GDKH-12 Dib-u-kicinta baytariga aysiidhka rasaasta
Qalabku waa qalab gaar ah oo lagu hawlgelinayo baytari-asiidh-asiidh ah oo valve- nidaamsan oo leh danab batari ah 2V, 6V, ama 12V iyo awoodda gadaal u ah sababtoo ah crystallization sulfide of saxan elektrode ah.Iyadoo "firfircooni" iyo "hubi dheecaanka", "ku dallacaadda tooska ah" iyo hawlaha kale ee batteriga.
Qalabkani waxa uu qaadanayaa mabaadi'da tignoolajiyada sare ee tijaabada ah, waxana uu sameeyay horumaro isdaba joog ah oo ku saabsan cilmi baarista iyo adeegsiga tignoolajiyada cusub, aaladaha cusub, agabka cusub, iyo hababka cusub.Waxay samayn kartaa hubinta dheecaanka dareeraha ee xaaladda dhabta ah ee baytariyada dib u dhaca ee kala duwan, iyo saddex marxaladood oo otomaatig ah ku dallacaadda ama wareegyo badan ayaa loo dejiyey inay dallacaan oo ay sii daayaan batteriga marar badan, si walxaha firfircoon ee ku guuldareysta saxanka batteriga uu dib u hawlgeliyo, iyo awoodda batteriga gadaal ayaa la kordhiyaa.Waxa kale oo ku qalabaysan software-ka codsiga PC-ga si loogu shubo xogta la ururiyey kombayutarka si loo baadho kala duwan.
Qalabku wuxuu leeyahay awood sare, cabbir yar, miisaan fudud, iyo software dhamaystiran oo maaraynta xogta kombuyuutarka martida loo yahay.Is dhexgalka mashiinka-mashiinada saaxiibtinimo iyo saaxiibtinimo ayaa si weyn u yareynaya tijaabinta maalinlaha ah iyo dayactirka shaqada batteriga waana kaaliyaha ugu fiican ee dayactirka batteriga.
●Qalabku wuxuu qabtaa hawlgalka shaashadda taabashada, interface-ka waxaa si toos ah loogu shaqeyn karaa qalin taabashada ama farta.Waxaa jira laba siyaabood oo lagu kaydiyo xogta: kaydinta gudaha iyo kaydinta kaarka SD dibadda.
●Iyada oo koronto-badan, hadda-badan, kuleyl badan iyo hawlaha kale ee ilaalinta.
●Hawsha kicinta: Marka batarigu offline yahay, batteriga kelida ah waa la hawlgelin karaa.Ka hor inta aan la kicin, deji tirada wareegyada firfircoonida, kharashka hal-abuurka hal-abuurka ah iyo wakhtiga sii-deynta, ilaalinta ilaalinta iyo xuduudaha kale, qalabku wuxuu si toos ah u fulin doonaa shaqada firfircoonida;oo soo bandhig danabka batteriga, dallacaadda / soo-dejinta hadda, awoodda dallacaadda / soo-dejinta, wakhtiga dallaca / soo-dejinta iyo xogta kale ee waqtiga dhabta ah;Ka dib marka wareegtada firfircoonida ee hore loo dejiyay la dhammeeyo ama shaqada la joojiyo gacanta, habka hawlgelinta waa la joojin karaa.
●Shaqada soo daynta: Marka batteriga uu offline yahay, loo isticmaalo culayska beenta ah ee caqliga leh si uu u sameeyo dheecaan joogto ah oo hadda socda.Deji "waqtiga soo daynta", "waqtiga sii deynta", "awoodda daadinta", "korontada joojinta" iyo cabbirro kale, qalabkuna wuxuu si toos ah u fulin doonaa shaqada dheecaanka, soo bandhigida waqtiga-dhabta ah ee dareeraha hadda, awoodda batteriga, danab batteriga, waqtiga sii deynta iyo xog kale;marka batteriga uu gaaro shuruudaha joojinta shaqada ama joojinta macmalka ah ee shaqada waxay joojin kartaa baaritaanka sii deynta.
●Shaqada dallacaadda: Marka uu batteriga ku jiro on-line sabeynaya ama offline, batteriga si toos ah ayaa loo dallaci karaa.Deji halbeegyada sida "dallacaadda hadda", "waqtiga dallaca", iyo "korontada joojinta", qalabkuna wuxuu si toos ah u gudan doonaa shaqada dallacaadda.Iyo soo bandhigida waqtiga-dhabta ah ee dallacaadda hadda, awoodda batteriga, korantada batteriga, waqtiga dallacaadda iyo xogta kale, marka batteriga uu gaaro shuruudaha dallacaadda hore ee joojinta ama joojinta macmalka ah ee hawlgalka waxay joojin kartaa dallacaadda.
●Shaqada tijaabada caabbinta degdega ah ee gudaha: (ikhtiyaar) ka dib baakidhka batteriga laga saaro nidaamka, waxay qaadataa 1 ilaa 2 daqiiqo kaliya si loo cabbiro awoodda qiimaynta batteriga, iska caabbinta gudaha, iwm.
●Shaashada LCD midabka sare leh.
●Software-ka maaraynta xogta kombuyuutarka martida loo yahay waa mid awood badan oo saaxiibtinimo leh.Waxay bixisaa maareynta xogta, daabacaadda, falanqaynta, tirakoobka warbixinta, soo saarista warbixinta tijaabada tooska ah iyo hawlo kale.
Nooca cabirka tamarta unugga hal unugga ah | 2V/6V/12V |
Halbeegga cabbiraadda tamarta unugga | 2V: 0 ~ 3V 6V/12V: 0~16V |
Xallinta korantada unugga keliya | 2V: 0.001V;6V/12V: 0.001V |
Saxnaanta cabbiraadda korantada | 0.5% |
Dallacaadda/saarida xadka hadda jira | 2V: 1A~ 100A 6V: 1A~ 30A 12V: 1A~ 30A |
Ku dallaci/ shubista saxnaanta xakamaynta hadda | 1% |
Kala duwanaanshaha hubinta awoodda batteriga | 2V: 20Ah~ 1000Ah 6V: 20Ah ~ 300Ah 12V: 20Ah ~ 300Ah |
Danab shaqaynaysa | AC 220± 15% |
Wareejinta kulaylka | Qaboojinta hawada qasabka ah |
Deegaanka shaqada | Heerkulka: 0℃ ~ 40℃ qoyaan: 20% ~ 80RH |
Xaaladaha kaydinta | -20 ℃ ~ + 70 ℃ kaydinta baakadaysan |
Bandhig | Shaashada LCD iftiin sare |
Cabirka | 401mm * 176mm * 273 mm |
Miisaanka | 15kg |