GDCF-900T Baabuurka Ku Xidhan Kaabka Nidaamka Meelaynta Cilada
Baabuurta Ku Xidhan Cable Gault System waxa loo isticmaalaa qaboojinta Cilada Cable-ka (gubatay), Goobta Hore, Goobta Jidka, Pin-fiiqida & Tijaabinta fiilooyinka HV & LV ee noocyada & cabbirrada kala duwan.Qalabkani wuxuu ku habboon yahay in lagu fuliyo hawlaha kor ku xusan ee kor ku xusan ee fiilooyinka korantada ee heerarka kala duwan ee korantada inta badan 33KV, 11KV, 415V iyo fiilooyinka xakamaynta ee leh 1.1 KV.Qalabka waa in loo adeegsadaa noocyada fiilooyinka sida XLPE, PVC, PILC oo leh Al / Cu kaari.Xadhkaha waxa la dhigaa dhulka hoostiisa (dhul banaan hoostooda, godad, ama dusha RCC, Qodista Horizontal in HDD Pipe), ka sarraysa dhulka ama qayb hoosteeda & qayb ka saraysa dhulka oo leh dhererka fiilada ugu badan ee ku wareegsan 25Km.
Meeleeyaha cilladaha fiilada ayaa ku habboon in la helo cilladaha iyo tilmaamidda cilladaha fiilada ee soo socda.
●iska caabin sare
●iska caabin hoose
●Cilladaha biligleynaya nooca joogtada ah.
●Goobta qaladka galka
●Nidaamku waxa uu isticmaalaa garaacyo badan (hab milicsiga ARC), saddex jeer garaaca wadnaha, habka kicinta, habka flashover, habka TDR si loo sameeyo cabbir qallafsan ee dhammaan noocyada cilladaha fiilada.
●Waxay adeegsataa habka magnetic acoustic si ay si sax ah u hesho dhibcaha khaladka ah.
●Waxay isticmaashaa mabda'a kicinta korantada si ay ula socoto fiilada aan la garanayn oo ay u hesho qoto dheer ee fiilada.
●Aqoonso oo dalool fiilooyinka farabadan.
●Hel oo cabbir galka fiilada.
Nidaamka tijaabinta cilladaha fiilada ku rakiban baabuurku wuxuu adeegsadaa nakhshad dhammaystiran oo habaysan oo bini'aadminimo si loo helo cilada dahaarka ee fiilooyinka korantada ee 33KV, 11KV iyo 415V, ogaanshaha meesha qaladka ah ee galka dibadda, barta go'aaminta saxda ah, tijaabada wadada, aqoonsiga nool, daldal badbaadada , DC caabbinta in dhammaan noocyada qalabka tijaabada, qalabka qaybinta korontada, qalabyada iyo qalabka kaalmaha loo baahan yahay in lagu rakibo baabuurta gaarka ah ee la bedelay.
Dhammaan habka imtixaanku waa badbaado waana xiran yahay, iyo hawlaha imtixaanku waa kala duwan yihiin natiijooyinka imtixaankuna waa sax.
●Gaadhigu wuxuu ka kooban yahay saddex qaybood oo kala ah: Taabsiga, qolka qalliinka iyo qaybta qalabka.
●Naqshadeynta qalabka loo yaqaan 'console' waa mid macquul ah, iyo tijaabada dahaarka fiilada, xukunka hantida khaladka ah, iyo cabirka fogaanta qaladka ayaa si buuxda loogu dhammeyn karaa gaariga.
●Martigeliyaha tijaabada khaladku wuxuu dhamaystiri karaa cabbirka qallafsan ee masaafada cilada fiilada wuxuuna si toos ah u dhejin karaa booska.
●Qolka kantaroolka waxaa loogu talagalay qayb madax-bannaan oo awood sare leh oo korantada sare leh, LCD waxay soo bandhigaysaa waqtiga-dhabta ah ee hadda jira iyo korantada, si toos ah si caqli-gal ah u dhammaystiraan hawlgalka korantada sare iyo dareeraha.
