Transformer Gaaska Saliida Chromatography Nidaamka Kormeerka onlaynka ah
GDDJ-DGA Transformer Oil Gas Analyzer waa qalab online ah oo lagula soconayo gaaska kala diri ee saliidda beddelka ee ku salaysan tignoolajiyada chromatography gaaska.Cilada suurtagalka ah ayaa la go'aamiyaa, sii daa digniinta sida ku cad qiimaha hore loo dejiyay iyada oo loo marayo nidaamka ogaanshaha khabiirka.
Qalabku wuxuu qaataa tignoolajiyada muunada kontoroolka ee qaybsan wuxuuna leeyahay is-aqoonsi iyo hawlo dib-u-soo-kabasho.Qayb kasta oo hawleedku waa isku-xidhnaan daciif ah, madax-bannaani shaqaynaysa, qaadashada qaab-dhismeedka rack, fududaynta dayactirka injineernimada.
●Dayactir la'aan, looma baahna in la beddelo dhululubada gaaska.
●Ogaanshaha khadka-fiirsashada iyo heerka kobaca ee H2, CO, CO2, CH4, C2H4, C2H2, C2H6.
●Naqshad qaabaysan iyo qaab-dhismeed is haysta, oo u fudud dayactirka, oo leh fidinta sare, ayaa si fudud loogu dari karaa qalabka kale ee kormeerka.
●Habka muunad wareegga nadiifinta tirada, si ay u muujiso xaaladda gaasta kala diri ee saliidda beddelka.
●Tignoolajiyada degeyska faakuumka ee aan nadiifka ahayn, looma baahna bamka faakuumka iyo hagaajinta isku halaynta iyo xasiloonida nidaamka.
●Tiirka chromatographic kakan ee gaarka ah, si loo hagaajiyo heerka kala soocida halabuurka gaaska.
●Baaraha khaaska ah ee toosan, xogta la socodka waa mid dhab ah oo la isku halayn karo, natiijooyinka imtixaanku aad bay ugu dhow yihiin xogta shaybaadhka.
●Unug madaxbanaan oo ku dhex jira chassis si loo xakameeyo heerkulka iyo qoyaanka, si meesha looga saaro saamaynta gobolka iyo xilliyeed.
●Iyada oo saxnaanta helitaanka xogta sare, waxay qaadanaysaa △-ε 24-god ADC iyo filtarka dhijitaalka ah.Waxay isticmaashaa jaanis otomaatig ah si ay u ururiso spectrogram.
●Iyada oo leh bandhig xog oo kala duwan iyo qaabab weydiin, warbixin iyo garaaf isbeddel.Xogta taariikhiga ah waxaa la keydin karaa ilaa 10 sano.
●La qabsiga deegaanka oo xoog leh, codsi guul leh oo qabow, heerkul sarreeya, huurka sare, aagga sare ee sare.
●Awood xoog leh oo ka-hortagga faragelinta, ku-habboonaanta korantada ayaa qancin karta heerka ku habboon.
●Laba heer oo ah shaqada alaarmiga, calaamada alaarmiga waa la kala qaadi karaa.
●Wareegga falanqaynta degdega ah, wareegga kormeerka ugu yar waa 40 daqiiqo, waxaa dejin kara isticmaalayaasha.
●Tiknoolajiyada soo celinta saliidda oo dhameystiran, inta lagu gudajiro geeddi-socodka deg-degga ah, muunadda saliiddu lama xiriirto gaaska chromatogram-ka, isticmaalka habab kala duwan oo lagu xakameynayo, si loo hubiyo in soo-celinta soo-celinta ee muunadda saliidda ay si buuxda u buuxiso shuruudaha.
●Nidaamka ogaanshaha nidaamka oo la xoojiyay, natiijooyinka waxaa lagu bixiyaa habka saddex-geesoodka ah ee la hagaajiyay, Habka saddex-xagalka David iyo habka jaantuska cube.
●Iyadoo habab kala duwan oo isgaarsiineed lagu wareejinayo xogta, RS485, IEC61850, GPRS wareejinta wireless-ka iyo fariinta gaaban ayaa lagu dabaqaa wareejinta xogta.
●Taageer isku xirka Ethernet/optical, wareejinta xogta, kontoroolka aaladda iyo dejinta cabirka oo leh habayn buuxda iyo kontorool fog.
