Sida loo xalliyo dhibaatada koronto-dhaafka ah ee nidaamka tijaabada resonant ee inta jeer ee AC?

Sida loo xalliyo dhibaatada koronto-dhaafka ah ee nidaamka tijaabada resonant ee inta jeer ee AC?

Nidaamka tijaabada resonant AC ee inta jeer ee loo isticmaalo in lagu aqoonsado xoogga dahaarka ee qalabka korantada.Waa muhiim in la qiimeeyo in qalabka korantada la shaqayn karo iyo in kale.Sidoo kale waa hab muhiim ah oo lagu hubinayo heerka dahaarka qalabka lagana fogaado shilalka dahaarka.Sababtoo ah aaladda tijaabinta resonance-ka ee is-beddelka soo noqnoqda waxay si buuxda uga tarjumi kartaa xaaladda dhabta ah ee qalabka korantada ee ku shaqeeya tamarta AC, waxay si dhab ah oo waxtar leh u heli kartaa cilladaha dahaarka.

                                                    变电站变频串联谐振试验装置

HV HIPOT GDTF Taxanaha Isbeddelka Soo noqnoqda ee Nidaamka Imtixaanka Resonant AC

 

Sababo la xiriira mabda'a dhawaaqa ee uu qaatay aaladaha tijaabinta resonance ee taxanaha is-beddelka soo noqnoqda, korantada inta jeer ee wareegyada nidaamka iyo awoodda iyo falcelinta wareegga ayaa dhalinaysa dhawaaq.Korontada ku jirta capacitor-ka waxay gaartaa tamarta tijaabada.

Marka loo eego mabaadi'da kor ku xusan iyo xaaladda imtixaanka dhabta ah ee goobta, xad-dhaafka ah ee is-beddelka is-beddelka isdaba-joogga ah wuxuu guud ahaan ku dhacaa laba xaaladood, mid waa marka qalabku uu raadinayo barta dhawaaqa iyo habka soo saarista tamarta dhawaaqa;Midda kale waa marka korantada kor u kaca ay gaarto tamarta tijaabada.marka laga hadlayo.

Marka la eego helitaanka barta resonance ee resonance taxane ah oo kor loogu qaadayo korantada tijaabada, guud ahaan kiiska in korantada adkeysiga ee sheyga imtixaanku aanu u qalmin ama deegaanka goobta aanu ku dhicin isbedel weyn, imtixaanku ma soo saari doono ilaalinta xad-dhaafka ah. ama khaladaad kale.Si kastaba ha ahaatee, maadaama korantada korantadu aysan ahayn mid joogto ah oo tamar-gelinta tamarta korontada ay isbedbedesho, wax-soo-saarka korontadu wuxuu kaloo leeyahay isbeddel gaar ah, kaas oo sababi kara ilaalinta xad-dhaafka ah ee ugu sarreeya ee korantada.Haddii korontadu isbedbedesho, waxaad hagaajin kartaa ilaalinta xad-dhaafka ah ee qalabka, waxaadna dejin kartaa ilaalinta xad-dhaafka ah qiime aad u sarreeya.Waxaan guud ahaan u baahanahay ilaalinta korantada in la dhigo 1.1-1.2 jeer ilaalinta danabka.Waqtigaan, asal ahaan dhib ma laha in la dhigo 1.2 jeer.

Tan sare waa dhibaato fudud, laakiin way ku adag tahay isbedbedelka danabku inuu keeno koronto-dhaafka inuu dhaco marka ilaalinta xad-dhaafka ah la dejiyo.Guud ahaan, xad-dhaafka ah ee is-beddelka is-beddelka soo noqnoqda ee taxanaha tijaabada resonance wuxuu ku jiraa marxaladda xaaqidda soo noqnoqda ee qalabka, taas oo ah, habka lagu helayo barta dhawaaqa.Qof kasta oo isticmaalay aaladda tijaabinta resonance ee taxanaha is-beddelka soo noqnoqda waxa uu og yahay in habka lagu helayo barta dhawaaqa ee aaladda tijaabinta is-beddelka soo noqnoqda, korantada iyo soo noqnoqda waxay leeyihiin xiriir toosan oo la mid ah parabola.Sida caadiga ah, nidaamku wuxuu helaa koronta sare, taas oo ah, vertex ee parabola, sida barta resonance.Maaddaama aragtida mabda'a resonance ay dib u soo celin karto korantada hoose ee korantada ilaa 80 jeer (sababtoo ah qodobka tayada iyo xiriirka kale ee guud ahaan aan ka badneyn 30 jeer), korantada looga baahan yahay xaaqidda soo noqnoqda ee aaladda tijaabinta resonance ee is-beddelka soo noqnoqda guud ahaan waa 20 -50V, iyo danab ka dib excitation guud ahaan waa dhowr boqol oo volts.Iyadoo loo marayo mabaadi'da kor ku xusan, waxaan ogaanay in haddii tamarta tijaabada ah ee alaabta tijaabada ah ee aan u baahanahay ay ka hooseyso tamarta marka nidaamka resonance uu yahay barta resonance, nidaamku wuxuu yeelan karaa ilaalinta xad-dhaafka ah marka uu si toos ah u raadiyo barta resonance.Waqtigan xaadirka ah, dhammaan aaladaha tijaabinta resonance-ka ee taxanayaasha is-beddelka ah uma adkeysan karaan cadaadiska, tijaabada lama dhameyn karo.

Xalka dhibaatadan sidoo kale waa mid dhib badan.Ma aha in aaladaha tijaabinta resonance-ka ee is-beddelka soo noqnoqda aanu dhalin karin tamarta tijaabada, laakiin danab-celinta dhawaaqa ayaa ka sarreeya tamarta tijaabada.Waxaan ognahay in danab resonance default ee nidaamka waa vertex ee parabola ah, taas oo ah in la yidhaahdo, marka parabola kor u kaco In habka vertex ama vertex soo degaya, waxaa jiri doona dhibic la jaan qaada barta danab imtixaanka.Waxaan kaliya u baahanahay inaan tijaabino tijaabada gacanta ee isbedbeddelka isdabajoogga ee taxanaha resonance, oo aan isticmaalno raadinta soo noqnoqoshada buug-gacmeedka si aan u helno barta inta jeer ee la socota korantada la isticmaalo ka dibna u adkeysanno danab si loo xalliyo dhibaatada xad-dhaafka ah ee habka helitaanka barta dhawaaqa.


Waqtiga boostada: Jun-14-2022

Fariintaada noo soo dir:

Halkan ku qor fariintaada oo noo soo dir