GD-7018A Aqoonsiga Fiber Optical
GD-7018 taxanaha dhuumaha fiber indhaha ayaa si sax ah u heli kara oo cabbiri kara qoto dheer ee dhuumaha dhulka hoostiisa, fiilooyinka iyo fiilooyinka indhaha ee hoos yimaada xaaladda iyada oo aan la qodin, oo si sax ah u hel dhibcooyinka dhaawaca ee daahan dibadda ah ee dhuumaha dhulka hoostiisa iyo goobta dhibcooyinka qaladka fiilada dhulka hoostiisa.Qalabku waxa uu ku daraa tignoolajiyada ugu horumarsan sida filter band aadka u cidhiidhi ah, xidhiidhka wireless Bluetooth, meelaynta GPS, xogta tooska ah ee software falanqaynta xogta xirfadeed iyo jiilka tooska ah ee warbixinnada imtixaanka.Ogaanshaha iyo kormeerka noocyada kala duwan ee dhuumaha birta, maaraynta iyo dayactirka dhuumaha, qorshaynta iyo dhismaha dawladda hoose, kormeerka dhuumaha tamarta iyo waaxaha kale waa mid ka mid ah aaladaha lagama maarmaanka u ah qaybaha dayactirka dhuumaha.
(1) Shaqooyin badan
1. Shaqada gudbiyaha: Waxa ay leedahay saddex nooc oo codsi ah oo habka kicinta ah, habka tooska ah iyo habka isku dhejinta, oo ku habboon waqtiyo kala duwan.
2. Shaqada qaataha: Waxaa loo isticmaalaa in lagu cabbiro goobta, jihada, qoto dheeraanta aaska iyo hadda ee tuubooyinka iyo fiilooyinka dhulka hoostiisa.
3. Fallaadhaha meelaynta bidix iyo midig waxay tilmaamayaan meesha dhuumaha la beegsanayo, iyo goobta la dhigay waa mid degdeg ah oo sax ah;fallaadhaha hore iyo dambe iyo qiimaha dB waxay muujinayaan meesha iyo xajmiga barta dhaawaca ee lakabka anticorrosive.
4. Iyada oo shaqeynaysa iftiinka dambe, oo ku habboon samatabbixinta degdegga ah ee habeenkii.
5. Shaqada meelaynta juqraafiyeed ee GPS, khariidaynta dhuumaha tooska ah.
6. Software falanqaynta xogta xirfadeed, soo saarida tooska ah ee warbixinta imtixaanka.
7. Shaqooyinka gaarka ah ee qaataha 7018E: Waxaa loo isticmaalaa in lagu ogaado cilladaha (pipeline failure waxay loola jeedaa dhaawaca lakabka ka hortagga daxalka ee dibadda, cilladda fiilada waxaa loola jeedaa dhaawaca lakabka difaaca dibadda), iyo si loo ogaado dhaawaca dahaarka. ee dhuumaha dhulka hoostiisa mara.
8. Cabbirka hadda: cabbir hadda lagu dabaqo gudbiyaha tuubada tijaabada.
9. Multimeter function: waxa ay cabbiri kartaa danab soo saarka, danab line, line hadda, impedance iyo awoodda.Tijaabi sii wadida iyo tayada dahaadhka fiilada ka hor iyo ka dib raadinta khaladka fiilada.
10. Xakamaynta induction dibadda: ku habboon meesha aan calaamaduhu si toos ah ugu xidhi karin marka la ogaanayo fiilada.
(2) Saxnaanta meelaynta sare
1. Noocyo kala duwan oo cabbirro ah oo loogu talagalay meelaynta dhuumaha (qaabka dooxada, qaabka ugu sarreeya, qaabka ugu sarreeya, qaabka ugu sarreeya) ayaa si wadajir ah loo xaqiijin karaa si loo hubiyo saxnaanta meelaynta dhuumaha.
2. Habka ugu sarreeya: qaabka ugu sarreeya, qaabka ugu sarreeya ee ballaaran, qaabka fallaadha ugu sarreeya ayaa loo isticmaali karaa in lagu cabbiro isbeddelka qaybta jiifka ah ((HX)) ama jaan-gooyaha toosan (△HX), oo ku hel iyadoo loo eegayo booska qiimaha ugu sarreeya;
3. Habka ugu yar: Isticmaal habka hoose si aad u go'aamiso booska qiimaha ugu yar adiga oo cabbiraya isbeddelka qaybta toosan (HZ).