●Aqoonsiga fiilada, martigeliyaha tijaabada marinka ayaa ku dhex jira qolka qalliinka.
●Miiska qalliinka waxa uu ka samaysan yahay resin epoxy si uu dhamaan u noqdo mid nadiif ah oo qurux badan.Khaanadaha qalabka waxaa loogu talagalay wax soo saarka birta iyo qufulka xadiidka ee sanqadha nuugaya.Waa mid waara, aan simbiriirixan lahayn, u adkaysta xidhashada oo si fudud loo xoqo.Waxay hubisaa badbaadada habka baaritaanka.
Qaab dhismeedka gudaha
1——Meesha baabuurka
2——Aagga hawlgalka
3——Cutubka kantaroolka dhexe
4——Habitaanka calaamadaha cilladda
5 - Golaha sunta mashiinka ee gaariga
6—— Qaybta tijaabada korantada sare
7—— unug ilaalin
8——Sameeye
9—— Gariiradda Tijaabada Voltage Sare
10—— Gariirada fiilada dhulka
11——Darbiga go'doonsan
Nidaamka oo dhan waxaa ka mid ah
Shayga | Magaca | Qaabka No. | Qty |
1 | Vmid ah | ----- | 1 |
2 | Tijaabada khaladka fiilada garaaca badan | GD-4133 | 1 |
3 | Isku-xidhaha garaaca wadnaha
| GD-4133S
| 1 |
4 | Ccilad awood leh
| GD-4132
| 1 |
5 | Hkoronto dhaliyaha danab-ku-oolka ah | GD-2131H
| 1 |
6 | Caqoonsan kara | GD-2134D
| 1 |
7 | Cqalab dalooli kara | GD-2135B | 1 |
GD-2131H Soo-saare kicinta
Waxaa loo isticmaalaa in lagu dhaliyo dareen-celinta HV marka la isticmaalayo habka flashover-ka si loo ogaado cilada impedance sare.
●Awood gubasho xoog leh, max.Awoodda gubashada waa 1000W, barta burburku waa lagu gubi karaa waqti gaaban, caabbinta dhibic jabinta waa la dhimay.
●Haddii si wadajir ah loola shaqeeyo GD-4133 Cable Fault Tester, waxaa jira laba siyaabood oo lagu helo:
a.garaaca garaaca hoose: Haddii kaliya la isticmaalayo GD-4133, wareegga furan iyo impedance hoose cilada dhulka ee fiilada waa la heli karaa, iyo dhererka fiilada waa la qiyaasi karaa, ama xawaaraha hirarka fiilada waa la ogaan karaa.
b.Tooshka sare ee koronta: Qaabka mowjadda korantada garaaca wadnaha ee cilada waxa lagu muunadeeyay iyada oo la saarayo faraqa xajka, kaas oo ogaan kara fogaanta cilladda.
●Samee dareenka soo noqnoqoshada go'an.Haddii si wadajir ah loola shaqeeyo GD-4132 Cable Fault Locator, waxaa jira hawlo soo socda:
a.Inta jeer ee maqalka: hel caqabad sare, khaladaad toos ah.
b.Si aad u tilmaamto dariiqa fiilada, aqoonso fiilada gaarka ah.
c.Si loo burburiyo macdan (dhimashada dhulka), iyadoo la adeegsanayo cabbiraadda magnetic- field si loo helo si sax ah.
●Waxa kale oo loo isticmaali karaa in DC HV ee imtixaanka adkaysiga.
●Korontada wax gelinta: AC 220V,50Hz
●Korontada wax soo saarka: DC 0-32kV (la hagaajin karo)
●Awoodda la qiimeeyay: 2kVA
●Max.tamarta: 2048J, 4uF
●Danab toosan oo DC ah: 32kV
●Xakamaynta tooska ah ee DC: 63mA
●Max.xawaaraha hadda jira: 500mA
●Habka soo daynta: DC HV, hal mar, wareeg
●Waqtiga wareegga wareegga: 3-6 ilbiriqsi
●Heerkulka deegaanka:0-40℃
●Qoyaanka: <75% RH
●Joog:<1000m
●Heerka dahaarka: A
●Cabirka: 430*540*410mm
●Miisaanka: qiyaastii 31kg.
