GD-2136H Nidaamka Helitaanka Cilad-xumada Cable
GD2136H Nidaamka Ciladda Cable waa qalab muhiim ah si loo ilaaliyo dhammaan noocyada fiilooyinka.Waxay isticmaashaa siyaabo kala duwan oo lagu ogaanayo si ay u tijaabiso cilladaha fiilooyinka, taas oo ku habboon heerarka kala duwan ee fiilooyinka korantada iyo fiilooyinka isgaarsiinta.
Nidaamku wuxuu ka kooban yahay cutubyo hoos ku qoran:
1. GD-2131H Matoor kicinta
2. GD-2132 Cable Cable Locator
3. GD-2133 Cable Cable Tijaabaha
4. Qalabka kale
GD-2131H Soo-saare kicinta
Waxaa loo isticmaalaa in lagu dhaliyo dareen-celinta HV marka la isticmaalayo habka flashover-ka si loo ogaado cilada impedance sare.
●Awood gubasho xoog leh, awoodda gubashada max.gu waa 1000W, barta burburku waa la gubi karaa waqti gaaban waxaana hoos u dhacaya iska caabinta barta burburka.
●Haddii si wadajir ah loola shaqeeyo GD-2133 Cable Fault Tester, waxaa jira laba siyaabood oo lagu helo:
a.garaaca garaaca hoose: Haddii kaliya la isticmaalayo GD-2133, wareegga furan iyo impedance hoose cilada dhulka ee fiilada waxaa la heli karaa, iyo dhererka fiilada waa la qiyaasi karaa ama xawaaraha hirarka fiilada waa la ogaan karaa.
b.Tooshka sare ee koronta: Qaabka mowjadda korantada garaaca wadnaha ee cilada waxa lagu muunadeeyay iyada oo la saarayo faraqa xajka, kaas oo ogaan kara fogaanta cilladda.
●Samee dareenka soo noqnoqoshada go'an.Haddii si wadajir ah loola shaqeeyo GD-2132 Cable Fault Locator, waxaa jira hawlo soo socda:
a.Habka maqalka waxaa loo isticmaalaa in lagu dhammaystiro goobta saxda ah ee guud ahaan caabbinta sare iyo dhibcooyinka cilladaha.
b.Si aad u tilmaamto dariiqa fiilada, aqoonso fiilada gaarka ah.
c.Burburka macdanaha ah (dhimashada dhulka), iyadoo la adeegsanayo cabbiraadda magnetic- field si loo helo si sax ah.
●Waxa kale oo loo isticmaali karaa in DC HV ee imtixaanka adkaysiga.
●Korontada wax gelinta: AC 220V,50Hz
●Korontada wax soo saarka: DC 0-32kV (la hagaajin karo)
●Awoodda la qiimeeyay: 2000VA
●Tamarta ugu badan: 2048J, 4uF
●Danab toosan oo DC ah: 32kV
●Xakamaynta tooska ah ee DC: 63mA
●Ugu badnaan hadda: 500mA
●Habka soo daynta: DC HV, hal mar, wareeg
●Waqtiga wareegga wareegga: 3-6 ilbiriqsi
●Heerkulka deegaanka:0-40℃
●Qoyaanka: <75% RH
●Joog:<1000m
●Heerka dahaarka: A
●Cabirka: 430*540*410mm
●Miisaanka: ilaa 31kg.
Oo ay ku jiraan gudbiyaha, qaataha, baadhitaanka kicinta, ogaanshaha nooca suurtagalka ahframe.Waxay ku habboon tahay in lagu tijaabiyo dhammaan noocyada fiilada korantada oo leh kaari macdan ah.
Shaqadeeda ugu weyn waa helitaanka barta dahaarka liidata, ogaanshaha wareegga iyoqoto dheer ee fiilada korontada.
●Dareen sare
●Socod fadhiid hooseeya
●Saxnaanta sare ee helitaanka
●Ka-hortagga faragelinta
●Shaashada LCD si ay u muujiso calaamadaha iyo heerka
●Ku dhex-dhismay baytari Li-batteri dib lagu dallaci karo
●Baafinta iyo meelaynta fogaanta: fiilada maxalliga ah 3km, fiilada kale ilaa 20km
●Helitaanka baaxadda xannibaadda: 0-5MΩ.
●Xaqiijinta goobta: ≤± 10cm.
●Qoto dheer ee fiilada ogaanshaha: <3m.
Waxa ay tijaabin kartaa khaladaadka ka iman kara isdhaafka-sare,-saredhulka iska caabinta, wareegga gaaban, fiilada goynta, xiriir xumodhammaan noocyada fiilooyinka korantada (degree voltaji 1kV-35kV),fiilada maxalliga ah, fiilada isgaarsiinta, fiilada coaxial iyo birta birta ah.
Waxay kaloo cabbiri kartaa dhererka fiilada iyo xawaaraha faafinta xawaaraha hirarka korantada ee fiilada.
●Imtixaan badbaado leh, degdeg ah oo sax ah.Waxay isticmaashaa habka dareenka LV iyo ogaanshaha HV flashover, kaas oo tijaabiya dhammaan noocyada cilladaha fiilada.Khaasatan bilicda iyo cilladaha sare ee fiilooyinka, si toos ah ayaa loo tijaabin karaa iyada oo aan guban;haddii lagu qalabeeyo goob cabbiraadda dhawaaqa, booska saxda ah ee cilada ayaa si sax ah loo go'aamin karaa.
●Isticmaalka tignoolajiyada muunada xogta xawaaraha sare.Xawaaraha muunad ee A/D waa 100Mhz, si loo sameeyo xallinta akhriska qalabku waa 1m halka aagga wax lagu ogaanayona uu yahay 1m.
●Foomka hirarka iyo xogta ayaa si toos ah ugu soo bandhigaya shaashadda weyn ee LCD.
●Foomka hirarka iyo kaydinta cabbirka, shaqada dib u yeedhista.
●Shaqada isbarbardhigga qaabka hirarka tijaabada ee cilladda fiilada iyo qaabka hirarka caadiga ah.
●Qaabka hirarka shaqada fidinta
●Si toos ah u tus meesha qaladka ah iyo barta imtixaanka fogaan toos ah ama fogaan qaraabo ah.
●Wax ka beddel xawaaraha faafinta wakhti kasta iyadoo loo eegayo fiilooyinka tijaabada ee kala duwan.
●Ku-dhismay baytari dib lagu dallaci karo.Cabbir yar, la qaadi karo.
●Masaafada ugu badan ee tijaabinta: 15km (Siliga furan ilaa 100km).
●Dareenka indho la'aanta: 1m
●Qaraarka: 1m
●Isticmaalka tamarta: 5VA
●Heerkulka deegaanka: 0-40℃(heerkulka xaddidan:-10℃-50℃)
●Qoyaanka qaraabada: 40℃(20~90) %RH
●Cadaadiska hawada: 86-106Kpa
●Cabbirka: 275*220*160mm
●Miisaanka: 1.8kg
Qalabka kale waxaa ka mid ah AF Stethoscope, Sameecado-dhegaha, Pin Grounding, PD Locating Rack, RF Tracking Rod.