GD6100C Transformer Insulation Saliida Tan Delta Tijaabadaha/Tijaabada Dielectric Saliida

GD6100C Transformer Insulation Saliida Tan Delta Tijaabadaha/Tijaabada Dielectric Saliida

Sharaxaad Kooban:

GD6100C Tijaabada Khasaarida Saliida Tooska ah ee Tooska ah, waxa loo isticmaalaa cabbiraadda is-diridda dielectric factor iyo caabbinta DC ee saliidda dahaadhka iyo dareerayaasha kale ee dahaadhka.


Faahfaahinta Alaabta

Tags Product

Warbixin guud

GD6100C Tijaabada Khasaarida Saliida Tooska ah ee Tooska ah, waxa loo isticmaalaa cabbiraadda is-diridda dielectric factor iyo caabbinta DC ee saliidda dahaadhka iyo dareerayaasha kale ee dahaadhka.Qalabku wuxuu dhexgalaa unugyada saliidda tijaabada, xakamaynta heerkulka, dareeraha heerkulka, buundada tijaabada lumista dielectric, awoodda tijaabada AC, capacitor caadiga ah, mitirka caabbinta sare, ilaha tamarta sare ee DC iyo qaybaha kale ee waaweyn.

Astaamaha

Unugga imtixaanku wuxuu qaataa qaab-dhismeedka saddexda-electrode sida waafaqsan heerka qaranka GB/T5654-2007, oo leh kala dheereynta korantada 2mm, taas oo meesha ka saari karta saameynta awoodda khaldan iyo daadinta natiijooyinka baaritaanka luminta dielectric.Qalabku wuxuu ku qalabaysan yahay dareeraha dareeraha saliidda ee solenoid, waxaanan faarujin karnaa unugga tijaabada anagoon ka saarin oo ku raacinnaa saliidda tijaabada.
Qalabku wuxuu qaataa kuleylinta soo noqnoqoshada soo noqnoqda dhexdhexaadka ah, algorithmaadka xakamaynta heerkulka PID.Habka kuleyliyuhu wuxuu leeyahay faa'iidooyinka xiriir la'aanta u dhaxaysa unugga tijaabada iyo kuleyliyaha jirka, kuleylinta isku midka ah, xawaaraha degdega ah, kontoroolka ku habboon, iyo si adag u xakameynaya heerkulka gudaha qaladka heerkulka hore.
Capacitor heerka gudaha waa SF6 gaas ka buuxo saddex-electrode capacitance, iyo lumitaanka dielectric capacitor iyo awoodda korantada ma saameeyaa heerkulka deegaanka, qoyaan iwm, si sax ah qalabka waa la hubin karaa xitaa ka dib isticmaalka dheer.
Tijaabada korantada AC waxay isticmaashaa beddelka AC-DC-AC, taas oo si wax ku ool ah uga hortagta isbedbedelka tamarta guud iyo soo noqnoqda inay saamayso saxnaanta cabbirka lumista dielectric.Xitaa koronto-dhaliye, qalabku si sax ah ayuu u shaqayn karaa.
Shaqada ilaalinta saxda ah. Marka uu jiro koronto ka badan, hadda ama koronto gaaban oo gaaban, qalabyadu waxay si dhakhso ah u jari karaan cadaadiska waxayna soo saaraan fariin digniin ah.Marka heerkulka dareemaha uu xumaado ama uusan ku xirneyn, qalabku wuxuu sidoo kale soo saari doonaa fariin digniin ah.
Waxa jira soo-gaadhis heerkul xaddidaya foornada kuleyliyaha soo noqnoqda ee inta jeer ee dhexdhexaadka ah.Marka heerkulku ka sarreeyo 120 digrii, qalabku wuxuu xoreeyaa relay-ga wuxuuna joojiyaa kuleyliyaha.
Meelaynta cabbirka tijaabada ku habboon. Heerkulka dejinta xadka 0 ~ 125 darajo, heerka dejinta korantada AC 500 ~ 2200V, dejinta korantada DC 0 ~ 500V.
Isticmaalka muraayad weyn oo LCD ah, oo leh iftiin dambe iyo muuqaal cad.Interface saaxiibtinimo, si fudud u raac isla markiiba menu-ka Shiinaha, geli amarka, qalabka si toos ah ayaa loo tijaabin karaa.Oo si toos ah u kaydi oo daabac natiijooyinka imtixaanka.
Saacadda-waqtiga-dhabta ah ee la dhisay, taariikhda iyo wakhtiga imtixaanka waa la keydin karaa, la soo bandhigi karaa oo la daabaci karaa natiijooyinka imtixaanka.
Shaqooyinka habaynta unugyada qalalan ee la nadiifiyey.Cabbirka awoodda unugga qallalan iyo isirka lumitaanka dielectric waxay go'aamin kartaa nadiifinteeda iyo xaaladaha isku-ururinta.Xogta isku-habaynta si toos ah ayaa loo kaydiyaa si ay u fududayso xisaabinta ogolaanshaha qaraabada iyo iska caabinta DC.

