GD-875/877 Kaamerada Infrared Thermal
●Kontoroolka tooska ah ama gacanta ee cabbirka heerkulka midabka
●℃, °F iyo unugyada cabbirka K
●11 isticmaale palette midab la dooran karo
●9 isticmaale luqadaha la dooran karo
●Cabbirka heerkulka kulul
● Cabbirka barta heerkulka qabow
●4 cabbirada dhibcaha la dhaqaajin karo
● Dejinta digniinta heerkulka sare
● Milicso - Magdhawga heerkulka oo muuqda
●2x zooml dhijitaal ah
●Shaashada qabooji si aad u daawato sawirka hadda socda
●Fiidiyowga - NTSC ama PAL
●Qiyaasta heerkulka 3 meelood
●2-line heerkulka cabbirka
●Saxitaanka heerkulka gadaasha
● Kaydinta sawirka kaadhka TF
●CMOS sawirka iftiinka muuqda iyo kaydinta
●Cod duubis ah
●Qaylo-dhaan heersare ah
●Sixitaanka heerkulka, sixitaanka dhimista cabbirka
●lagu dhisay liiska agabka caadiga ah
Shayga | Halbeegga | |
Baaraha | Nooca | Nooca kulaylka yar ee diyaaradda focal aan qaboojin |
Pixel | 160*120 | |
Muuqaalka Pixel | 25μm | |
Mawjada dhererka | 8-14μm | |
Inta jeer ee muunada | 50Hz | |
Dareenka kulaylka | 0.06℃@30℃ | |
Lens | Goobta Muuqaalka | 25°* 19° |
Masaafada shay ee ugu dhow | 10cm | |
Habka diiradda | Diiradda gacanta | |
Muraayada fidsan | 0.5x / 2x, ikhtiyaari ah | |
Nooca Interface | Isku xirka Bayoneet | |
Waxqabadka sawirka | Xallinta meel bannaan | 2.72 garaam |
zoom elegtaroonig ah | 2X | |
Kaamirada iftiinka muuqata | module CMOS | |
Heerka jir | 50/60Hz, ikhtiyaari ah | |
Soo saarista muuqaalka | PAL / NTSC, ikhtiyaari ah | |
Muujinta sawirka | Shaashada LCD | 3.5 ″ TFT LCD,320*240,midab leh |
Midabka midabka | 11 palette midab leh oo laga dooran karo | |
Hagaajinta sawirka | Isbeddelka tooska ah / gacanta ee isbarbardhigga iyo dhalaalka | |
Muujinta sawirka | Si degdeg ah u kala beddel sawirada infrared iyo kuwa muuqda | |
Habaynta Sawirka | si toos ah / buug-gacmeed | |
Cabbirka | Kala duwanaanta heerkulka | -20℃~+350℃ |
Saxnaanta heerkulka | ±2℃or ±2% akhriska, qaado qiimaha weyn | |
hagaajinta heerkulka | Auto (waqti gaaban, waqti dheer, waqti gaar ah) / buug-gacmeed | |
Habka cabbirka | Dhibcaha la dhaqaajin karo (illaa 4 dhibcood), meelaha la guuri karo (ilaa 3 aag, cabbirka heerkulka celceliska ee la dooran karo, ugu badnaan / ugu yaraan raadraaca heerkulka), khadadka la dhaqaajin karo (illaa 2 xariiq), ugu badnaan shaashad buuxda / daba-galka heerkulka ugu yar, soo bandhigid ilaa 5 Kooxaha Xogta;Falanqaynta isothermal, falanqaynta kala duwanaanshaha heerkulka, dabagalka heerkulka, alaarmiga heerkulka (cod, midab) | |
sixitaanka dareenka | La hagaajin karo 0.01 ilaa 1.0 (kor u kaca 0.01) ama ka dooro liiska agabka hore loo sii qeexay | |
Saxitaanka heerkulka asalka ah | si toos ah | |
Sixitaan gudbinta hawada | Toos ah, oo ku salaysan fogaanta la soo galay, qoyaanka deegaanka iyo heerkulka deegaanka | |
Dejinta shaqada | Taariikhda/waqtiga, unugga heerkulka ℃/℉/ K, luqadda | |
Kaydinta sawirka | kaadhka kaydinta | 8GB Micro TF kaarka, taageero ilaa 16GB |
Nooca kaydinta | Kaydinta gacanta / si toos ah;hal qaab oo infrared image ah, infrared iyo sawirka iftiinka la arki karo | |
Qaabka sawirka kulaylka | Qaabka JPEG oo leh xogta cabbirka infrared cayriin | |
Qaab sawirka iftiinka muuqda | qaabka JPEG | |
Xusuusin cod | 60 ilbiriqsi (ku keydi sawirka) | |
Korontada | Battery | Batari lithium ah oo dib loo soo celin karo, la bedeli karo |
Waqtiga shaqada ee batteriga | Si joogto ah u shaqaynaysa in ka badan 4 saacadood | |
Habka dallacaadda | Ku dallacaadaha smart ama dallacaadda randomka ah ( adabtarada korantada AC ama sahayda gaadhiga 12V) | |
Waqtiga dallacaadda | Dallacaadda aan tooska ahayn ee saacadaha 1.5 in ka badan 50% awoodda | |
Habka kaydinta awooda | Jiif toos ah, xidhid toos ah | |
Interface | Interface kaadhka xusuusta | Micro SD (TF) booska |
USB interface | Haa, wareejinta xogta | |
Interface awood sahayda | Haa (DC 12V) | |
Interface wax soo saarka video | Haa | |
Kuwo kale | Makarafoon | Lagu dhex dhisay |
Buzzer | Lagu dhex dhisay | |
meeleeyaha laser | Casaan, 1mw/635nm, fasalka 2, IEC60285 | |
Dunta Tripod | 1/4 "-20-UNC | |
Tareenka gacanta | Waxaa lagu rakibi karaa labada dhinac | |
koofiyadda muraayadda | Haa | |
Sunshade | Haa, ikhtiyaari | |
Deegaanka | Heerkulka shaqada | -15℃~+50℃ |
Heerkulka kaydinta | -40℃~+70℃ | |
Qoyaanka | ≤95% aan shubin | |
Heerka ilaalinta | IP54 | |
Iska caabbinta saamaynta | 25G, IEC68-2-29 | |
Ka-hortagga gariirka | 2G, IEC68-2-6 | |
Dayrta | 2 mitir | |
Jireed muuqaal | Cabirka | 105*230*245 mm |
Miisaanka | 980g |
Fariintaada noo soo dir:
Halkan ku qor fariintaada oo noo soo dir