GDWG-IV SF6 Gaaska Daadanaya (Taxane IR)
GDWG-IV SF6 Gas Leak Detector waa nooca dhuuban ee infrared (teknoolajiyada NDIR).Waa muujinta OLED midabka iyo waqtiga-dhabta ah waxay muujinaysaa fiirsashada SF6.Waxay si degdeg ah u ogaataa jabiyaha SF6, barta GIS ee daadinta iyo heerka daadinta sannadlaha ah si tayo iyo tiro ahaanba ah.Waa qalab wanaagsan oo ku habboon waaxda korontada, rakibidda iyo hagaajinta, machadka tijaabada korontada.
●Qalabka Bedelka Korantada Sare
●Rotor vane helicopter ah
●Nidaamka gudbinta gaaska
●Si loo ogaado dabdemiska
●Cilmi-baarista hufnaanta hawo-qaadista ee Dhismayaasha
●Si loo ogaado khatarta
●Shucaac ma laha.
●Looma baahna in la beddelo cadaadiska sare ee gaaska argon saafi ah si joogto ah.
●Looma baahna in loo dhawaado gaaska cadaadiska sarreeya.
●Looma baahna in la beddelo dareemayaasha si joogto ah, kharash-ool ah.
●Waxqabadka xasilloon, kharashka dayactirka oo hooseeya.Looma baahna in la sameeyo cabbir toosan sannad kasta.
●Wax saamayn ah kuma laha qoyaanka iyo wasakhowga deegaanka.
●Dareen sare, ilaa 0.01ppmv.
●Marka daadinta halista ah ama fiirsashada gaasta SF6 ay gaadho 100%, ma wasakhayso ama dhaawacmi mayso.
●Bandhig OLED.
●Ku-dhismay baytari lithium.
●Qeylo dhaan isticmaale-ku qeexan oo leh dhawaaq iyo iftiin.
●Dareen sare iyo xasilooni wanaagsan.
●Xawaaraha cabbirka degdega ah, wakhtigu waa ilaa 3s.
●Heerkulka iyo magdhowga cadaadiska.
●Kaliya jawaabta gaaska SF6, maaha gaaska kale.
●Cabbir yar, fududahay in la qaado, ku habboon shaqada goobta.
●Iyada oo leh xargaha gaaska ee aan sibidhka lahayn, aad u raaxo badan in lagu qaado.
●Kaydinta xogta ilaa 8000 oo kooxood.
●Aluminium khafiif ah oo leh qolof gaashaan oo buuxa.
●Xirmada dibedda waxay isticmaashaa balaastiig injineernimada, oo leh biyuhu-celiyaan, aan boodh lahayn.
●Mabda'a cabbiraadda: Dareemaha infrared aan kala firdhin (NDIR)
●Qiyaasta kala duwan: 0-5000ppm SF6
●Saxnimada: ± 2% FS (0-1000ppm)
●Khaladka ku soo noqnoqda: ≤± 1%
●Dareenka: 0.01ppmv
●Waqtiga jawaabta: ≤3s
●Waqtiga soo kabashada: ≤5s
●Xasilooni: ≤±20ppm, in ka badan 1000saacadood
●Bedelka eber: ≤±1% (FS/sanad)
●Cilad toosan: ≤±1%
●Heerkulka kaydinta: -20~+60℃
●Heerkulka shaqada: -20~+50℃
●Habka muunadda: Ku-dhismay bamka diaphragm elektromagnetic, nooca boos-ku-galka tooska ah, socodka ilaa 1L/daqiiqo.
●Korantada shaqaynaysa: 220VAC±10%,50Hz Ama Li-batteri-ku-dhisan
●Cabirka: 140×235×83mm
●Miisaanka: qiyaastii 1.5kg
Tijaabada CT/PT | 1 gabal |
Tijaabi hogaanka | 1set |
Fiilada dhulka | 1 gabal |
Xadhiga korantada | 1 gabal |
2A fiyuus | 2pcs |
Tilmaamaha isticmaalaha | 1 koobi |
Warbixinta tijaabada warshadda | 1 koobi |