GD-4132 Ciladaha Cable ee Goobta
Oo ay ku jiraan unugga ugu muhiimsan, acoustic iyo magnetic sensor, headphone ka-hortagga qaylada iyo dabaylaha.Way ku habboon tahay in lagu tijaabiyo dhammaan noocyada fiilada korantada oo leh kaari macdan ah.Shaqadeeda ugu weyn waa helitaanka barta dahaarka liidata, ogaanshaha wareegga iyo qoto dheer ee fiilada korontada.
●Acoustic Magnetic helida isku mar
●Awood xoog leh oo ka-hortagga faragelinta
●Iyada oo leh taleefoonka dhegaha ee buuqa.
●320*240 LCD soo bandhigayKu-dhismay awood weyn oo Li-batteri ah, oo leh dabaysha degdega ah.
●Acoustic iyo Magnetic signal waveform bandhigay, signal iyo qaylada waa ay fududahay in la kala saaro.
●Isticmaalka cursor si loo cabbiro dhawaaqa iyo daahitaanka birlabeedka, si sax ah u go'aami barta cilladda.Sida laga soo xigtay polarity bilowga ah ee mawjada magnetka, waxay heli kartaa oo ogaan kartaa dariiqa.
1. Helitaanka shaqada
a.Kooxda gudbinta calaamadaha Acoustic: inta jeer ee xarunta 400Hz, bandwidth 200Hz
b.Helitaanka isha: 80dB
c.Xaqiijinta goobta: 0.1m
2. Korontada a.Ku-dhismay Li-batteri, danab magaciisu yahay 7.4V, awoodda 3000mAH.b.Isticmaalka awoodda: 300mA, waqti shaqo oo joogto ah 9 saacadood.c.Dabaylaha: inputAC220V± 10%, 50Hz.Wax soo saarka magaca ah 8.4V, DC 1A d.Wakhtiga dallacaadda: 4saacadood
3. Cabirka: 270mm*150mm*210mm
4. Miisaanka: 1.5kg.
5. Isticmaal xaalad heerkulka -10 ℃ - 40 ℃, huurka 5-90% RH, sare <4500m
GD-4133 Ciladaha Cable-ka
GD-4133 Cable Fault Detectot waxaa loo isticmaalaa in lagu cabbiro masaafada u dhaxaysa ciladaha fiilada.Way fududahay in lagu shaqeeyo oo leh interface saaxiibtinimo.
Waxaa loo isticmaali karaa kaligiis habka garaaca garaaca hooseeya.Marka la eego qaabka hadda garaaca wadnaha, waxay u baahan tahay inay la shaqeyso GD-2131 koronto-dhaliyaha sare.Marka loo eego habka garaaca garaaca badan, lammaane GD-4133S waa in si wadajir ah loo wada shaqeeyaa.Ka dib meelaynta fogaanta, GD-4132 meeleeyaha khaladka waa in loo adeegsadaa tilmaamida khaladka.Alaabooyinkan waxaa lagu dari karaa qaab hawleedka sare iyo nidaamka tijaabada khaladka fiilada.
●7inch LCD screen, interface saaxiibtinimo.
●Habka meelaynta masaafo badan:
Habka garaaca garaaca hooseeya: waxay ku habboon tahay helitaanka cilladda iska caabbinta hooseeya, cillad gaaban oo gaaban, cillad furan oo furan.Waxa kale oo loo isticmaali karaa cabbiraadda dhererka fiilada, kala-goysyada dhexdhexaadka ah, kala-goysyada T, iyo joojinta fiilada.Habkan sidoo kale waxaa loo isticmaali karaa in lagu saxo xawaaraha hirarka.
