  • Qallafsanaanta dabaylaha beddelka - beddelka deegaanka

    Qallafsanaanta dabaylaha beddelka - beddelka deegaanka

    Qallafsanaanta maxalliga ah macnaheedu waa in wadarta guud ee gariiraddu aanay is beddelin, ama dhexroorka iyo dhumucda u dhiganta ee gariiradda aanay waxba iska beddelin meel ballaadhan;Kaliya lebbiska qaybinta cabbirka gariiradaha qaarkood ayaa isbeddelay, ama dhexroorka u dhigma keega gariiradda qaarkood ayaa isu beddelay mid yar oo e...
    Akhri wax dheeraad ah
  • Waa maxay sababaha "qayb qayb ka soo baxa"

    Waa maxay sababaha "qayb qayb ka soo baxa"

    Waxa loogu yeero "qeyb ka dareere" waxaa loola jeedaa dareere kaas oo qayb ka mid ah nidaamka dahaarka oo kaliya ay sii daayaan iyada oo aan la samaynin kanaalka dareeraha ah ee hoos yimaada ficilka beer koronto.Sababta ugu weyn ee qayb ka mid ah dareeraha ayaa ah marka dielectric-ku aanu labis ahayn, ...
    Akhri wax dheeraad ah
  • Waa maxay cawaaqibta ka dhalan karta fadhiid xumo?

    Waa maxay cawaaqibta ka dhalan karta fadhiid xumo?

    Wadarta iska caabbinta dhulka ee dhulka ama jidhka dabiiciga ah iyo iska caabbinta siliga dhulka waxa loo yaqaan caabbinta dhulka ee qalabka dhulka.Qiimaha iska caabbinta dhulka waxay la mid tahay saamiga korantada qalabka dhulka hoostiisa ee dhulka iyo c...
    Akhri wax dheeraad ah
  • Habka tijaabada ee tijaabiyaha iska caabbinta Dhulka

    Habka tijaabada ee tijaabiyaha iska caabbinta Dhulka

    U diyaargarowga tijaabada 1. Kahor intaan la isticmaalin, waa inaad akhridaa buug-tilmaameedka alaabta si aad u fahamto qaabka, waxqabadka iyo isticmaalka qalabka;2. Tiro agabka dheeriga ah iyo agabka looga baahan yahay baadhista iyo in awooda baytarigu ku filan tahay;3. xidhidhiyaha...
    Akhri wax dheeraad ah
  • Horudhaca Habka Cabbirka ee Transformer-ka Qayb Qayb ah

    Horudhaca Habka Cabbirka ee Transformer-ka Qayb Qayb ah

    HV Hipot GD-610C fogaanta ultrasonic qayb ka mid ah dareeraha dareeraha 1. Mitir korantada ama mitirka faragelinta raadiyaha si loo helo qaabka hirarka saxanka
    Akhri wax dheeraad ah
  • Sida loo sii daayo ka dib markii DC u adkeysanayo imtixaanka danab

    Sida loo sii daayo ka dib markii DC u adkeysanayo imtixaanka danab

    Habka soo daynta ka dib markii DC ay u adkaysato tijaabada danabka, iyo sida loo doorto iska caabinta dareeraha iyo usha dheecaanka: (1) Marka hore jar korontada tamarta sare.(2) Marka danabka muunadda la tijaabinayo uu ka hoos dhaco 1/2 ee tamarta tijaabada, ku soo bixi muunadda dhulka iyada oo loo marayo iska caabinta.(3...
    Akhri wax dheeraad ah
  • Waa maxay dhibaatooyinka ay tahay in fiiro gaar ah loo yeesho marka la isticmaalayo caabbinta dahaarka?

    Waa maxay dhibaatooyinka ay tahay in fiiro gaar ah loo yeesho marka la isticmaalayo caabbinta dahaarka?

    Waa kuwee dhibaatooyinka soo socda ee ay tahay in fiiro gaar ah loo yeesho marka la isticmaalayo caabbinta dahaarka?HV Hipot GD3000B Tijaabada Iska caabinta Dahaarka Marka hore, marka la tijaabinayo caabbinta dahaadhka shayga tijaabada, waxaan u baahanahay inaan ogaano awooda iyo heerka korantada shayga tijaabada, iyo com...
    Akhri wax dheeraad ah
  • Ka warran ilaalinta flashover?

    Ilaalinta Flashover waa hab ilaalin sare oo danab ah, kaas oo loo isticmaali karo ilaalinta flashover danab, ilaalinta flashover jabiyaha, insulating saliid flashover ilaalinta, iwm nidaamka korontada.Marka la soo koobo, ilaalinta flashover waa muujinta burburka tamarta.Waa maxay fl...
    Akhri wax dheeraad ah
  • Ahmiyada Tijaabada Bixinta Qaybeed

    Ahmiyada Tijaabada Bixinta Qaybeed

    Waa maxay dheecaanka qayb ahaan?Maxay qalabka korontadu ugu baahan yihiin baaritaanka qayb ka mid ah dareeraha?Qayb ka mid ah dareeraha korantada ee dahaadhka qalabka korontada, kaas oo ka dhici kara meel u dhow kirishbooyada ama meel kale, waxaa loo yaqaan dheecaan qayb ah.Sababtoo ah tamarta yar ee marxaladda hore ee qaybta ...
    Akhri wax dheeraad ah
  • Maxaan sameeyaa haddii heerka saliidda dahaadhka ahi aad u sarreeyo?

    Maxaan sameeyaa haddii heerka saliidda dahaadhka ahi aad u sarreeyo?

    Saliida dahaadhka ah (sidoo kale loo yaqaan saliidda beddelka) waa nooc gaar ah oo saliid dahaadh ah oo hubin karta shaqada caadiga ah ee beddelka.Marka transformer-ku uu socdo, xaaladaha caadiga ah, heerka saliidda beddelka ayaa isbeddelaya isbeddelka heerkulka saliidda beddelka.Marka...
    Akhri wax dheeraad ah
  • Muxuu tijaabiyaha iska caabbinta dhulka u baahan yahay inuu ka gooyo korantada gudaha

    Muxuu tijaabiyaha iska caabbinta dhulka u baahan yahay inuu ka gooyo korantada gudaha

    Qaar ka mid ah qalabka cabbiraadda iska caabbinta waxay u baahan yihiin in la gooyo cabbiraadda, halka kuwa kalena aysan u baahnayn, inta badan iyadoo ay ugu wacan tahay tixgelinnada soo socda.Haddii aan la go'in, xaaladaha soo socda ayaa dhici doona: HV Hipot GDCR3200C double-clamp multi-function grounding...
    Akhri wax dheeraad ah
  • Waa maxay macnaha cabbiraadda iska caabbinta DC ee Transformers?

    Waa maxay macnaha cabbiraadda iska caabbinta DC ee Transformers?

    Cabbirka Transformer ee iska caabbinta DC waa qayb muhiim ah oo ka mid ah tijaabada beddelka.Iyada oo la adeegsanayo cabbiraadda iska caabinta DC, waxaa suurtagal ah in lagu hubiyo in wareegga korantada ee transformerku uu ku jiro xiriir liita, alxanka xun, cilladda gariiradda iyo khaladaadka fiilooyinka iyo cilladaha isdaba jooga ah....
    Akhri wax dheeraad ah