GD6900 Awooda iyo Tijaabada Factor Factor
GD6900 waxay cabbirtaa awoodda iyo faa'iidada khasaaraha dielectric (tgδ) ee qalabka korantada sare.Waa qaab-dhismeed isku-dhafan, buundada tijaabada khasaaraha dielectric-ku-dhisan, sahay koronto oo la hagaajin karo inta jeer ee is-beddelka ah, kororka beddelka iyo capacitor-ka SF6.
Isha danab sare waxaa dhaliya qalabka inverter-ka gudaha, kaas oo loo isticmaalo tijaabinta shayga tijaabinta ka dib kobcinta transformerka.Haddii lagu daro koob daaha ah iyo qalabka xakamaynta heerkulka, luminta dielectric ee saliidda daboolka waa la tijaabin karaa.
●Taabo bandhiga shaashadda LCD.
●Cabbirka caabbinta dahaarka: Qalabka tijaabada iska caabbinta dahaarka ee ku dhex jira, wuxuu samayn karaa iska caabbinta Insulation (IR), saamiga nuugista (DAR), index polarization (PI).
●Chip kalandarka iyo kaydinta weyn ee gudaha.U keydi natiijada imtixaanka iyadoo loo eegayo nidaamka waqtiga, hubi diiwaanka taariikhda oo daabac natiijada.
●Xogta qalabka waxaa lagu dhoofin karaa U disk.
●Qaab tijaabo ah oo badan, oo leh habab gudaha danab sare leh, ka baxsan danab sare, heerka gudaha, heerka dibadda, GST/UST, is-xakamaynta.Korantada sare (in ka badan 10kV) tijaabada khasaaraha dielectric waxaa lagu samayn karaa xaaladda heerka dibadda ka baxsan danab sare.
●Tijaabi CVT buuxda oo shaabadaysan (Beddelka Voltage Capacitive) C1 iyo C2 khasaaraha dielectric iyo awoodda isku mar.Sidoo kale tijaabi saamiga isbeddelka CVT iyo farqiga xagasha danab.
●Khasaaraha dielectric iyo qiimaha awoodda ee C0 ee cidhifka sare ee CVT waxa lagu qiyaasi karaa iyadoo la isticmaalayo habka gaashaanka ee gadaale.
●Digniinta muunad xawli sare leh.Inverter iyo muunad wareegga gudaha waa la kontoroolo digitized.Korontada wax soo saarka ayaa si joogto ah loo hagaajiyaa.
●LCR cabbir toos ah.Inductance, capacitance, caabbinta, xagal waa la qiyaasi karaa oo la soo bandhigi karaa.
●Ilaalinta dhowrka ah ee isbedbeddelka korantada gelinta, wareegga gaaban ee soo-saarka, koronto-dhaafka ah, hadda-badan, heerkulka, sugan oo la isku halayn karo.Dhanka kale, waxay leedahay shaqada tijaabada dhulka, kor u qaadista danabku lama ogola qalabka aan dhulka dhigin.
●Looma baahna in la burburiyo sunta HV si loo cabbiro lumitaanka korantada iyo awoodda CVT.
●Soo noqnoqda waxaa loo bedeli karaa 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.
Xaaladda shaqada | -15 ℃ ~ 40 ℃ | RH<80% | ||||||
Mabda'a ka-hortagga faragelinta | Beddelka soo noqnoqda | |||||||
Korontada | AC 220V± 10%, 50/60Hz | Generator waa la isticmaali karaa. | ||||||
Wax soo saarka tamarta sare | AC 0.5KV ~ 10KV (12kV ikhtiyaari ah) | 0.1kV kasta | ||||||
Saxnaanta | 2% | |||||||
Max.hadda | 200mA | |||||||
Awood | 2000VA | |||||||
Awoodda is-xakamaynta | AC 0V~50V/15A | 50Hz, 60Hz hal jeer 45HZ/55HZ 47.5HZ/52.5HZ 55HZ/65HZ 57.5HZ/62.5HZ Soo noqnoqoshada tooska ah | ||||||
Qaraarka | tgδ: 0.001% | Cx: 0.001pF | ||||||
Saxnaanta | ∆tgδ: ± (akhrinta*1.0%+0.040%) | |||||||
∆C x: ± (akhrinta*1.0%+1.00PF) | ||||||||
Qiyaasta kala duwan | tgδ | Xad la'aan | ||||||
C x | 15pF <Cx < 300nF | |||||||
10KV | Cx <60 nF | |||||||
5KV | Cx <150 nF | |||||||
1KV | Cx <300 nF | |||||||
Imtixaanka CVT | Cx <300 nF | |||||||
Qiyaasta LCR | L>20H (2kV) | R>10KΩ(2kV) | ||||||
Saxnaanta cabbirka LCR | 0.1% | Qaraarka | 0.01 | |||||
Kala duwanaanshaha saamiga CVT | 10 ~ 10000 | |||||||
Saxnaanta saamiga CVT | 0.1% | |||||||
Xallinta saamiga CVT | 0.01 | |||||||
Iska caabin dahaarka | Danab sare oo DC ah | 5 ~ 10kV | Saxnaanta | ± (2%* Akhriska +10V) | ||||
saxnaanta IR | 100kΩ-1000GΩ: <5% (tijaabada danab aan ka yarayn 250V) 100GΩ-1000GΩ: 10% (tijaabada danab aan ka yarayn 10000V) | |||||||
Cabirka | Cutubka ugu muhiimsan: 350(L)×270(W)×270(H) | |||||||
Sanduuqa Agabka: 350(L)×270(W)×160(H) | ||||||||
Awoodda xusuusta | 200 oo kooxood, kaydinta diskka USB-ga waa la taageeray. | |||||||
Miisaanka | Cutubka ugu weyn: 22.75Kg | |||||||
Sanduuqa Agabka: 5.25Kg |
Tijaabiye | 1 set |
Kiiska agabka | 1 gabal |
Tijaabada cas ee HV 8m | 1 gabal |
Ledhka tijaabada madow ee LV 8m | 1 gabal |
Xadhkaha korantada 1.8m | 1 gabal |
CVT Isku xidhka rasaasta 5m | 1 gabal |
Hogaaminta dhulka 2m | 1 gabal |
Warqad daabac | 2 duub |
10A fiyuus | 3 xabbo |
Tilmaamaha Isticmaalaha | 1 koobi |
Warbixinta Imtixaanka Warshada | 1 koobi |
Qalabka ikhtiyaariga ah | |
Unugga Baaritaanka Saliidda | 1 pc |
Xakamaynta kuleylka | 1 pc |
Iyada oo leh unugga tijaabada saliidda iyo kantaroolaha kuleylka, isticmaaluhu wuxuu tijaabin karaa tan delta dareeraha dielectric sida saliidda beddelka.
Xakamaynta kuleylka
Weelka saliidda