GDKC-15 Taxanaha Wareegga Wareegga
Xakamaynta wareegga korantada ee sarreeya waa mid ka mid ah qalabka ugu muhiimsan ee xakamaynta nidaamka korantada.Taxanaha GDKC-15 waxaa loo isticmaalaa in lagu tijaabiyo sifooyinka firfircoon ee jabiyaha korantada sare.Way fududahay in la shaqeeyo, iyada oo saxnaanta sare leh.
GDKC-15A | GDKC-15B | GDKC-15C | GDKC-15D | GDKC-15E | GDKC-15F | GDKC-15G | GDKC-15H | |
Xiriirka birta | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
Iska caabin xidhidh | 6 | 6 | 6 | 6 | 6 | 6 | 6 | |
Xiriirka garaafka | 3 | 3 | 3 | 3 | 6 | |||
Dhulka laba-dhammaadka ah | 3 | 3 | 3 | 6 | ||||
Iska caabin firfircoon (hor-u-gelinta iska caabin ah) | 1 | 1 | 3 | 3 | 3 | 3 | 6 | |
iska caabin taagan | 1 | 1 | 3 | 3 | 3 | 3 | 6 | |
Iska caabinta dhulka | 3 | 6 |
●Waxay ku habboon tahay tijaabada farsamada ee dhammaan noocyada furayaasha SF6, qalabka isku dhafka ah ee GIS, furayaasha vacuum iyo furayaasha saliidda.
●Awood xoog leh oo ka-hortagga faragelinta.Waxa si fudud loo tijaabin karaa oo si sax ah loogu cabbiri karaa substation 500KV ah.
●Accelerometer (ikhtiyaar), dareeraha toosan, dareeraha wareega, fududahay in la rakibo oo fudud.
●Dhammaan xogta wareejinta tijaabada sifada farsamaysan iyo khariidadda waveform ee u dhiganta waxa la helayaa ka dib marka shidmada la dhaqaajiyo hal mar.
●Kaydi xogta imtixaanka goobta iyo saacada wakhtiga dhabta ah ee ku dhex jirta, taas oo ku haboon kaydinta iyo kaydinta taariikhda iyo wakhtiga imtixaanka.
●Iyada oo leh shaashad 10.1 inch LCD ah, soo bandhig dhammaan xogta iyo khariidadda, oo leh iftiinka asalka, hagaajinta isbarbardhigga LCD iyo awoodda deminta xusuusta.
●Hawlgalka menu saaxiibtinimo, fududahay in la isticmaalo.Daabacaha ku dhex jira si aad dhakhso ugu daabacdo dhammaan natiijooyinka xogta
●Ku qalabaysan software maamulka falanqaynta xogta, kaas oo lagu shaqayn karo onlayn PC, oo wata faylka qaabka WORD.Natiijooyinka imtixaanka waxaa loo soo saari karaa dhammaan noocyada daabacadaha daabacaadda warbixinnada imtixaanka si tijaabada goobta looga dhigo kombuyuutar.
●Furan oo dhow doorashada xawaaraha iyo shaqada isticmaale-qeexay oo loo dejiyay si waafaqsan baahida, oo ku habboon cabbirka xawaaraha nooc kasta oo shil ah.
●Waqtiga:
12 xiriir oo waqti furan (xiran).
In wejiga wada shaqaynta
Isku-dubarid-waji-ilaa-weji
●Dib u xidhaya:
CO, OC, waqtiga COC,
Waqtiga ugu horeeya ee furan, wakhtiga ugu horeeya ee dhow, wakhtiga labaad ee dhow, wakhti dhow, wakhti dhintay, wakhti xaadir ah ma jiro.
●Soo boodaya:
Xir wakhtiga boodboodka, wakhtiyada, habsocodka iyo qaabka hirarka xidhiidh kasta.
Furitaanka baaxadda dib u soo celinta ee xiriir kasta.
Xawaaraha: xawaaraha xidhiidhka ee furitaanka iyo xidhidhiyaha kaliya, xawaaraha ugu badan, qalooca sifada wakhtiga safarka.
Socdaalka: wadarta safarka, masaafada furan, safarka dhaafka, safarka xad dhaafka ah, baaxadda dib u soo celinta.
Hadda: furan/xiri hadda, jaantuska mowjadda hadda jira ee gariiradda furan/dhaw.