Habka hadda jira ee garaaca: Waxay ku habboon tahay cabbiraadda fogaanta ee ciladda caabbinta sare, cilladda burburka.Isticmaalka lammaanaha hadda jira si aad u soo ururiso calaamadaha siliga dhulka, waxay ka dhigaysaa isticmaaluhu meel ka fog tamarta sare.Habkani waa mid ammaan ah oo la isku halayn karo.
garaaca garaaca badan: habka horumarsan ee lagu cabbiro fogaanta.Qaabka mowjadu waa sahlan tahay in la aqoonsado saxnadu waa sarraysaa.
●Muunad-qaadista 200MHz ee waqtiga-dhabta ah.Max.0.4m xallinta cabbirka.Waxay leedahay aag dhintay oo yar waxayna gaar u tahay fiilada gaaban iyo fiilada cilladda u dhow.
●Shaashada taabo oo taabo hawlgalka furaha
●Nuqulka PIP (sawirka kaydinta ku meel gaarka ah)
●Waxa jiri doona daaqad weyn iyo saddex daaqadood oo kaydinta ku meel gaadhka ah ayaa si wada jir ah u hubin doona saddexda mowjadood.
●Nidaamka qalliinka ee la dhisay
Maaraynta software ee gaarka ah ee cusboonaysiinta software-ka, kaydinta iyo soo celinta
●Shaqada miisaanka
Bar bilawga ah, 10 xiriiriye, hal xadhig oo cilad ah iyo hal dherer oo buuxa ayaa dejin kara.
Miisaanka iyo qaabka hirarka tijaabada wada
●Kaydinta waveform iyo xidhiidhka kombiyuutarka
Kaydinta gudaha ee qaababka hirarka
Iyada oo USB, si loo soo dejiyo ama loo soo geliyo xogta
Isgaadhsiinta kombiyuutarka
●Maamulka awoodda
Iftiinka dambe wuu daciifaa haddii aanu hawlgelin 2mins gudahooda oo dami 10mins haddii aanu hawlgelin.
Ku-dhismay baytariyada Lithium-ion ee Polymer
Waqtiga shaqadu waa ilaa 5 saacadood isticmaal kasta.
Kiis adag, si fudud loo qaadi karo.
Hababka meelaynta | Habka kicinta danab hoose Dhaqdhaqaaqa habka hadda jira Habka kicinta badan haddii la mid ah GD-4133S |
Max.Inta jeer ee muunada | 200MHz |
Kala duwanaanta faa'iidada | 0-70dB |
Danab yar oo firfircoon | 30V |
Max.xallinta | 0.4m |
Max.Helitaanka xadka | 100km |
Aagga dhintay | 2m |
Battery | Nickel-metal hydride baytariyada dib loo buuxin karo, waqti adkeysi ka badan 5 saacadood |
Isku xirka isgaarsiinta | USB |
Korontada | Gelida AC220V, 50Hz, hadda 2A, lacag 8 saacadood |
Dim | 274×218×81mm |
Miisaanka | 3.5kg |
Heerkulka shaqada | -10℃-40℃ |
Qoyaanka | 5-90% RH |
Sare u qaadis | <4500m |
GD-4133S Multiple Pulse Coupler
Waxa ay la shaqaynaysaa GD-4133 Cable Fault Detector, oo loo isticmaalo in lagu ogaado cillada korontadu sarayso, cilada toosan, dhulka impedance hoose iyo cilada wareegga furan ee fiilooyinka korantada.GD-4133S waxay siisay calaamadda isku-xidhka garaaca wadnaha ee GD-4133 oo ka soocday qalabka korantada sare.
●Isticmaalka tignoolajiyada ugu horumarsan ee isku dhafan ee garaaca wadnaha iyo dheelitirka garaaca wadnaha
●Ilaalinta badbaadada HV, wareegga cabbiraadda iyo awoodda kicinta tamarta sare ayaa koronto ahaan go'doonsan.
●Xadhkaha fudud, badbaado leh oo la isku halayn karo.
