Waxaa jira tiro badan oo qalab koronto ah oo ku jira nidaamka korantada, nidaamka tareenada iyo macdanta dhirta petrochemical ee waaweyn iyo shirkadaha, dahaarka gudaha inta badan waa dahaarka saliid ka buuxo.Awoodda korantada ee saliidda dahaarka ayaa ah tijaabo joogto ah oo qasab ah.Si loo daboolo baahiyaha suuqa, shirkadeena waxay soo saartay oo soo saartay taxane ah tijaabiyeyaal awood dielectric saliid dielectric ah iyadoo loo eegayo heerka IEC156" Saliida Insulating-go'aaminta xoogga dielectric" iyo heerka warshadaha qaranka DL-474 · 4-92DL/T596 -1996" Koodhka tijaabada ee ka hortagga qalabka korontada".
Qalabkani wuxuu u qaataa microcomputer-ka hal-chip ka ah xudunta u ah, wuxuu gartaa dhammaan otomaatigga imtixaanka, wuxuu leeyahay saxnaanta cabbirka sare, wuxuu si weyn u wanaajiyaa hufnaanta shaqada, wuxuuna si weyn u yareynayaa xoogga shaqada ee shaqaalaha.Isla mar ahaantaana, qalabku wuxuu leeyahay muuqaal is haysta oo ku habboon in la qaado.
●Waxay qabataa microprocessor si ay si toos ah u dhamaystirto hawlaha kor u qaadista, qabashada, walaaqa, static, xisaabinta, daabacaadda, iwm.
●Koobka saliidda ee aaladda waxaa sameeyay hal mar oo lagu shubay dhalo gaar ah, taas oo ka hortagaysa faragelinta sida daadinta saliidda.
●Naqshadeynta muunadda-sare ee gaarka ah ee aaladda ayaa u oggolaanaysa qiimaha tijaabada inuu si toos ah u galo beddelaha A / D, isaga oo iska ilaalinaya khaladaadka ka dhashay wareegga analoogga, iyo samaynta natiijooyinka cabbirka mid sax ah.
●Heerarka fulinta tijaabada agabka waxaa ka mid ah halbeegyada warshadaha, heerar qaran iyo heerar shisheeye, hawlgalkuna waa mid fudud oo habboon.
●Iyada oo koronto-badan, hadda-badan, xad iyo ilaalin kale si loo xaqiijiyo badbaadada hawl-wadeenada.Oo wuxuu leeyahay awood xoog leh oo ka-hortagga faragelinta iyo ku habboonaanta korantada wanaagsan.
●Korontada wax soo saarka: 0-80kV
●Heerka qallooca awoodda: <1%
●Awoodda: 1.5kVA
●Koobka saliidda: 240ml
●Saxnaanta cabbirka: ± 3%
●Korontada oo kordhaysaheerka: 2kV/s, 3kV/s optional , qalad: 0.2kV/s
●Galinta awoodda: AC220V± 20%, 50Hz±5Hz
●Awoodda: <200W
●Heerkulka shaqada: 0-40 ℃
●Qoyaanka: <85% RH
●Cabirka: 430*350*370mm
Qalabka GDOT-80C | 1 gabal |
Koob saliid (250ml) | 1 gabal |
Xadhiga korantada | 1 gabal |
Fiilada dhulka | 1 gabal |
Fiyuuska kaydka ah | 2 gabal |
lowska walaaqaya | 2 gabal |
Heerka 2.5mm | 1 gabal |
Tweezer | 1 gabal |
Warqad daabac | 1 duub |
Tilmaamaha isticmaalaha | 1 koobi |
Warbixinta tijaabada warshadda | 1 koobi |
Electrode kale waa ikhtiyaari