GDYZ-301 Zinc Oxide Qalabaynta Qalabaynta
1. 800*480 midabka LCD taabashada shaashadda, oo leh daabacaha kuleylka xawaaraha sare leh.
2. Bandhig sawir leh, is-dhexgal dareen leh, fududahay in la shaqeeyo oo la isticmaalo goobta.
3. Gudbinta wireless fog fog.Masaafada gudbinta wireless-ka ee PT in ka badan 400m (2000m waa la beddeli karaa).
4. Ku habboon in lagu baaro xaalado kala duwan sida hillaaca korontada ama aan lahayn, shaybaadhka.
5. Tijaabi saddex weji hadda, saddex weji oo danab isku mar ah, ka hufan.
6. Koronto xoog leh oo gudaha ah kuma jirto, danab aan ka badnayn 12V.Dareemayaasha hadda jira iyo kuwa danabku gabi ahaanba waa go'doon, ammaan ah oo la isku halayn karo.
7. Taageerida muunad danab kala duwan: 1. Xarig;2 wireless;3. Koronto la'aan;
A. Silig: gudbinta signalka dhijitaalka ah oo leh fiilo kaas oo calaamaduhu ka yimi dabaylaha mitirka ee PT;
B. Wireless: Calaamadaha dhijitaalka ah gudbinta bilaa-waayirka ah ee calaamaduhu ka yimi dabaylaha mitirka ee PT;
C. Aan koronto lahayn: looma baahna in laga helo signalka PT terminalka.Isticmaal xisaabinta software si aad u hesho heerka tamarta.
8. La dhisay-in awoodda sare leh Li-batteri, ku haboon meel koronto la'aan.
9. Waxay qabataa qalab qalabaysan oo ku dhejisan iyo nidaamka qalliinka, waxay ballaarin kartaa hawlaha dib-u-ciyaarista maqalka iyo muuqaalka iyo hawlaha madadaalada ciyaarta.
10. Aaladda waa la shidi karaa oo waa la dami karaa wakhti kasta, kaas oo ka xasilan marka loo eego qalabka kumbiyuutarka warshadaha leh oo ah madal hardware ah, mana fududa in uu burburo oo nidaamku burburo.
11. Lagu rakibay deked USB ah si ay u taageerto dhoofinta xogta U disk.
12. Kaarka SD oo lagu dhex dhisay 4GB, waxa uu kaydin karaa xog badan oo tijaabo ah, waxaanu leeyahay hawlo ay ka mid yihiin maaraynta xogta iyo kaydinta.
13. Soo noqnoqoshada muunada xawaaraha sare, tignoolajiyada farsamaynta calaamadaha dhijitaalka ah ee horumarsan, waxqabadka ka hortagga faragelinta xooggan, natiijooyinka cabbirka saxda ah ee sare.
14. Iyada oo aan boodhka lahayn, aan biyuhu lahayn, sanduuqa caagga ah ee ka hortagga daxalka, cabbir yar, miisaan fudud, si fudud loo qaadi karo.
1. Korontada
Taageerada adabtarada korantada dibadda (12V/2A) iyo habka korantada batteriga gudaha;
2. Cabbirka cabbirka
Leakage Iminka (RMS) 0-10mA (la qiyaasi karo);
Voltage (RMS) 30-100V (la qiyaasi karo).
3. Cabbirka saxnaanta
Hadda: wadarta hadda> 100μA, ± 2% akhrinta ± 1 nambar;
Voltage: Calaamadaha korantada tixraaca> 30V
Xarig: ± 2% akhrinta ± 1 nambar;
Wireless: ± 5% akhrinta ± 1 nambar;
4. cabbirada cabbirka
Diidashada wadarta qaabka mowjadda hadda jira, hirka aasaasiga ah ee RMS, qiimaha ugu sarreeya.
Qaybta iska caabinta ee mawjada aasaasiga ah ee RMS ee daadinta hadda, 3, 5, 7 jeer RMS.
Qaybta iska caabinta qiimaha ugu sarreysa ee hadda, oo ay ku jirto qiimaha ugu sarreeya ee Ir+, qiimaha ugu sarreeya Ir-.
Mowjadda aasaasiga ah ee hadda awoodda leh, wadarta tamarta, farqiga xagal hadda oo buuxa.
Voltage RMS
Isticmaalka korontada ee xiraha.
5. Habka muunadaynta danabka tixraaca
Isku xirka fiilada: 20m (waa la kordhin karaa);
Isku-xidhka wireless-ka:> 400m (waa la kordhin karaa);
6. Halbeegga baytari
Waqtiga dallacaadda> 6 saacadood
Waqti shaqo oo joogto ah> 4 saacadood
Wakhtiga shaqada ee joogtada ah> 8 saacadood
7. Cabirka:360 * 260 * 140mm (martigeliyaha);420 * 330 * 200mm (Kiiska Qalabka ah);
8. Miisaanka:5kg (martigeliyaha);9kg (kiis dheeri ah);
Jaantuska 1 Gudida Martida
1. Dekadda dhulka hooseysa 2. 0-2mA gelinta hadda jirta 3. 2-10mA gelinta hadda
4. Dhuuqaha anteenada 5. Dekadda wada shaqaynta bilaa-wireless-ka
7. Badhanka daaran/Dami 8. Dallacaadda dekedda 9. Tilmaamaha isha
10. Tilmaamaha Korontada 11. Fan 12. USB interface 13. Midabka LCD screen 14.Printer
Jaantuska 2 PT Voltage Emitter
1. Badhanka ON/Dami 2. Deked ku dallaca 3. Tilmaamaha Korontada
4. Nuugista anteenada 5. Tilmaamaha isha 6. Dekedda anteenada
7. Dekadda dhulka hoostiisa ah 8. Deked isgaadhsiineed oo ka dhaxaysa martigeliyaha iyo PT danabka hawada sare 9. PT danab gelin
Martigeliyaha | 1pc |
Kiis dheeri ah | 1pc |
PT-ga hawada sare | 1pc |
Fiilada tijaabada ee hadda | 3pcs |
Xadhkaha tijaabada korantada | 1pc |
Fiilada dhulka hooseysa | 2pcs |
Isgaarsiintafiilo | 1pc |
Anteenada | 2pcs |
Dameeraha | 2pcs |
Warqad daabacan | 2 duub |
Isticmaale'smsannadkii | 1pc |
Warbixinta tijaabada | 1pc |