GD-4138H Nidaamka Helitaanka Cilada Cable
GD-4138H Nidaamka Helitaanka Khaladka Cable Cable waa qalab muhiim ah si loo ilaaliyo dhammaan noocyada fiilooyinka.Waa qalab ku habboon oo raadsan kara, heli kara fiilooyinka dhulka hoostiisa, oo leh cabbirka fogaanta cilladda iyo jiilka HV.Maadaama ay tahay aalad la guuri karo, way ku habboon tahay in lagu qaado goobta.Haddii cod-yaqaanka si wadajir ah loo isticmaalo, waxay heli kartaa booska saxda ah ee barta cilladda fiilada.
Codsigu waa fiilada dhulka hoostiisa, fiilada hawada, fiilada korontada, fiilada maxalliga ah, fiilada isgaarsiinta iyo fiilada fiber-ka.
●Cilad sare oo toosh ah
●Diidashada impedance sare
●Dhulka iska caabinta sare/hoose
●Cilad gaaban oo gaaban
●Ciladda wareegga furan
●Xidhiidhka xun/goynta
●GD-4138H (qalabka isku-xidhka, farqiga Sphere, koronto-dhaliyaha HV ayaa gudaha ku jira)
●GD-4133 Tijaabada khaladka fiilada garaaca wadnaha ee badan
●GD-4132 Ciladaha Cable ee Goobta
●Hababka kala duwan ee kala duwan: Habka garaaca garaaca korantada hooseeya, habka garaaca wadnaha ee hadda jira, habka garaaca wadnaha oo badan: muunad hadda jirta, wax soo saarka DC.
●Noocyada calaamadaha: Habka milicsiga DC, shaybaarka hadda jira, shaybaarka tamarta, garaaca garaaca tamarta hoose.
●Si deg deg ah u hel oo tilmaan cilada caabbinta hoose, caabbinta sare iyo ciladaadka fiilooyinka korantada ee 220V~220KV ee kala duwan.
●Looma baahna in la fuliyofiilooyinka adag ee baaritaanka goobta.Dhammaan hababka tijaabada waxaa si toos ah loogu dareemaa dareeska danabka sare ee gudaha ee ay maamusho hadda daciifka ah.
●Isku-dhafan koronto-dhaliyaha-sare ee DC-xawaaraha badan leh, capacitor-xawaaraha badan ee korantada sare, unugga xasilinta arc iyo helitaanka calaamado kala duwan oo mid ah, fududahay in lagu shaqeeyo nidaamka goobta qaladka.
●Wax soo saarka heer-kala duwan oo koronto sare leh, dhammaan waxaa gacanta ku haya danab hoose oo gudaha ah oo daciif ah, ammaan ah oo la isku halayn karo.
●Qaab dhismeedka qalabku wuxuu qaataa kiis caag ah oo aad u sarreeya.Kiisku waa sanduuqa dibedda ee qalabka iyo sanduuqa wareejinta ee xirmada bixinta qalabka.Way ku habboon tahay in la wareejiyo, waana la rari karaa oo si toos ah loo wareejin karaa marka daboolka la xiro.
●Dheecaan ka soo daadasho la'aan ah ee Sphere: farqiga hawo-mareenka solenoid ee kantaroolka daciifka ah, muddada dheecaanku waa la hagaajin karaa 3 ilaa 12 ilbiriqsi, muffler-ga waxaa si gaar ah loogu talagalay inuu buuxiyo shuruudaha carrabka la'aanta fiilada ee bilowga.
●Qalabku wuxuu leeyahay wareegga dareeraha ee ku dhex jira.Kadib marka baaritaanka cilada la dhameeyo, korontada sare waa la damin karaa kaliya taabo batoonka meesha laga saarayo si aad si toos ah uga baxdo.
●Masaafada cabbiraadda martida loo yahay waxay bixin kartaa masaafo cabbiraysa xallinta ilaa 0.4m, aagga cabbiraadda indha la'aanta waa yar tahay, taas oo si gaar ah waxtar u leh cilladaha dhammaadka dhow iyo fiilooyinka gaaban.
●Dhammaan mashiinnada wax soo saarka ee qalabka ayaa lagu hagaajiyay dhinaca dambe si loogu fududeeyo fiilooyinka, iyo jaantusyada fiilooyinka hababka kala duwan ee qalabka ayaa lagu sawiray guddiga hawlgalka, kuwaas oo ay si fudud u isticmaali karaan dadka aan khibradda lahayn.
●Qeybta hoose ee qalabka waxaa lagu qalabeeyay 4 taayir oo xoog badan, kuwaas oo la riixi karo oo la isku dhejin karo si loo kaydiyo.
