GDYZ-301A Zinc Oxide Qalabaynta Tijaabada Qabta
Waa qalabka gaarka ah ee tijaabinta waxqabadka korantada ee zinc oxide.Qalabku waxa uu si sax ah oo sugan u cabbiri karaa xidhxidhaha iska caabinta hadda iyo cabbiraha ka-hortagga ficilka marka qalabku socdo.Waxa kale oo ay hubin kartaa ammeter-ka kormeeraha.
●8inch midabka LCD taabashada shaashadda, daabacaadda kuleylka xawaaraha sare.
●Xogta cabbirka ee siliga iyo wirelessku waa isku mid.
●Muunad bilaa fiilo ah, oo leh masaafo dheer.
A. Fiilada: isticmaalka gudaha, ama goobta uu ku dhow yahay golaha xadhkaha muunada PT ee leh xidhaha hillaaca.
B. Wireless: isticmaalka bannaanka, ama goobta halka golaha fiilooyinka muunada ee PT uu ka fog yahay xiraha hillaaca la tijaabiyay, masaafada wirelessku waa ilaa 1000M.
●Saddex waji isku mar ayaa la qiyaasi karaa.Joogtada iska caabinta ee 3channels ayaa la qiyaasi karaa isla waqti isku mid ah, Dhanka kale, waxaa jira laba hab oo ka-hortagga faragelinta: 1) faragelin ma jirto: xagasha interphase lama xisaabin karo oo si toos ah looma sixi karo habkan;2) Faragelinta: xagasha faragelinta interphase waa la xisaabin karaa oo la sixi karaa.Isku xirka hal mar oo kaliya si loo dhammeeyo cabirka wajiga ABC
●Ku-dhismay awoodda sare ee Li-batteri, oo ku habboon meel aan koronto lahayn.
Use shuruud | -20 ℃ - 50 ℃ | RH<80% |
Ckorontadu ku xirto | AC 220V± 10% | |
Kala duwanaanshaha soo-gelinta ee danab tixraaca PT | 0-300V | |
Icaabbinta nput ee kanaalka danab | ≥150kΩ(wfiyuuska ith) | |
Cabbiraadda saxnaanta danab tixraaca PT | ±(2% akhrinta+0.5V) | |
Mfududaynta kala duwanaanta gelinta hadda | 0-10mA | |
Mhubinta saxnaanta aasaasiga ah ee hadda jirta | ± (2% akhrinta+5μA) | |
Mhubinta saxnaanta harmonic hadda | ±(5% akhrinta+10μA) | |
Input iska caabinta kanaalka hadda jira | ≤1Ω | |
Awaqtiyada kormeerka | 0~99times | |
8/20μS hadda | ≥50Ap | |
Ckala duwanaanshiyaha mitirka hadda jira | 0-10mA | |
Csaxnaanta alibration ee mitirka hadda jira | ±(2% akhrinta+5μA) | |
Mxallinta fududaynta | Voltaage | 0.001V |
Csoo noqnoqon | 0.001mA | |
Axagal | 0.001° | |
Bwaqtiga shaqada | Mcutubka 8hannagaa leh, sanduuqa muunada danabka 12saacadood | |
Wfogaanta gudbinta aan fiicneyn | 1000mitir iyo wixii ka sareeya (madhan iyouaan lahayn) | |
Dmuuqaalka cutubka ugu weyn | 320×270×140mm | |
Hbaaritaanka ururinta oo la qabtay | 180×120×80mm | |
Miisaanka cutubka ugu muhiimsan | 4kg (aan lahayn qalab) |
Munug | 1pbarafka |
Sunug koronto | 1pbarafka |
Wunugga isgaarsiineed ee aan naxariis lahayn | 1pbarafka |
Mfiilada fududaynta ee hadda ah 3-waji iska caabin ah | 1pbarafka |
Sfiilo koronto oo 3-waji ah | 1pbarafka |
Ofiilada utput ee cabbirka mitirka hadda | 1pbarafka |
Gxadhig wareegsan | 1pbarafka |
Awoodxadhig | 1pbarafka |
Charger | 1pbarafka |
Fisticmaal | 3pcs |
Prinji warqad | 1roll |
Alligator Clip | 8pcs |
Warbixinta tijaabada | 1 gabal |
Isticmaale'hagaha | 1 gabal |