GDPD-414H Qayb ka mid ah Soo saarista Gacanta ee Gacanta
●Chassis injineernimada ABS ee la qaadi karo.
●2 ama 4-madax-bannaan ee kanaalka helitaanka xog isku xidhan.
●8.1inch 1280*800 IPS taabashada shaashadda.
●Isticmaalka midabada casaanka, jaalaha ah, iyo buluugga si loo muujiyo darnaanta dheecaanka qayb ahaan.
●Celcelis ahaan wakhtiga dhib la'aanta ah waa in ka badan 50000 saacadood.
●Miisaanka cutubka ugu muhiimsan waa in ka yar 0.8kg.
●Falanqaynta softiweerka ku salaysan nidaamka ARM-ku-xidhan.Soo bandhig software ku salaysan nidaamka windows.
PD signal iibiyaha | |
Inta jeer ee shaqada CPU | 800MHz |
Nidaamka hawlgalka | Nidaamka hawlgalka ee Linx |
Dekadda shabkada silig | LAN network dekedda |
Dekadda shabakadda wireless-ka | Wifi wireless ku dhex jira |
Xusuusta socodsiinta nidaamka | 512M |
Xusuusta kaydinta nidaamka | 256M |
Inta jeer ee helitaanka xogta | 80MHz |
Kanaalka ogaanshaha Ultrasonic | |
Qiyaasta kala duwan | 0-60mV |
Kala duwanaanshaha ogaanshaha soo noqnoqda | 20-200kHz |
Kanaalka ogaanshaha UHF | |
Inta jeer ee la ogaado | 300 ~ 1500MHz |
Qiyaasta kala duwan | -80-10dBm |
Khalad | ±1dBm |
Qaraarka | 1dBm |
Kanaalka ogaanshaha HFCT | |
Kala duwanaanshaha soo noqnoqda | 0.5 ~ 100MHz |
Khalad | ±1dB |
Range firfircoon | 60dB |
Qiyaasta kala duwan | 0-100mV |
Saxnaanta | 1dB |
Kanaalka ogaanshaha TEV | |
Kala duwanaanshaha soo noqnoqda | 3 ~ 100MHz |
Khalad | ±1dB/mV |
Dareenka | 0.01mV |
Qiyaasta kala duwan | 0-60dB/mV |
Qaraarka | 1dBm/mV |
Battery | |
Batari ku dhex jira | Batteriga Lithium, 12V, 2000mAh |
Waqti isticmaal | qiyaastii 6 saacadood |
Waqtiga dallacaadda | Qiyaastii 2 saacadood |
Ilaalinta baytariga | Korantada xad dhaafka ah iyo ilaalinta hadda ka badan |
Ku dallaca batteriga | |
danab la qiimeeyay | 12.6V |
Dallacaadda wax soo saarka hadda | 2A |
Heerkulka shaqada | -20 ℃-60 ℃ |
Qoyaanka shaqaynaysa | <80% |
Terminalka bandhigga gacanta lagu hayo (darajada warshadaha) | |
processor | Intel Quad Core Atom Z3735F |
GPU | Sawirka Intel HD (Gen7) |
Fiiri | 32GB |
RAM | 2GB |
Nidaamka hawlgalka | Windows10 |
Bandhig | 8.1 inch 1280×800 IPS screen |
Isku xirka shabakada | Wifi iyo Bluetooth |
Battery | 3.7V 8500mAH polymer lithium ion batari |
Cabbirka | |
Cabbirka helitaanka PD | 240mm*165mm*55mm |
Helitaanka PD miisaanka martida loo yahay | 0.65kg |
Muuji xajmiga terminalka kiniinka | 395mm*295mm*105mm |
Muuji miisaanka dhamaadka kiniinka | 0.85kg |
Cabbirka sanduuqa guud | 570mm*360mm*240mm |
Deegaanka shaqada | |
Heerkulka shaqada | -20 ℃ ~ 50 ℃ |
Qoyaanka deegaanka | 0 ~ 90% RH |
heerka IP | 54 |
Fariintaada noo soo dir:
Halkan ku qor fariintaada oo noo soo dir