HV HIPOT GDHG-201A Transformer Comprehensive CT/PT Analyzer (transformer soo noqnoqda beddelka volt-ampere sifada tijaabiyaha) waa qalab tijaabo ah oo gaar ah oo loo isticmaalo ilaalinta gudbinta iyo dahaarka korantada sare si loo tijaabiyo ilaalinta beddelayaasha hadda jira iyo beddelayaasha danab ilaalinta.Qalabku wuxuu adeegsadaa tignoolajiyada beddelka soo noqnoqda, hagaajinta kala duwanaanshaha tijaabada korantada, yaraynta miisaanka mashiinka oo dhan, waa aalad ku habboon in lagu beddelo tijaabiyaha voltammetry ee jira.
HV HIPOT GDHG-201A CT/PT Analyzer
Tilmaamaha Qalabka iyo Hawlaha
Transformer ilaalinta:
1. Habka cabbiraadda CT si toos ah ayaa loo xakameynayaa, xogta si toos ah ayaa loo duubayaa, qalooca volt-ampere si toos ah ayaa loo sawiraa.
1) Si toos ah u deji korantada ilaalinta hadda iyo ilaalinta, oo si toos ah u hagaaji tallaabada.
2) Adeegsiga tijaabada korontadda soo noqnoqda ee isbedbedelka ah, kala duwanaanshaha korantada imtixaanku waa mid ballaaran (10000V).
3) Si toos ah u bixi barta leexinta tixraaca (voltage, current)
2. 10% iyo 5% qalooca qaladka ayaa si toos ah loo sawiraa.
3. Soo ogow saamiga isbeddelka ee transformers-yada hadda jira ee la yaqaan oo cabbir saamiga isbeddelka beddelka beddelka hadda aan la garanayn.
4. Cabbir farqiga saamiga 100% iyo farqiga xagal ee dabaylaha ilaalinta ee beddelka-heerka ilaalinta hadda.
5. Habka cabbiraadda PT si toos ah ayaa loo xakameynayaa, xogta si toos ah ayaa loo diiwaangeliyaa, iyo qalooca volt-ampere si toos ah ayaa loo sawiraa.
6. Soo ogow saamiga is beddelka ee taransfoorayaasha danab ee la yaqaan oo cabbir saamiga isbeddelka beddeleyaasha tamarta aan la garanayn.
7. Cabbir cabbirrada culeyska wareegga labaad ee beddelayaasha hadda iyo korantada.
8. 320 * 240 shaashad weyn oo LCD ah. Xargaha iyo hawlgalku waa sahlan yihiin.
9. Xogta cabbiraadda kala duwan waa la kaydin karaa oo la daabici karaa, taas oo ku habboon isticmaalayaasha inay waydiiyaan.
Transformer-ka hadda ee cabbiraadda:
1. La kulan 1%-120% (S-heer) khaladka qeexida (farqiga xagasha, farqiga saamiga) ee cabbiraadda transformers-yada hadda jira iyadoo la raacayo cabbirka heerka heerka qaranka ee transformers hadda.
2. Buuxi cabbirka iyo bandhigga (sida ku cad cabbirka caadiga ah) qaladka dhibicda caadiga ah (farqiga xagasha, farqiga saamiga) ee hoos yimaada xadka sare ee culeyska iyo culeyska hoose ee isbeddelka hadda jira hal mar.
3. Soo ogow saamiga isbeddelka iyo kala-duwanaanta is beddelka hadda.
Haddii aad xiisaynayso HV HIPOT Transformer Comprehensive CT/PT Analyzer, fadlan nagala soo xidhiidh +86- 027-85568138