GD-4136H Nidaamka Helitaanka Cilad-xumada Cable
GD4136H Nidaamka Ciladda Cable waa qalab muhiim ah oo lagu ilaaliyo dhammaan noocyada fiilooyinka.Waxay isticmaashaa siyaabo kala duwan oo lagu ogaanayo si ay u tijaabiso cilladaha fiilooyinka, taas oo ku habboon heerarka kala duwan ee fiilooyinka korantada iyo fiilooyinka isgaarsiinta.
Nidaamku wuxuu ka kooban yahay cutubyo hoos ku qoran:
1.GD-2131H Matoor kicinta
2.GD-4132 Cable Cable Locator
3.GD-4133 Qaladka Cable-ka garaaca badan
4.GD-4133S Multi-pulse Coupler
5.Alaabo kale
GD-2131H Soo-saare kicinta
Waxaa loo isticmaalaa in lagu dhaliyo dareen-celinta HV marka la isticmaalayo habka flashover-ka si loo ogaado cilada impedance sare.
●Awood gubasho xoog leh, max.gubashadu waa 1000W, burburdhibic waxaa lagu gubi karaa waqti gaaban iyo caabbinta dhibic jabinta waa la dhimay.
●Haddii si wadajir ah loola shaqeeyo GD-4133 Cable Fault Tester, waxaa jira laba siyaabood oo lagu helo:
a.garaaca garaaca hoose: Haddii kaliya la isticmaalayo GD-4133, wareegga furan iyo impedance hoose cilada dhulka ee fiilada waxaa la heli karaa, iyo dhererka fiilada waa la qiyaasi karaa ama xawaaraha hirarka fiilada waa la ogaan karaa.
b.Tooshka sare ee koronta: Qaabka mowjadda korantada garaaca wadnaha ee cilada waxa lagu muunadeeyay iyada oo la saarayo faraqa xajka, kaas oo ogaan kara fogaanta cilladda.
●Samee dareenka soo noqnoqoshada go'an.Haddii si wadajir ah loola shaqeeyo GD-4132 Cable Fault Locator, waxaa jira hawlo soo socda:
a.Inta jeer ee maqalka: soo hel cidhiidhi sare, khaladaadka toosh.
b.Si aad u tilmaamto dariiqa fiilada, aqoonso fiilada gaarka ah.
c.Si loo burburiyo macdan (dhimashada dhulka), iyadoo la adeegsanayo cabbiraadda magnetic- field si loo helo si sax ah.
●Waxa kale oo loo isticmaali karaa in DC HV ee imtixaanka adkaysiga.
●Korontada wax gelinta: AC 220V, 50Hz
●Korontada wax soo saarka: DC 0-32kV (la hagaajin karo)
●Awoodda la qiimeeyay: 2kVA
●Tamarta ugu badan: 2048J, 4uF
●Danab toosan oo DC ah: 32kV
●Xakamaynta tooska ah ee DC: 63mA
●Ugu badnaan hadda: 500mA
●Habka soo daynta: DC HV, hal mar, wareeg
●Waqtiga wareegga wareegga: 3-6 ilbiriqsi
●Heerkulka deegaanka:0-40℃
●Qoyaanka: <75% RH
●Joog:<1000m
●Heerka dahaarka: A
●Cabirka: 430*540*410mm
●Miisaanka: ilaa 31kg.
Oo ay ku jiraan unugga ugu muhiimsan, acoustic iyo magnetic sensor, headphone ka-hortagga qaylada iyo dabaylaha.
Way ku habboon tahay in lagu tijaabiyo dhammaan noocyada fiilada korantada oo leh kaari macdan ah.
Shaqadeeda ugu weyn waa helitaanka barta dahaarka liidata, ogaanshaha wareegga iyo qoto dheer ee fiilada korontada.
●Acoustic Magnetic helida isku mar.
●Awood xoog leh oo ka-hortagga faragelinta.
●Iyada oo leh taleefoonka dhegaha ee buuqa.
●320*240 LCD soo bandhigay.
●Ku-dhismay awood weyn oo Li-batteri ah, oo leh dabaysha degdega ah.
●Acoustic iyo Magnetic signal waveform bandhigay, signal iyo qaylada waa ay fududahay in la kala saaro.
●Isticmaalka cursor si loo cabbiro dhawaaqa iyo daahitaanka birlabeedka, si sax ah u go'aami barta cilladda.
●Marka loo eego polarity-ka bilowga ah ee magnetic.waveform, waxa ay heli kartaa oo ay marin kartaa ogaanshaha.
1. Helitaanka shaqada
a.Kooxda gudbinta calaamadaha Acoustic: inta jeer ee xarunta 400Hz, bandwidth 200Hz
b.Helitaanka isha: 80dB
c.Xaqiijinta goobta: 0.1m
2.Awoodda
a.Ku-dhismay Li-batteri, danab magaciisu yahay 7.4V, awood 3000mAH.
b.Isticmaalka awoodda: 300mA, waqti shaqo oo joogto ah 9 saacadood.
c.Dabaylaha: gelinta AC220V± 10%, 50Hz.Wax soo saarka magaca ah 8.4V, DC 1A
d.Wakhtiga dallacaadda: 4saacadood
3. Cabirka: 270mm*150mm*210mm
4. Miisaanka: 1.5kg.
5. Isticmaal xaalad
Heerkulka -10 ℃ - 40 ℃, huurka 5-90% RH, sare <4500m
GD-4133 Qalabka Ciladda Cable-ka ayaa loo isticmaalaa in lagu cabbiro
fogaanta u dhaxaysa khaladaadka fiilooyinka.Way fududahay in
shaqeeyaan oo leh interface saaxiibtinimo.