Tilmaamaha

sahayda korantada

AC 220V± 10%

Inta jeer ee awoodda

50Hz/60Hz ±1%

Qiyaasta kala duwan

Awoodda: 5pF ~ 200pF
Ogolaanshaha Qaraabada: 1.000 ~ 30.000
Khasaaraha Dielectric: 0.00001 ~ 100
Cadaadiska DC: 2.5MΩm ~ 20TΩm

Cabbiraadda saxnaanta

Awoodda: ± (1% akhriska+0.5pF)
Ogolaanshaha Qaraabada: ± 1% akhrinta
Qodobka kala daadsanaanta tamarta: ± (1% akhrinta+0.0001)
Cadaadiska DC: ± 10% akhrinta

Qaraarka

Awoodda: 0.01pF
Awoodda qaraabada: 0.001
Cunsurka dielectric dissipation factor: 0.00001

Kala duwanaanshaha heerkulka la qiyaasay

0 ~ 125 darajo

Khaladka cabbiraadda heerkulka

± 0.5 darajo

AC Test Voltage (RMS)

500 ~ 2200V Si joogto ah loo hagaajin karo, inta jeer ee 50Hz

Tijaabi Voltage DC

0 ~ 500V si joogto ah loo hagaajin karo

Isticmaalka tamarta

100W

Heerkulka deegaanka

0 ~ 40 darajo

Qoyaanka qaraabada (RH)

<75%

Cabirka

500×360×420

Wadarta miisaanka

22kg

 

Sawirada Alaabta

GD6100C Transformer Insulation Saliida Tan Delta Tijaabaha Saliida Dielectric Tester6
GD6100C Transformer Insulation Saliida Tan Delta Tijaabiyaha Saliida Dielectric Tester5
GD6100C Transformer Insulation Saliida Tan Delta Tijaabiyaha Saliida Dielectric Tester4
GD6100C Transformer Insulation Saliida Tan Delta Tijaabaha Saliida Dielectric Tester7

Macluumaadka Shirkadda

GD6100C Transformer Insulation Saliida Tan Delta Tijaabiyaha Saliida Dielectric Tester8
GD6100C Transformer Insulation Saliida Tan Delta Tijaabiyaha Saliida Dielectric Tester9
GD6100C Transformer Insulation Saliida Tan Delta Tijaabiyaha Saliida Dielectric Tester10
GD6100C Transformer Insulation Saliida Tan Delta Tijaabaha Saliida Dielectric Tester11

  • Hore:
  • Xiga:

  • Fariintaada noo soo dir:

    Halkan ku qor fariintaada oo noo soo dir

    Fariintaada noo soo dir:

    Halkan ku qor fariintaada oo noo soo dir