GDZRC-100U Transformer DC tijaabiyaha iska caabinta dabaysha
Transformer DC iska caabinta dabaysha waa shayga tijaabada ah ee looga baahan yahay tijaabada wershada, rakibaadda, dib-u-habaynta, beddelka furaha tuubada, tijaabada wareejinta iyo tijaabada ka hortagga ee waaxda korantada.Waxay hubin kartaa tayada alxanka ee kala-goysyada dabaysha iyo haddii ay jirto wareeg gaaban oo u dhexeeya dabaylaha.Waxay ogaan kartaa in xidhiidhka boos kasta oo ka mid ah qalabka korontada ku shaqeeyaa uu fiican yahay, iyo haddii booska dhabta ah ee taabashadu uu la mid yahay booska la tilmaamay, haddii uu jiro jabka xadhigga rasaasta, haddii uu jiro xadhig jaban. silig badan oo xarig ah iyo dabeylo.
GDZRC-100U Transformer DC Resistance Tester waxaa loo qaabeeyey si loo daboolo baahiyaha cabbiraadda degdegga ah ee iska caabinta dabaysha ee Transformer DC.Qalabku wuxuu qaataa tignoolajiyada cusub ee sahayda korantada, oo leh cabbir yar, miisaan fudud, wax soo saar weyn oo hadda ah, ku celcelin wanaagsan, awood xoog leh oo ka hortagga faragelinta iyo shaqada ilaalinta qumman.Mashiinka oo dhan waxaa gacanta ku haya xawaare sare oo hal-kumbuyuutar ah oo chip-kaliya ah, otomaatig sarreeya, oo leh dareere otomaatig ah iyo shaqada alaarmiga.Qalabku wuxuu leeyahay saxsanaan sare iyo hawlgal sahlan, kaas oo xaqiijin kara cabbirka degdegga ah ee iska caabbinta dabaylaha ee Transformer DC.
●Mashiinka oo dhan waxaa gacanta ku haya microcomputer-hal-chip-xawaaraha sare leh oo leh automation sare, fududahay in la shaqeeyo.
●Qalabku wuxuu qaataa tignoolajiyada cusub ee sahayda tamarta, oo leh gears badan oo hadda jira iyo cabbir baaxad leh, kaas oo ku habboon cabbiraadda iska caabbinta DC ee beddelayaasha waaweyn iyo kuwa dhexdhexaadka ah.
●Iyada oo leh shaqo ilaalin buuxda.Waxay ka ilaalin kartaa aaladda saamaynta thr ee counter EMF, oo la isku halayn karo.
●Qaylo-dhaanta soo daynta dhawaqa, soo saarista calaamad cad, hawlgal khaldan waa la dhimay.
●Jawaab degdeg ahBeddelka tuubada korka saaran si toos ah ayaa loogu rogi karaa heerka cabbiraadda, qalabkuna wuxuu si toos ah u cusbooneysiin karaa xogta.
●Iyada oo tignoolajiyada maaraynta awooda caqliga leh, qalabku had iyo jeer wuxuu ku shaqeeyaa xaalada awooda ugu yar, badbaadinta tamarta wax ku oolka ah, yaraynta kulaylka.
●65K midabka dhabta ah, 320*240 LCD.
●Qalabku waxa uu la socdaa saacad kalandarka iyo kaydinta korontada, kaas oo kaydin kara 1000 qaybood oo xogta tijaabada ah oo dib loo eegi karo wakhti kasta.
●Qalabku waxa uu ku qalabaysan yahay RS232 iyo USB interface, kaas oo qalabku kula xidhiidhi karo kombayutarada oo uu ku kaydin karo xogta ku jirta saxanka USB
●Iyada oo micro printer uu saaran yahay guddiga.
Wax soo saarka hadda | 100A, 50A, 20A, 10A, 5A |
Min.xallinta | 0.1μΩ |
Qiyaasta kala duwan | At 100A: 50μΩ ~ 100mΩ; at 50A: 100μΩ ~ 200mΩ; at 20A: 200μΩ ~ 800mΩ; at 10A: 500μΩ ~ 2Ω; at 5A: 1mΩ~4Ω |
Saxnaanta | ± (0.2%+2 nambar) |
Heerkulka shaqada | 0℃~40℃ |
Qoyaanka qaraabada | <90% RH (ma jiraan wax buufin ah) |
Cabbirka | 440*245*395mm |
Miisaanka | qalabka: 19.5kg;kiis dheeri ah: 7.5kg |
Tijaabiye | 1 set |
Xadhiga korantada | 1 pc |
Tijaabada khadka | 1 set |
Warqad daabac | 1 duub |
Fuse | 2 pcs |
Fiilada dhulka | 1 pc |
RS232 khadka isgaarsiinta | 1 pc |
Shayga tijaabi | 1 pc |
Tilmaamaha isticmaalaha | 1 koobi |
Kaarka dammaanadda | 1 koobi |
Warbixinta tijaabada warshadda | 1 koobi |