Tilmaamaha
●Korantada garaaca wadnaha: 300V (PP)
●Qulqulka kicinta la oggol yahay: <35kV
●Tamar kicinta la oggol yahay: <2000J
●Galinta awooda: 220VAC, 50Hz
●Cabirka: 560*230*220mm
●Miisaanka: 7kg.
GD-2134D Aqoonsiga Cable
GD-2134D Cable Identifier waxaa ka mid ah gudbiye iyo aqbale, waxaa loo isticmaali karaa in lagu helo raadadka iyo qoto dheer ee fiilooyinka dhulka hoostiisa ah iyo tuubooyinka macdan, sidoo kale si loo ogaado fiilada laga soo bilaabo farabadan fiilooyinka.
●Si toos ah u muuji meesha tuubada.
●Tilmaanta fallaadha bidix/midig ee Raadinta Waddada Cable-ka.
●Waqtiga dhabta ah cabbir jihada hadda taagan iyo beenta/sax ah ee soo noqnoqoshada qayb ahaan.
●Tilmaanta saxda ah/Beenta.Waxay tilmaamaysaa hore marka fiilada la ogaaday si sax ah loo raadiyo.Haddii kale, waxay tilmaamaysaa gadaal waxayna muujin doontaa "?".
●Si toos ah u cabbirka qoto dheer iyo hadda.
●Aqoonsiga fiilada: Aqoonsiga xajinta iyo aqoonsiga stethoscope.Aqoonsiga xajintu waxay si sax ah u cabbiri kartaa baaxadda hadda iyo jihada fiilada waxayna siin kartaa natiijo sax ah.Aqoonsiga Stethoscope waa hab dhaqameed marka aysan ku habboonayn isticmaalka aqoonsiga Clamp.Way fududahay in silig loogu xidho aqoonsiga Stethoscope.
●Isticmaalka rack(kaaliyaha ikhtiyaariga ah) si loo helo cilad-xumada ee dahaarka dhulka.Muhiim ma aha in la qabsado booska eber.Falaadhtu waxay tilmaantaa jihada ciladda.
●Tijaabinta buuxda ee muunad iyo habayn sax ah oo saraysa, oo leh qayb helid cidhiidhi ah iyo faragelin xoogan.Waxay si buuxda u xakamaysaa soo noqnoqoshada awoodda iyo faragelinta iswaafajinta ee fiilooyinka socda ee dhow.
●Ogaanshaha firfircoon iyo ogaanshaha dadban.
●Ku-dhismay baytariga awoodda weyn ee Lithium.Si otomaatig ah u damisa korantada marka uu ka hooseeyo korantada ama shaqayn la'aan muddo dheer.
Gudbiye
●Soo saarista (Saddex qaab): Soo saarista isku xirka tooska ah, Soo saarista Isku-xidhka Isku-xidhka (ikhtiyaarka), kicinta shucaaca.
●Soo noqnoqda (6 doorasho): 640Hz, 1280Hz, 10kHz, 33kHz, 83kHz, oo ay ku jiraan 640Hz iyo 1280Hz waa soo noqnoqoshada adag.Waxay xaqiijin kartaa shaqada tilmaanta Saxda ah/Beenta iyo aqoonsiga tuubada iyadoo la kaashanayo qaataha.
●Soo saarida calaamada cilladda si loo ogaado cilada dhulka tubada.
●Wax soo saarka tamarta: Max10W, 10 tallaabo oo la hagaajin karo.
●Korontada wax soo saarka ee xiriirka tooska ah: Max.150Vpp.
●Isbarbardhigga tooska ah iyo hawlaha culeyska xad dhaafka ah& ilaalinta wareegga-gaaban.
●Korontada: Bateriga Lithium-ka ee gudaha lagu shuban karo, 4pcs, model no.18650.magac ahaan 7.4V, 6.8Ah.
●Adag oo la qaadi karo.
qaataha
●Qaabka wax-soo-gelinta:-ku-dhex-dhisan helitaanka gariiradda, helidda xajinta(ikhtiyaarka), echometer(ikhtiyaar), Rack (ikhtiyaar).