Korantada shaqaynaysa: ku dhex dhisan DC0 ~ 300V/20A dhijitaal ah, isha awoodeed ee la hagaajin karo ee jabiyaha, si toos ah u dhamaystirta tijaabada falcelinta LV ee jabiyaha wareegga iyo cabbirka qiimaha korantada waxqabadka
Iska caabbinta xidhitaanka: wakhtiga shubka ka hor, qaab-dhismeedka hore ee hirarka iyo qiimaha iska caabinta caabiyaha xidhitaanka ee 6xiriirada.(ikhtiyaar)
Xidhiidhka garaafka: wakhtiga furan, xidhitaanka iyo mowjada firfircoon ee xidhiidhka garaafiga ee Siemens oo leh xidhiidho 3 ama 6 ah.(ikhtiyaar)
Dejinta laba-dhammaadka ah: Hoos-u-dhigista 3 ama 6-way laba-dekedood, waxay si sax ah u cabbiri kartaa furitaanka iyo wakhtiga xidhitaanka.(ikhtiyaar)
Iska caabbinta joogtada ah: 1*100A cabbirka caabbinta xidhiidhka.
Iska caabbinta firfircooni (hor-u-gelinta iska caabbinta): 1*100A beddelka mowjadaha caabbinta firfircoon inta lagu jiro tallaabada wareegga wareegga.
●Deegaanka Isticmaalka
Awood-gelinta: 220V± 10%, 50Hz±10%, Cadaadiska Hawada: 86-106kpa
Heerkulka: -10-40℃ Qoyaanka: ≤80% RH
●Waxqabadka Badbaadada
Iska caabinta dahaarka>2MΩ
Awoodda Dielectric: Shell waxay u adkeysan kartaa koronta soo noqnoqda 1.5kV 1 daqiiqo iyada oo aan lahayn wax toosan iyo foorar.
●Halbeegyada aasaasiga ah
Waqtiga: Range 20000.0ms, xallinta 0.01ms, qalad 0.5%
Iska caabin xidhidh: kala duwanaansho 10kΩ, min.xallinta 1Ω, qalad 0.5% (ikhtiyaar)
Xidhiidhka garaafka: inta u dhaxaysa 200ms, min.xallinta 0.1ms, qalad 0.5% (ikhtiyaar)
Dhulka laba-dhamaadka ah: inta u dhaxaysa 200ms, min.xallinta 0.1ms, qalad 0.5% (ikhtiyaar)
Iska caabin taagan: kala duwanaanshiyaha 1uΩ~10mΩ, min.xallinta 0.01μΩ, qalad 0.5%
Iska caabin firfircoon: kala duwanaansho 10mΩ, min.xallinta 1μΩ, qalad 0.5%
Tijaabi hadda: DC 50A, 100A(3 wejiga la qiyaasay isku mar)
Xawaaraha: Xallinta 20.00m/s 0.01m/s qalad 0.5%
Safarka:
Noocyada | Range | Qaraarka | Khalad |
Faakuum jabiye | 50.0mm | 0.1mm |
0.5% |
Wareegtada SF6 | 300.0mm |
1mm | |
Saliidwareegga wareegga | 600.0mm |
Hadda: kala duwan 20.00A, xallinta 0.01A
Awoodda soo-saarka: DC 0-300V dhijitaalka ah oo la hagaajin karo/20A (shaqo degdeg ah), xallinta 1V.
Cabirka: qiyaastii 360mm (L)* 280mm (W)* 300mm (H)
Miisaanka: qiyaastii 10kg
Ugu weynunit oo leh kiniin 10.1-inch ah | 1 pc |
Kiis dheeri ah | 1 pc |
Ku dalacaha kiniinka | 1 pc |
Adapter-ka caadiga ah ee Ameerika | 2 pcs |
Rotari dareemaha xawaaraha | 1 pc |
Dareemaha xawaaraha tooska ah50mm | 1 pc |
Xawaaraha fiilada isku xirka signalka5-silig gaashaanka core) | 1 pc |
Furitaanka iyo xidhitaanka fiilada xakamaynta(3-fiilada galaha xudunta u ah) | 1 pc |
Kiciyeyaasha dibaddaogaadafiilo (cas/madow, 2-core) | 1 pc |
Fiilada dhulka | 1 pc |
Xariirka fiilada tijaabada(4-fiilada galaha xudunta u ah) | 1pc |
Cfiilo fidsan tijaabo toos ah (5M, jaale, cagaar iyo casaan midkiiba hal gabal, 3pcs madow) | 6kumbiyuutarada |
Fiilo gaaban (0.5m madow,2m madow) | 2 pcs |
Xadhiga korantada | 1 pc |
Isku-dhafka caalamiga ah iyo saldhigga magnetka | 1 dhigay |
Qalabka rakibaadda gaarka ah ee go'an | 1 set |
Tijaabi clips iyo tuman | 18 pcs |
Cfiilada tijaabada caabbinta ee tagta(5M) | 1 pc |
Warqad daabac | 2 duub |
fiilada USB | 1 pc |
Tilmaamaha isticmaalaha | 1 pc |
Warbixinta tijaabada warshadda | 1 pc |