GDPD-414 Deteer Qayb Qayb ah oo la qaadan karo
Ugu weyn
unug
Dareemaha UHF,
nooc wareegsan,ku haboon GIS
Dareemaha UHF, nooca leydi, ku haboon fiilada korontada, transformer, switchgear
HFCT, ku haboon fiilada korontada, transformer
Dareemaha TEV,
ku habboon qalabka beddelka
Dareemka Ultrasonic, oo ku habboon beddelayaasha, qalabka beddelka
Sawirada kore kaliya marka hore tixraac.
GDPD-414 la qaadan karo (GDPD-414H gacanta) Qayb ka mid ah soo saarista Detector wuxuu qaataa nidaamka tijaabada awooda caqliga degdega ah ee caqliga leh (Lambarka jilicsan 1010215, lambarka diiwaangelinta ganacsiga 14684781 (14684481)).Waxay si dabacsan u habeyn kartaa dareemayaasha kala duwan iyadoo loo eegayo alaabada kala duwan ee la tijaabinayo.TEV, ultrasonic iyo HFCT waxay ku habboon yihiin soo saarista qayb ka mid ah soo saarista qalabka beddelka ee korantada sare iyo golaha shabakada giraanta;Ultrasonic iyo UHF waxay ku habboon yihiin in la ogaado GIS;Ultrasonic iyo HFCT waxay ku habboon yihiin tijaabinta fiilada korontada.Nidaamka ogaanshaha khabiirka ee ku dhex jira wuxuu baari karaa xogta tijaabada wuxuuna xukumi karaa tamarta dheecaanka iyo qaybaha suurtagalka ah.Waxaa si weyn loogu isticmaalaa tamarta korontada iyo tareenada.
Dareemaha Ultrasonic iyo TEV (2-in-1)
●Qaado guddiga muunaynta DSP/FPGA-xawaaraha sarreeya, 4-channel xogta la wadaago
●Nidaamka Software: Software falanqaynta ku salaysan nidaamka gundhig ARM
●6/8/16 kanaalka waa la habeyn karaa
●8.1 inch tablet ama Thinkpad notebook sida ikhtiyaari ah
●6/8/16 kanaalka waxaa loo habayn karaa iyadoo loo eegayo baahida macaamiisha ee kala duwan.
●Waxay soo bandhigi karaan khariidadaha PRPS iyo PRPD, jaantusyada ellipse, khariidadaha heerka dheecaanka, khariidadaha QT, khariidadaha NT, khariidadaha PRPD isku-darka, khariidadaha fai-QN ee channel kasta.
● Noocyada calaamadaynta saddexda midab ee casaanka, jaalaha iyo buluuga waxay muujinayaan darnaanta dheecaanka qayb ahaan.
Macmiilku wuxuu dooran karaa dareemayaasha iyadoo loo eegayo walxaha kala duwan ee la tijaabiyey:
Dareemayaasha | TEV/AE/HFCT | AE/UHF | AE/HFCT |
Walxaha la tijaabiyay | HV Swichgear and Ring network cabinet |
GIS |
Cable |
PD signal iibiyaha | |
Inta jeer ee shaqada CPU | 1.2GHz / 800 MHz |
Nidaamka hawlgalka | Nidaamka hawlgalka ee Linx |
Dekadda shabkada silig | LAN network dekedda |
Dekadda shabakadda wireless-ka | Ku-dhismay WiFi wireless-ka (ikhtiyaar) |
Xusuusta socodsiinta nidaamka | 1G / 512M |
Xusuusta kaydinta nidaamka | 512M / 256M |
Inta jeer ee helitaanka xogta | 250MHz/80MHz |
Kanaalka ogaanshaha Ultrasonic | |
Qiyaasta kala duwan | 0-60mV |
Kala duwanaanshaha ogaanshaha soo noqnoqda | 20-200kHz |
Kanaalka ogaanshaha UHF | |
Inta jeer ee la ogaado | 300 ~ 1800MHz / 300 ~ 1500MHz |
Qiyaasta kala duwan | -80-10dBm |
Khalad | ±1dBm |
Qaraarka | 1dBm |
Kanaalka ogaanshaha HFCT | |
Kala duwanaanshaha soo noqnoqda | 0.5 ~ 100MHz |
Khalad | ±1dB |
Range firfircoon | 60dB |
Qiyaasta kala duwan | 0-100mV |
Saxnaanta | 1dB |
Kanaalka ogaanshaha TEV | |
Kala duwanaanshaha soo noqnoqda | 3 ~ 100MHz |
Khalad | ±1dB/mV |
Dareenka | 0.01mV |
Qiyaasta kala duwan | 0-60dB/mV |
Qaraarka | 1dBm/mV |
Battery | |
Batari ku dhex jira | Bateriga Lithium, 12V, 4400mAh / baytari lithium, 12V, 2000mAh |
Waqti isticmaal | qiyaastii 8 saacadood / ku dhawaad 6 saacadood |
Waqtiga dallacaadda | Qiyaastii 2 saacadood |
Ilaalinta baytariga | Korantada xad dhaafka ah iyo ilaalinta hadda ka badan |
Ku dallaca batteriga | |
danab la qiimeeyay | 12.6V |
Dallacaadda wax soo saarka hadda | 2A |
Heerkulka shaqada | -20 ℃-60 ℃ |
Qoyaanka shaqaynaysa | <80% |
GDPD-414H Gacmaha bandhiga terminaalka (darajada warshadaha) | |
processor | Intel Quad Core Atom Z3735F |
GPU | Sawirka Intel HD (Gen7) |
Fiiri | 32GB |
RAM | 2GB |
Nidaamka hawlgalka | Windows10 |
Bandhig | 8.1 inch 1280×800 IPS screen |
Isku xirka shabakada | Wifi iyo Bluetooth |
Battery | 3.7V 8500mAH polymer lithium ion batari |
Thinkpad Laptop ama PC Tablet | |
Cabbirka | |
Cabbirka kiiska dheeraadka ah / cabbirka helitaanka PD | 395mm*295mm*105mm/240mm*165mm*55mm |
PD miisaanka martida | 3kg / 0.65kg |
Cabbirka kiis tuubada PD / Muuji cabbirka terminalka kiniinka | 570mm*360mm*240mm/395mm*295mm*105mm |
Muuji miisaanka dhamaadka kiniinka | 0.85kg |
Cabbirka sanduuqa guud | 570mm*360mm*240mm |
Deegaanka shaqada | |
Heerkulka shaqada | -20 ℃ ~ 50 ℃ |
Qoyaanka deegaanka | 0 ~ 90% RH |
heerka IP | 54 |
GDPD-414H Qayb ka mid ah Soo saarista Gacanta ee Gacanta