Waxaa loo isticmaali karaa kaligiis habka garaaca garaaca hooseeya.U
Marka la eego qaabka hadda garaaca wadnaha, waxay u baahan tahay inay la shaqeyso GD-2131
dhaliye danab sare. Under habka garaaca garaaca badan, GD-4133S
lammaane waa in laga wada shaqeeyo.Ka dib meelaynta fogaanta, GD-4132 meeleeyaha khaladka waa in loo adeegsadaa tilmaamida khaladka.Alaabooyinkan ayaa lagu dari karaa
set oo ah waxqabadka sare iyo nidaamka tijaabada khaladka fiilada cusub.
●7inch LCD screen, interface saaxiibtinimo.
●Habka meelaynta masaafo badan:
Habka garaaca garaaca hooseeya: waxay ku habboon tahay helitaanka cilladda iska caabbinta hooseeya, cillad gaaban oo gaaban, cillad furan oo furan.Waxa kale oo loo isticmaali karaa cabbiraadda dhererka fiilada, kala-goysyada dhexdhexaadka ah, kala-goysyada T, iyo joojinta fiilada.Habkan sidoo kale waxaa loo isticmaali karaa in lagu saxo xawaaraha hirarka.
Habka hadda jira ee garaaca: Waxay ku habboon tahay cabbiraadda fogaanta ee ciladda caabbinta sare, cilladda burburka.Isticmaalka lammaanaha hadda jira si aad u soo ururiso calaamadaha siliga dhulka, waxay ka dhigaysaa isticmaaluhu meel ka fog tamarta sare.Habkani waa mid ammaan ah oo la isku halayn karo.
garaaca garaaca badan: habka horumarsan ee lagu cabbiro fogaanta.Qaabka mowjadu waa sahlan tahay in la aqoonsado saxnadu waa sarraysaa.
●Muunad-qaadista 200MHz ee waqtiga-dhabta ah.Max.0.4m xallinta cabbirka.Waxay leedahay aag dhintay oo yar waxayna gaar u tahay fiilada gaaban iyo fiilada cilladda u dhow.
●Shaashada taabo oo taabo hawlgalka furaha
●Nuqulka PIP (sawir.kaydinta ku meel gaadhka ah)
Waxa jiri doona daaqad weyn iyo saddex daaqadood oo kaydinta ku meel gaadhka ah ayaa si wada jir ah u hubin doona saddexda mowjadood.
●Nidaamka qalliinka ee la dhisay
Maaraynta software ee gaarka ah ee cusboonaysiinta software-ka, kaydinta iyo soo celinta
●Shaqada miisaanka
Bar bilawga ah, 10 xiriiriye, hal xadhig oo cilad ah iyo hal dherer oo buuxa ayaa dejin kara.
Miisaanka iyo qaabka hirarka tijaabada wada
●Kaydinta waveform iyo xidhiidhka kombiyuutarka
Kaydinta gudaha ee qaababka hirarka
Iyada oo USB, si loo soo dejiyo ama loo soo geliyo xogta
Isgaadhsiinta kombiyuutarka
●Maamulka awoodda
Iftiinka dambe wuu daciifaa haddii aanu hawlgelin 2mins gudahooda oo dami 10mins haddii aanu hawlgelin.
Ku-dhismay baytariyada Lithium-ion ee Polymer
Waqtiga shaqadu waa ilaa 5 saacadood isticmaal kasta.
Kiis adag, si fudud loo qaadi karo.
Hababka meelaynta | Habka kicinta danab hoose Dhaqdhaqaaqa habka hadda jira Habka kicinta badan haddii la mid ah GD-4133S |
Max.Inta jeer ee muunada | 200MHz |
Kala duwanaanta faa'iidada | 0-70dB |
Danab yar oo firfircoon | 30V |
Max.xalinta | 0.4m |
Max.Helitaanka xadka | 100km |
Aagga dhintay | 2m |
Battery | Nickel-metal hydride baytariyada dib loo buuxin karo, waqti adkeysi ka badan 5 saacadood |
Isku xirka isgaarsiinta | USB |
Korontada | Gelida AC220V, 50Hz, hadda 2A, lacag 8 saacadood |
Dim | 274×218×81mm |
Miisaanka | 3.5kg |
Heerkulka shaqada | -10℃-40℃ |
Qoyaanka | 5-90%RH |
Sare u qaadis | <4500m |
Waxay la shaqaynaysaa GD-4133 Cable Fault Detector,loo isticmaalo in lagu ogaado cilada soo daadata impedance sare, cilada biqilka,dhulka impedance hoose iyo cilada wareegga furan ee fiilooyinka korontada.
GD-4133S waxay keentay calaamadda isku xidhka garaaca wadnaha ee GD-4133 iyoka go'doomiso qalabka tamarta sare leh.
●Isticmaalka tignoolajiyada ugu horumarsan ee isku dheelitirnaanta garaaca wadnaha iyo garaaca wadnaha.Qaabka mawjadaha ka muuqda ayaa aad u fudud in la aqoonsado.
●Ilaalinta badbaadada HV, wareegga cabbiraadda iyo awoodda kicinta tamarta sare ayaa koronto ahaan go'doonsan.
●Xadhkaha fudud, badbaado leh oo la isku halayn karo.
●Korantada garaaca wadnaha: 300V (PP)
●Qulqulka kicinta la oggol yahay: <35kV
●Tamar kicinta la oggol yahay: <2000J
●Awood gelinta: 220V AC, 50Hz
●Cabirka: 560*230*220mm
●Miisaanka: 7kg.