GDJF-2008 Falanqeeyaha Sii daynta Qaybaha ah
GDJF-2008 Detector qayb ka mid ah ayaa cabbiraya dareeraha qayb ka mid ah alaabada sida transformers, inductors, furayaasha HV, xirayaasha zinc monoxide iyo fiilooyinka korantada.Waxa kale oo ay samayn kartaa tijaabooyinka nooca iyo waxay la socon kartaa hawlgalka daaha.
Noocani waxa uu leeyahay faa'iidooyinka dareenka sare, baaxad balaadhan oo awood ah, oo si fiican u qalabaysan ogaanshaha impedance unug gelin iyo kala duwanaansho badan oo band band (9 in all).Ka dib marka si sax ah loo dejiyo, qadarka qulqulka qulqulka si toos ah ayaa loo akhriyi karaa.Mitirrada tilmaamaya iyo kuwa dhijitaalka ah ayaa la tusay isku mar.
Qalabkan ayaa si weyn looga dabaqaa xarumaha korontada, soosaarayaasha, iyo xarumaha.
●Heerkulka deegaanka: 0-40℃±2℃.
●Qoyaanka qaraabada: ≤80%
●Korontada: 220V± 10%, 50HZ.
●Ma jiro gariir xoog leh iyo shoog farsamo.
●Qalabka waa in lagu meeleeyaa deegaanka oo aan lahayn boodh iyo daxal, hawo wanaagsan.Waa in aan lagu faragalin korantada xooggan.
●Shuruudaha carrada: caabbinta carrada 1Ω
●Qiyaasta awoodda in lagu tijaabiyo 6PF-250μF.
●Dareenka tijaabada (oo lagu muujiyey Shaxda.1).
Cutubka galitaankaMaya | Awoodda hagaajinta | Unug | Dareenka (pC)(wareeg aan sinnayn) |
1 | 6-25-100 | pF | 0.02 |
2 | 25-100-400 | pF | 0.04 |
3 | 100-400-1500 | pF | 0.06 |
4 | 400-1500-6000 | pF | 0.1 |
5 | 1500-6000-25000 | pF | 0.2 |
6 | 0.006-0.025-0.1 | mF | 0.3 |
7 | 0.025-0.1-0.4 | mF | 0.5 |
8 | 0.1-0.4-1.5 | mF | 1 |
9 | 0.4-1.5-6.0 | mF | 1.5 |
10 | 1.5-6.0-25 | mF | 2.5 |
11 | 6.0-25-60 | mF | 5 |
12 | 25-60-250 | mF | 10 |
7R | iska caabin |
| 0.5 |
●Qalabka cod-weyneeye
Terminalka hoose: 10KHZ, 20KHZ, 40KHZ (ikhtiyaar)
Terminalka sare: 80 KHZ, 200 KHZ, 300 KHZ (ikhtiyaar)
● Hagaajinta helitaanka Amplifier
Xakamaynta adag - waxaa jira 6 gears oo loogu talagalay hagaajinta qallafsan, faa'iidada qalab kasta waa 20 ± 1db
Xakamaynta wanaagsan ≥ 20 db
● Time daaqadaha
Ballaca daaqada, la hagaajin karo 15o—150o
Meesha daaqada, 0o-170o la hagaajin karo
Laba daaqadood ayaa la wada furi karaa isku mar ama si gooni gooni ah.
● Mitirka dareeraha
Muujinta dhijitaalka ah
Muujinta PD: LED 3½ nambar
0-100.0 xadka khaladka <± 3% (cabir buuxa)
● Saldhigga waqtiga Ellipse
Soo noqnoqoshada: 50Hz iyo inta jeer ee aan sabab lahayn
Midabka muujinta Elliptic waa jaale
Wareegga Elliptic: qalab kasta waa 30 °, 180 ° wareeg ayaa la samayn karaa.
Muujin: ellipse - xariiq toosan
Wakhtiga soo noqnoqoshada sare ee saldhiga galitaanka elliptical in ka yar 220 V, awoodda qaadashada <1 VA
● Waveform quful
Quful loo baahan yahay qaab mawjada wakhti kasta si loo fududeeyo fiirsashada iyo falanqaynta
● Tijaabinta mitirka Voltage
Qiyaasta: 100KV (waa la kordhin karaa)
Muuji 31/2 mitir danab dhijitaal ah
Saxsanaanta: ka wanaagsan ± 2% (cabir buuxa)
● Gudaha, ka baxsan shaqada calaamada eber
●Cabirka: 450×450×190 mm
●Miisaanka: qiyaastii 16kg