●Martigeliyaha kala duwani wuxuu isticmaalaa 7-inch LCD-shaashadda weyn oo leh xagal daawashada 160°, waxa ku jira muuqaalkuna waa qani oo dareen leh.
●Tiro badan oo mowjado ah ayaa lagu kaydin karaa martida loo yahay, xogta waveform waa la soo dejin karaa oo la dhoofin karaa iyadoo la isticmaalayo U disk.
●Martigeliyaha waxaa lagu xiri karaa kombuyuutar (desktop ama buug xusuus qor) si loo wada xiriiro khadka internetka.
●Marka martigeliyaha uusan wax qalliin ah ku sameynin 2 daqiiqo gudahood, iftiinka dambe ayaa daciifi doona;haddii aysan jirin qalliin 10 daqiiqo ah, si toos ah ayay u xirmi doontaa si loo yareeyo isticmaalka korontada;marka batteriga uu hooseeyo, qalabku sidoo kale si toos ah ayuu u dami doonaa si uu u ilaaliyo batteriga.
●Martigeliyaha waxa uu leeyahay batari ku dhex jira polymer-ka lithium-ion waxana uu ku qalabaysan yahay batari lithium u go'an si loo bixiyo hab lagu dallaco oo la isku halayn karo.
●Mashiinka oo dhan wuxuu qaataa naqshadaynta qaab dhismeedka sanduuqa wareejinta, kaas oo is haysta oo adag, gaar ahaan ku habboon isticmaalka goobta dhismaha.
Qaabka | GD-4138L | GD-4138M | GD-4138H |
Habka tijaabada | Habka milicsiga Arc, muunad hadda jirta, wax soo saarka DC | Habka milicsiga Arc, Habka milicsiga DC, muunad hadda jirta, wax soo saarka DC | |
Kala duwanaanshaha nooca calaamad muunada | Habka milicsiga garaaca wadnaha oo badan, muunad hadda jirta, garaaca garaaca wadnaha oo hooseeya | Habka milicsiga Arc, Habka milicsiga DC, muunad hadda jirta, wax soo saarka DC | |
Wax soo saarka DC HV | 0~16KV taban Wax soo saarka ugu badan ee hadda: 152mA | 0~32KV xun xun Wax soo saarka ugu badan ee hadda: 76mA | 0~8KV polarity taban Wax soo saarka ugu badan ee hadda: 304mA 0~16KV polarity xun wax soo saarka ugu badan ee hadda: 152mA 0~32KV polarity xun wax soo saarka ugu badan ee hadda: 76mA |
Awoodda Flashover | 0-16kV 8μF Tamarta wax soo saarka ugu badan: 1024J | 0-32kV 4μF Tamarta wax soo saarka ugu badan: 2048J | 0-8kV 32μF Tamarta wax soo saarka ugu badan: 1024J 0-16kV 8μF Tamarta wax soo saarka ugu badan: 1024J 0-32kV 4μF Tamarta wax soo saarka ugu badan: 2048J |
Si otomaatig ah u daadinta farqiga u dhexeeya sphere | Hawo-mareenka solenoid ee kontoroolka daciifka ah ee hadda jira, muddada dheecaanku waa la hagaajin karaa laga bilaabo 3 ilaa 12 ilbiriqsi, muffler-ga waxaa si gaar ah loogu talagalay inuu buuxiyo shuruudaha carrabka ee cilladda fiilada bilowga. | ||
Qaabka wax soo saarka | DC waxay u adkaysanaysaa danab, dareere keli ah, dareere xilliyeed | ||
DC u adkeyso danab | 16KV | 32KV | 32KV |
Voltage kicinta la oggol yahay | 16kV | 32kV | 32kV |
Tamar kicinta la ogolaan karo | <2048J | ||
Deegaanka shaqada | Heerkulka: 0 ~ 40 ℃ Qoyaanka qaraabada: <75%RH | ||
Korontada | AC220V, 50Hz | ||
Awoodda guud | 3kVA |
Waxaa loo isticmaalaa in lagu cabbiro fogaanta cilladda.Marka la eego qaabka garaaca wadnaha LV, waxaa la isticmaali karaa kaligiis.
7inch LCD screen, interface saaxiibtinimo.
Habka meelaynta masaafo badan:
Habka garaaca garaaca hooseeya: waxay ku habboon tahay helitaanka cilladda iska caabbinta hooseeya, cillad gaaban oo gaaban, cillad furan oo furan.Waxa kale oo loo isticmaali karaa cabbiraadda dhererka fiilada, kala-goysyada dhexdhexaadka ah, kala-goysyada T, iyo joojinta fiilada.Habkan sidoo kale waxaa loo isticmaali karaa in lagu saxo xawaaraha hirarka.