●Saliidda/gaaska is-habaynta baabuurta iyo hawlaha nadiifinta baabuurta ayaa diyaar ah.
heerkulka deegaanka | -40℃~+70 ℃ | ||
Qoyaanka deegaanka | Qoyaanka qoyaanka ah 5-95% (aan uumi lahayn) | ||
Cadaadiska Hawada | 80kPa-110kPa | ||
Korontada | AC 220V± 10%, 50Hz | ||
Qaybaha la socodka | H2, CO, CO2, CH4, C2H4, C2H2, C2H6, H2O, heerka korriinka iyo xoogga saarista | ||
Falanqaynta iyo shaqada ogaanshaha | U falanqee oo ku baadh xogta la socodka hab saddex-qaybood ah, Habka saddexagalka David iyo habka jaantuska cube.spectrogram asalka ah waa la keeni karaa. | ||
Min.Wareegga ogaanshaha | 40-60mins, isticmaale-qeexay, ugu talagal afar jeer maalintii. | ||
Habka muunada | Muunad baaskiil wadista, si ay u muujiso xaaladda dhabta ah ee gaasta gudaheeda. | ||
Habka loo kala saaro saliidda iyo gaasta | Nadiifinta degsiimada habka, dajinta saddex jeer si joogto ah. | ||
cimriga kaydinta xogta | ≥ 10 sano | ||
Tirada gaaska siday | Gaaska sidayaal iskiis u sameystay, oo aan kala go'in sanadka oo dhan.Looma baahna in la beddelo dhululubada gaaska. | ||
Ilaalinta gaaska | Qiyaasta kala duwan | Min.ogaanshaha | Khalad |
H2 | 2-2000 ppm | 1 ppm | ± 10% |
CO | 5-20000 ppm | 5 ppm | ± 10% |
CH4 | 0.2-2000 ppm | 0.2 ppm | ± 10% |
C2H4 | 0.2-2000 ppm | 0.2 ppm | ± 10% |
C2H6 | 0.2-2000 ppm | 0.2 ppm | ± 10% |
C2H2 | 0.2-2000 ppm | 0.2 ppm | ± 10% |
CO2 | 25-20000 ppm | 25 ppm | ± 10% |
H2O | 1 - 800 ppm | ||
Heerkulka saliidda | -40 ℃ ~ 200 ℃ | ||
Wadarta tirada hawada | 0.2-15% | ||
Wadarta kaarboonka | 1-8000 ppm | ||
Xasilloonida (khalad cabbirka) | Isla xaaladda tijaabada, khaladku kama badna 10% isla saamiga saliidda.(fiirin dhexdhexaad ah) | ||
Heerka IP | IP66 |
Dhererka | ≤3000m |
Heerkulka deegaanka | -10℃~+45℃(gudaha);-40℃~+70℃(dibadka) |
Max.kala duwanaanshaha heerkulka maalinlaha ah | 25℃ |
Max.qoyaan qaraabo | 95% (celcelis ahaan maalintii);90% (celcelis ahaan bishii) |
Cadaadiska hawada | 86kPa ~ 106kPa |
Awood ka hortagga naxdinta | Dardargelinta tooska ah 0.30g;dardargelinta toosan 0.15g |
Deegaanka rakibida | Ku rakibida gudaha.Qolka waa in lagu qalabeeyaa qaboojiyaha, oo aan lahayn gaashaan, iyada oo aan lahayn tallaabooyin ka hortag ah. |
Koronto la qiimeeyay (AC) | 220V/100V, qaladka la ogolyahay ± 20% (harmonics), wadarta heerka qallooca danab ≤8%. |
Koronto la qiimeeyay (DC) | 220V/110V, kala duwanaansho la ogol yahay ± 20%. |
Danab AC lagu qiimeeyay | 57.7V / 100V / 220V, awoodda xad dhaafka ah waa 1.2times ee danab lagu qiimeeyay, iskudarka ugu sarreeya ≥2. |
La qiimeeyay AC hadda | 1A/5A, awoodda culeyska xad dhaafka ah waa 1.2 jeer ee hadda la qiimeeyay, si joogto ah u shaqaynaysa, iskudarka ugu sarreeya≥3. |
Inta jeer ee la qiimeeyay | 50Hz, qalad la ogolyahay -5%~+5%. |
Korontada
Korontada nidaamka la socodka xaalada substation waa inuu ahaadaa mid badbaado leh oo la isku halayn karo, iyo qalabka lakabka kantaroolka saldhiga waa inuu ku shaqeeyaa 220VAC Koronto aan kala go' lahayn (UPS).Qayb kasta oo la socodka lakabka habsocodka waxa ku shaqeeya 220V AC system.