(3) Waxaa jira habab badan oo dhawaaqa
1. Hababka wax lagu ogaado ee kala duwan ayaa loo dooran karaa si sabab la'aan ah oo si wadajir ah loo xaqiijin karo.
2. Habka akhriska tooska ah oo leh gariiro siman oo laba geesood ah.
3. Habka gariiradda hal heerka 80%, habka 50%.
4. Habka 45 degree.
(4) Faragelin xooggan oo ka dhan ah
1. Halbeegyo badan oo indho-indhayn ah: Qaybaha jiifka ah (HX), qaybta toosan (HZ) iyo jaan-gooyaha siman (△HX) waa la cabbiri karaa.
2. Awoodda gudbinta sare: Awoodda wax-soo-saarka gudbiyaha waa ilaa 10W oo si joogto ah loo hagaajin karo.Waxaa loo dooran karaa si sabab la'aan ah iyadoo loo eegayo baahida.
3. Soo noqnoqoshada shaqada oo badan:
Inta jeer ee gudbinta: 128Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
Inta jeer ee soo-gaadhista: raadiyaha, 50Hz, 100Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
4. Marka loo eego sifooyinka dhuumaha bartilmaameedka ah (qalabka, qaab-dhismeedka, qoto dheer ee la aasay, dhererka, iwm.), dooro inta jeer ee shaqada ee ku habboon.
(5) Hawl fudud
1. Dareen leh: Bandhig garaafeed ayaa loo isticmaalaa si joogto ah iyo waqtiga dhabta ah loo soo bandhigo cabbirro kala duwan iyo xoogga calaamadaha inta lagu jiro habka ogaanshaha.
2. Si toos ah: Si toos ah ugu beddel qaabka anteenada laba-heer ah oo si toos ah u hagaajiso dareenka qaataha marka la cabbirayo qoto dheer, si loo gaaro calaamadda cabbirka ugu fiican, oo si toos ah ugu soo noqo habka shaqada ka hor ka dib marka la dhammeeyo.
(6) Waqti dheer oo shaqo oo joogto ah iyo kharash yar oo la isticmaalo
Gudbiyaha waxa lagu rakibay batari lithium ah oo awood badan, kaas oo dabooli kara baahida koronto ee hal maalin goobta lagu ogaanayo hal lacag, waxaana dib loo warshadayn karaa, taas oo aad u yaraynaysa kharashka lagu ogaanayo.
(7) Gudbiye --AC iyo DC laba-isticmaalka
Xaaladaha caadiga ah, haddii batteriga gudbiyaha uu buuxo, isticmaal baakad ku dhex jirta si aad u siiso koronto.Haddii inta lagu jiro isticmaalka, batteriga gudbiyaha uu yar yahay, laakiin hawsha ogaanshaha lama dhammaystirin, waxaad si toos ah ugu xiri kartaa adabtarada korantada ee gaarka ah, qalabka si caadi ah ayaa loo isticmaali karaa, adigoon sugin in qalabka si buuxda loo dallaco ka hor isticmaalka.
Qiyaasta Farsamada | Ataxane | Btaxane | Ctaxane | Dtaxane | Etaxane |
Helitaanka Inta jeer | 5 | 6 | 7 | 8 | 10 |
Soo noqnoqda | 512,1K,33K,83K | 512,1K,33K,83K | 512,1K,33K, 83K | 512,1K,33K,65K,83K | 512, 1K, 2K, 33K, 65K, 83K |
Soo noqnoqoshada dadban | 50Hz | 50Hz 100Hz | 50Hz 100Hz raadiyaha | 50Hz 100Hz raadiyaha | 50Hz 100Hz raadiyaha |
Shaandheeyaha Korontada | × | × | √ | √ | √ |
Inta jeer ee cilada | × | × | × | × | 2 |
Khalad helista | × | × | × | × | √ |
baytari lithium ion | √ | √ | √ | √ | √ |
Frame | × | × | × | × | √ |
Helitaanka Qoto dheer (m) | 6 | 6 | 6 | 6 | 6 |
Kaydinta xogta | × | × | × | √ | √ |