GDJF-2007 Falanqeeyaha Qayb Dijital ah ee Dijital ah
GDJF-2007 Digital Discharge Analyzer waxaa si weyn loogu isticmaalaa in lagu ogaado qayb ka mid ah dareeraha qalabka korantada sare sida Transformers power, transformer tool, HV circuit breaker, GIS, Zinc oxide surge arrester, cable koronto.Waxa kale oo ay samayn kartaa tijaabooyinka nooca iyo waxay la socon kartaa hawlgalka daaha.
Waxaa ka mid ah unugga ugu muhiimsan, software PD, transformer-ka hadda, unugga gelinta, koronto-dhaliye garaaca wadnaha, adabtarada gelinta, cod-weyneeye anteeno iyo fiilada isku xirka iwm.
●Bandhig LCD 12inch ah, oo leh nashqad la qaadan karo, qalafsan oo waara, fududahay in la isticmaalo.
●Awood xoog leh oo ka-hortagga faragelinta, sax ah.Isticmaalka tignoolajiyada shaandhaynta dhijitaalka ah, faragelinta goobta si wax ku ool ah ayaa loo baabi'in karaa, cabirka dheecaanka qayb ahaana waxaa lagu xaqiijin karaa jawi faragelin xoog leh.
●Helitaanka xogta channel-ka badanHal shaashad ayaa soo bandhigi karta 2channels ama 4channel waveform.
●Shaqada software ee xoogga badan.Qiyaasta PD, falanqaynta, PD waqtiyada dheecaanka soo noqnoqda ee cabbiraadda N, falanqaynta iyo faragelinta ka-hortagga go'an, faragelinta firfircoonida.Doorashada xorta ah ee ellipse, xariiq toosan iyo qaabka bandhiga sinusoidal.Cabbir oo ku fiiri garaaca garaaca garaaca daaqada, iyo tijaabi danabka iyo hadda, dheecaanka qayb ahaan isku mar ayaa la qiyaasi karaa.Dhammaan xogta tijaabada ee 2channels waa la keydin karaa waqtigeeda.Qaabka hirarka tijaabada waa la keydin karaa, dib loo soo bandhigi karaa oo la falanqeyn karaa.Kala duwanaanshaha faa'iidada ee kanaal kasta waa la hagaajin karaa oo si fiican loo hagaajin karaa.Farsamada furitaanka daaqada dhijitaalka ah, si looga fogaado saameynta faragelinta cabbirka.Furitaanka wejiga daaqada, hal daaqad iyo labajibbaaran ayaa la dooran karaa.Daaqada si xor ah ayaa loo furi karaa gudaha 360degree.
●Si waafaqsan heerka IEC60270.
●Qiyaasta awoodda: 6pF-250μF
●Dareenka: 0.1pc
●Kanaalka cabbiraadda: 2 ama 4pcs kanaal madaxbannaan
●Saxnaanta muunadda: 12Bit
●Heerka muunadda: ugu badnaan100MHz halkii channel
●Cabbirka cabbirka: 0.1pc-10000nc.
●Kala duwanaanshaha firfircoon:>80db.
●Cabbirka inta jeer ee soo noqnoqda: 10kHz-1MHz at 3db.
●Inta jeer ee awoodda tijaabada: 50-400Hz.
●Shaandheynta la barnaamiji karo
Soo noqnoqoshada hooseeya: 10K, 20K, 40K, 80K;
Soo noqnoqda sare: 100K, 200K, 300K, 1000K.
●Heerkulka deegaanka: -15℃--50℃
●Qoyaanka qaraabada: ≤95% (20℃)
●Joog: ≤3000m.
●Awoodda saamaynta: 5000V deked kasta oo wax gelinta ah iyo korantada (positive, negative iyo AC)
●Galinta awoodda: AC220V± 10%, 45-65Hz, awood <500W.
●Miisaanka: qiyaastii 15kg.
●Cabirka: 58*36*32CM