Ilaalinta hillaaca, dhulka, ka-hortagga faragelinta
Nidaamka la socodka xaalada substation waa inuu lahaadaa tillaabooyin ka ilaalinaya korontada xad dhaafka ah.
Ma jiro shabakad gooni ah oo u gaar ah nidaamka la socodka xaaladda.Marka loo eego mabda'a "hal-dhibcood oo dhulka ah", siligga dhulku wuxuu ku xiran yahay hal dhibic oo ka mid ah xariiqda ugu weyn ee saldhigga hoose.
Aaladda ilaalinta korantada ee ka badan waa in lagu rakibaa 220V AC koronto, khadka isgaarsiinta iyo dhamaadka hogaaminta shabakada dhulka, iyo cabbirada aaladaha ilaalintu waa in ay waafaqaan tusmada waxqabadka dahaarka ee qalabka.
Shassis-ka, armaajooyinka iyo lakabka ilaalinta fiilada ee nidaamka la socodka xaaladda waa in si la isku halleyn karo loo saleeyo.Xidhiidhka u dhexeeya lakabyada habka nidaamka kormeerka xaaladda, xidhiidhka ka dhexeeya lakabka habka iyo lakabka xakamaynta saldhigga, iyo xidhiidhka ka dhexeeya dekedaha isgaarsiinta ee qalabka waa in la go'doomiyo.
Qalabka waxaa lagu rakibay qol aan lahayn gaashaan koronto.Qalabka laftiisa waa inuu buuxiyaa shuruudaha faragelinta ka-hortagga-electromagnetic field iyo saamaynta korantada.Haddii ay dhacdo koronto koronto, koronto shaqeyn iyo cillad gaaban ee qalabka aasaasiga ah, qalabku waa inuusan si xun u shaqeyn, dhammaan qalabkuna waa inuu buuxiyaa shuruudaha soo socda ee ka hortagga faragelinta:
1) Dheecaan elektrostatic ah, waxay u hoggaansamaysaa GB/T 17626-4-2 fasalka 4.
2) Goobta shucaaca elektromagnetic-ka, waxay u hoggaansamaan GB/T 17626-4-3 fasalka 3.
3) Ku-meel-gaadhka degdega ah, waxay u hoggaansantaa GB/T 17626-4-4 fasalka 4.
4) Qalliinka, waxay u hoggaansantaa GB/T 17626-4-5 fasalka 3.
5) Ku-gudbinta soo-saarka korantada, waxay u hoggaansamaysaa GB/T 17626-4-6 fasalka 3.
6) Inta jeer ee awoodda korantada korantada, waxay u hoggaansamaysaa GB/T 17626-4-8 fasalka 4.
7) Goobta elektromagnetic ee garaaca wadnaha, waxay u hoggaansamaysaa GB/T 17626-4-9 fasalka 5.
8) Goobta birlabeed ee oscillating qoyan, waxay la jaanqaadeysaa GB/T 17626-4-10 fasalka 5.
9) Mowjadaha lulaya, waxay u hoggaansamaan GB/T 17626-4-12 fasalka 2 (deked calaamad).
Maya | Magaca Qalabka | Tilmaamaha | Qty | Odhaah |
1 | Transformer Oil Gas Online nidaamka la socodka | 535*600*1100 | 1 | |
2 | Flange | Iyada oo ku saleysan dekedda Transformer | 2 | |
3 | Tuubo bir ah oo aan lahayn | Φ6*30M | 1 | |
4 | Fiber indhaha | Multimode 4-core, 200M | 1 | |
5 | Sanduuqa Terminalka | 2 | ||
6 | Jumper | SC-SC | 2 | |
7 | Beddelaha Fiber | multimode | 1 | |
8 | fiilada Ethernet | 0.5M | 2 | |
9 | Isku dhufashada | M12*1.25M, Φ6 | 2 | |
10 | Isbalaarinta furka | M10*100 | 4 | |
11 | Furaha golaha | 2pcs | 1 | |
12 | Kaarka fiilada | 4pcs+ dhawr xadhig oo naylon ah | 1 | |
13 | Tuubo bir ah oo aan lahayn | Φ3*2M | 1 | |
14 | Dhuumaha dahaadhka iyo qaybaha kale | Tuubbada dahaarka Φ6*2M 4pcs | 1 |