●Laba xabbo oo soo noqnoqda ogaanshaha dadban: soo noqnoqda awoodda iyo soo noqnoqoshada raadiyaha (RF).Looma baahna in lagu xidho dhaliye soo noqnoqda maqalka.
●Inta jeer ee la helayo:
Inta jeer ee ogaanshaha firfircoon: 640Hz, 1280Hz, 10kHz, 33kHz, 83kHz
Inta jeer ee ogaanshaha dadban PF: 50/60Hz iyo 250/300Hz
Inta jeer ee ogaanshaha dadban RF: inta jeer ee xarunta waa 10kHz, 33kHz, 83kHz siday u kala horreeyaan.
●Habka ogaanshaha: habka ugu sarreeya, hab cidhiidhi ah, habka aan lahayn.
●320*240 pixel screen LCD.
●Ku-dhismay baytari lithium dib-u-jallaabi kara, 2pcs 18650 Li batari, magac ahaan.7.4V, 3.4Ah.
●Adag oo la qaadi karo.
Tilmaamo kale
●Cabbirka: Transformer 270*220*85mm, qaataha 700*270*120mm.
●Miisaanka: gudbiyaha 2.2kg, qaataha 2.2kg.
●Dameeraha: gelinta AC 100-240V, 50/60Hz, wax soo saarka DC 8.4V, 2A.
●Xaaladda shaqada: Heerkulka -10--40 ℃.Qoyaanka 5-90% RH, Dhererka <4500m.
GD-2135 Qalabka Daloolinta Cable
GD-2135B Cable Puncture Aaladda sidoo kale waa tilmaanta fiilada, si loo aqoonsado fiilooyinka fiilooyinka badan.
Waa qalab dalool oo ammaan ah oo aan lala xidhiidhin, oo leh meel fog iyo kontorool waqtiyeed.
Qalabkani waxa uu ka kooban yahay laba qaybood, qalabka ciddiyaha iyo qalabka xakamaynta.Waa batari ku shaqeeya, kaas oo ka soocaya qalabka dalool ee nidaamka korontada, si loo hubiyo badbaadada sahayda korontada.
●Waxay ku habboon tahay daloolista dhammaan noocyada fiilooyinka korantada, badbaado leh oo la isku halleyn karo.
●Laba qaab oo shaqo, oo ay ku jiraan fogaanta iyo wakhtiga.Laba badhan oo loo istcmaali doono in lagu galo qaabka shaqada, hubi badbaadada hawlwadeenka.
●Laba badhan oo fog (furaha C iyo D ayaa isku mar la riixay).Si loo hubiyo helitaan la isku halayn karo, anteenada gudbinta ee kontoroolka fog waa in gebi ahaanba la soo saaro.
●Isticmaalka qoriga labajibbaaran si aad u daloosho xaglo labanlaab ah.Hal qalliin oo tijaabo ah si loo dhammeeyo daloolo labanlaab ah.
●Iyada oo leh alaarmiga dhawaaqa iyo bandhig LCD.
●Naqshad dhowr ah oo ilaalin ah oo ay sameeyeen makaanikada iyo elektiroonigga.
●Gaar ahaan loogu talagalay daloolista fiilada, oo si toos ah loogu dhejiyay fiilada, oo lagu rakibay xagal kasta.
●Isticmaalka batari ku shaqeeya, ku haboon isticmaalka duurjoogta ah iyada oo aan lahayn koronto.Sidoo kale, waxay ka soocaysaa aaladda daloolinta nidaamka korontada, si loo hubiyo badbaadada.
●Masaafada fog ee fiilo la'aanta: ≤ 20M.
●Codsiga fiilada: dhammaan fiilooyinka korantada ≤ ¢125mm
●Awoodda shaqada: 6pcs 1.5V batari.
●Xaaladda shaqada: heerkulka -10--50 ℃, qoyaanRH<95%.
●Miisaanka: 15kg oo ay ku jiraan kiis aluminium ah.
●Cabirka: 48*45*16cm