Habka hadda jira ee garaaca: Waxay ku habboon tahay cabbiraadda fogaanta ee ciladda caabbinta sare, cilladda burburka.Isticmaalka lammaanaha hadda jira si aad u soo ururiso calaamadaha siliga dhulka, waxay ka dhigaysaa isticmaaluhu meel ka fog tamarta sare.Habkani waa mid ammaan ah oo la isku halayn karo.
garaaca garaaca badan: habka horumarsan ee lagu cabbiro fogaanta.Qaabka mowjadu waa sahlan tahay in la aqoonsado saxnadu waa sarraysaa.
Muunad-qaadista 200MHz ee waqtiga-dhabta ah.Max.0.4m xallinta cabbirka.Waxay leedahay aag dhintay oo yar waxayna gaar u tahay fiilada gaaban iyo fiilada cilladda u dhow.
Shaashada taabo oo taabo hawlgalka furaha.Calaamadaha waa la jiidi karaa.
Nuqulka PIP (sawirka kaydinta ku meel gaarka ah)
Waxa jiri doona daaqad weyn iyo saddex daaqadood oo kaydinta ku meel gaadhka ah ayaa si wada jir ah u hubin doona saddexda mowjadood.
Nidaamka qalliinka ee ku dhex jira
Maaraynta software ee gaarka ah ee cusboonaysiinta software-ka, kaydinta iyo soo celinta
Shaqada miisaanka
Hal meel oo laga bilaabo, 10 xiriiriye, hal xadhig oo cilad ah iyo hal dherer oo buuxa ayaa dejin kara.
Muuji miisaanka iyo qaabka hirarka tijaabada isku mar
Kaydinta waveform iyo xidhiidhka kombiyuutarka
Kaydinta gudaha ee qaababka hirarka
Iyada oo USB, si loo soo dejiyo ama loo soo geliyo xogta
Isgaadhsiinta kombiyuutarka
Maamulka awoodda
Iftiinka dambe wuu daciifaa haddii aanu hawlgelin 2mins gudahooda oo dami 10mins haddii aanu hawlgelin.
Ku-dhismay baytariyada Lithium-ion ee Polymer
Waqtiga shaqadu waa ilaa 5 saacadood isticmaal kasta.
Kiis adag, si fudud loo qaadi karo.
Hababka meelaynta | Habka kicinta danab hoose Dhaqdhaqaaqa habka hadda jira Habka kicinta badan |
Max.Inta jeer ee muunada | 200MHz |
Kala duwanaanta faa'iidada | 0-70dB |
Danab yar oo firfircoon | 30V |
Max.xalinta | 0.4m |
Max.Helitaanka xadka | 100km |
Aagga dhintay | 2m |
Battery | Nickel-metal hydride baytariyada dib loo buuxin karo, waqti adkeysi ka badan 5 saacadood |
Isku xirka isgaarsiinta | USB |
Korontada | Gelida AC220V, 50Hz, 2A hadda, dallaca 8 saacadood |
Dim | 274×218×81mm |
Miisaanka | 3.5kg |
Heerkulka shaqada | -10℃-40℃ |
Qoyaanka | 5-90%RH |
Sare u qaadis | <4500m |
●Acoustic iyo magnetic signal waa la helay isku mar.Awood xoog leh oo ka-hortagga faragelinta.
●bandhig waveform
●Acoustic magnetic waveform bandhigay.
●Helitaanka barta qaladka iyo raadinta dariiqa.
●Taleefoonka dhegta lagu maqlo buuqa.
●320*240 LCD soo bandhigay, interface saaxiibtinimo.
●Ku-dhismay baytari Li, oo leh xajiyeyaasha degdega ah.
●Si otomaatig ah ayay u dami doontaa haddii aanu shaqaynayn 15mins ka dib ama batari yar.
●Cabbir yar, si fudud loo qaadi karo.
●Baaxadda calaamadaha Acoustic: inta jeer ee xarunta 400Hz, bandwidth 200Hz
●Helitaanka isha: 80db.
●Xaqiijinta goobta: 0.1m
●Korontada: Ku-dhismay baytari Li, danab magaciisu yahay 7.4V, 3000mAh, shaqo joogto ah 9saacadood.
●Dameeraha: Galka AC220V±10%, 50Hz, wax soo saarka magacaaban 8.4V, DC1A
●Waqtiga dallacaadda: <4 saacadood
●Cabirka: 270*150*210mm.
●Miisaanka: 1.5kg.
●Xaaladda isticmaalka: heerkulka -10--40 ℃, qoyaan 5-90% RH, sare <4500m.