakhtiga dheer ee shaqada qiimaha wakhtiga xaadirka ah (RMS) | 10A | |
Awooda wax soo saarka ee ugu badan ee marxaladda hadda | 400VA | |
Saacadaha shaqada ee la ogol yahay @ max.wax soo saarka 6-waji isbarbar socda | 10s | |
Saxnaanta | ≤0.5A ±2mA >0.5A 0.2% | |
Kala duwanaanshaha soo noqnoqda (mawjada aasaasiga ah) | 0 ~ 1000Hz | |
Waqtiyo isku mid ah | 0-20 jeer | |
Soo-saarka DC ee Hadda | Wax soo saarka hadda | 0 ~ ± 10A/waji;0 ~ ± 60A/6-pahse is barbar socda |
Saxnaanta | 0.5% | |
Korontada culeyska wax soo saarka ee ugu badan | 20V | |
Soosaarka Voltage AC | Wax soo saarka tamarta wajiga (RMS) | 0 ~ 120V Saxnimada: 0.2% |
Wax soo saarka korontada ee khadka (RMS) | 0 ~ 240V | |
Wajiga korantada/Line koronto soo saarista | 80VA/100VA | |
Kala duwanaanshaha soo noqnoqda (mawjada aasaasiga ah) | 0 ~ 1000Hz | |
Waqtiyo isku mid ah | 1-20 jeer | |
Soosaarka Voltage DC | baaxadda wax soo saarka danab ee wajiga | 0~±160V Saxnimada: 0.5% |
baaxadda wax soo saarka danab line | 0 ~ 320V | |
Wajiga korantada/Line koronto soo saarista | 70VA/140VA | |
Binary | galinta binary | 10 kanaal |
Xidhiidh aan shaqayn | 1 ~ 20mA, 24V | |
Helitaanka xiriirka suurtagalka ah | "0": 0 ~+6V;"1": +11 V ~ +250 V | |
Wax soo saarka binary | 8 lammaane DC: 220 V / 0.2 A;AC: 220 V/0.5 A | |
Qiyaasta Waqtiga | 0.1ms~9999s Cabbirka saxnaanta: <0.1mS | |
Cabirka & Miisaanka | 480*360*200mm³ 19kg |
Maya | Magaca | Sharaxaada | Qty/Cutub | Sawir |
1 | Unugga ugu weyn | GDJB-1200A | 1set |
|
2 | Fuse | 2A | 4gabal |
|
10A | 4gabal | |||
3 | Xadhiga korantada |
| 1 gabal |
|
4 | Tijaabi silig | 0.5m (casaan, jaalle, cagaar, madow 2 xabbo) | 8 xabbo |
|
5 | Tijaabi siliga 4 xudunta ah | madow(casaan, jaalle, cagaar, madow)- fidsan | 2 xabbo |
|
6 | Tijaabi siliga 4 xudunta ah | madow(casaan, jaalle, cagaar, madow)-wareeg | 2 xabbo |
|
7 | Tijaabi silig | buluug | 1 gabal |
|
8 | Tijaabi silig | (caddaan, kafee 1 xabbo midkiiba) | 2 xabbo | |
9 | Tijaabi silig | casaan, cagaar, jaalle 1 gabal kasta) | 3 xabbo | |
10 | Tijaabi silig | madow | 2 xabbo | |
11 | Isgaarsiintasilig |
| 1 gabal |
|
14 | Isku dhejinta tijaabada weyn | (casaan, jaalle, cagaar, madow 1 xabbo) | 4 xabo |
|
15 | Xajin tijaabo yar | (jaalle, cagaar, midkiiba 4 xabbo) | 8 xabbo | |
16 | Xajin tijaabo yar | (cas, madow 5 xabbo) | 10 xabbo | |
17 | Sawir | (cas, jaalle, cagaar, madow 2 xabbo) | 8 xabbo | |
18 | Tijaabi irbadda | (cas, jaale, cagaar, madow 3 xabbo) | 12 xabbo | |
19 | CD |
| 1 koobi |
|
20 | Gudub QC | In English | 1 koobi |
|
21 | Buugga | In English | 1 koobi |