GDWS-311RC SF6 Qalabka Dheebka Gaaska
GDWS-311RC waa aalad ku habboon in lagu tijaabiyo barta sayaxa ee gaaska SF6.Qaybta xudunta u ah waa dareemayaasha taxanaha ah ee DRYCAP oo ay soo saartay shirkadda Finland Vaisala.Iyada oo leh chips hardware-ka xirfadlayaasha ah iyo algorithms-yada software ee STMicroelectronics, waxaan soo saarnay jiil cusub oo ah qalabka tijaabada qoyaanka gaaska.
●Kormeerka qoyaanka ee qalabka korantada gaaska SF6 ee awooda korantada
●Tijaabada tayada gaasta SF6 gaaska
●Soo saarista gaasta nadiifka ah ee sare
●Warshadaha Semiconductors sahayda gaasta engegan
●Isticmaalka cilmi baarista iyo horumarinta
●La socodka qolka nadiifka ah/guriga qalalan
●Goobta daaweynta kulaylka birta iyo shaybaarka ogaanshaha qoyaanka gaaska warshadaha, sida hawada, CO2, N2, H2, O2, SF6, He, Ar iyo gaasaska kale ee aan shaqayn.
●Ka wanaagsan ±2℃ saxnaanta cabbirka.
●Dhammaan dariiqyada gaasku waa naqshadaynta walxaha polymer, waxay hubisaa inaysan jirin ifafaale ka laadlaadda gidaarka biyaha waxayna dammaanad qaadaysaa xawaaraha tijaabada.
●Jidhka nidaaminaya birta aan saliidda lahayn ayaa loo isticmaalaa si loo hubiyo saxnaanta qiimaha la cabbiray.
●Algorithms-yada horumarsan ee software waxay hagaajiyaan saxnaanta tijaabada dareemayaasha.
●Xalka qaabeynta chassis-ka la isku daray, isticmaalayaashu waxay si fudud isugu dari karaan agabka iyo agabka la xidhiidha.Xirmada guud waa la qaadaa, taas oo ka dhigaysa isticmaaluhu waayo-aragnimo nasasho badan.
●Tijaabada bilaw, looma baahna in la sii kululeeyo oo la gariiriyo.
●Beddelka heerkulka iyo hagaajinta xogta cadaadiska.
●Tignoolajiyada xisaabinta ee wareersan.
●Awood sare oo lithium batari ah, garwaaqso sahayda korantada ee AC iyo DC.Looma baahna korantada AC ee goobta.Korontada lithium-ka ayaa sii shaqaynaysa in ka badan 8 saacadood iyada oo aan loo baahnayn koronto dibadeed.
●Naqshadeynta wareegga faragelinta ka-hortagga-electromagnetic si loo hubiyo isku halaynta alaabta.
●Shaqada dib u warshadaynta gaaska, deegaanka-u-saaxiibtinimo.
●Xogta tijaabadu waa mid deggan waxayna bixin kartaa labadaba qiyamka dhibcaha sayaxa caadiga ah iyo qiyamka barta sayaxa ee 20 ℃.
●Aagga socodka tijaabada ugu fiican wuxuu muujinayaa in isticmaaluhu uu hagaajin karo socodka gaaska si dareen leh oo degdeg ah.Yaree wakhtiga imtixaanka.
●Meesha hawadu soo gasho waxa loo qaabeeyey isku xidh yar oo isku xidha, dariiqa hawada lagu tijaabinayaa ma daadan doono marka dariiqa hawadu go'do.
●Habka cabbirka: Mabda'a cabbiraadda adkaysiga iyo awoodda
●Baaxadda cabbirka: barta sayaxa -80℃--+20℃(taageerada ppmv)
●Saxnimada: ± 2℃
(marka heerkulka barta sayaxa uu ka hooseeyo 0 ℃, wax soo saarka dareemayaasha waa barta dhaxan)
●Waqtiga jawaabta: 63% [90%]
+20→-20℃ Td 5s[45s]
-20→-60℃ Td 10s[240s]
●Xallinta: 0.01℃
●Ku-celcelinta: ± 0.5 ℃
●Cutubka muujinta: ℃, ppm, ℃P20(qiimaha loo beddelay 20℃)
●Qulqulka gaaska: 400-600ml/min
●Muujinta socodka: 0-1000mL mitir socodka dhijitaalka ah
●Tusaalaha cadaadiska gaaska: ≤1MPa
●Korontada: 220VAC± 10%, 50Hz, isticmaalka AC/DC, shaqaynta joogtada ahi kama yarayn 8 saacadood.
●Isticmaal heerkulka deegaanka: -20--+60 ℃
●Qoyaanka deegaanka: 90% RH
●Saamaynta qiimaha cabbirka: Wax saamayn ah kuma laha cadaadiska iyo socodka
●Cabirka: 395*295*155mm
●Miisaanka: qiyaastii 2kg
Unugga ugu muhiimsan | 1 gabal |
Adapter | 1 dhigay |
Dhuumaha Teflon (oo ay ku jiraan waalka hagaajinta socodka iyo xiriiriyaha degdega ah) | 1 dhigay |
Dhuumaha dabada | 1 dhigay |
Qaybaha tafaariiqda | 1 dhigay |
Dameeraha | 1 gabal |
Isticmaale's Hagaha | 1 nuqul |
Warbixinta Imtixaanka | 1 nuqul |