Koronto-yaqaannada doonaya in ay sameeyaan tijaabooyinka khasaaraha dielectric-ka ee korontada, relays, capacitors, arresters, iwm. waxay u baahan yihiin inay isticmaalaan tijaabiyaha luminta dielectric-ka ee ka hortagga faragelinta.Sida qalabka tijaabada korantada sare ee caadiga ah, qalabkani wuxuu leeyahay heerar koronto oo sarreeya iyo saxnaan la isku halayn karo.Iyo faa'iidooyin kale, laakiin weli waxaa jira dhibaatooyin badan oo u baahan in fiiro gaar ah loo yeesho habka isticmaalka, markaa waa maxay dhibaatooyinka ay tahay in fiiro gaar ah loo yeesho marka la isticmaalayo tijaabiyaha luminta dielectric anti-faragelinta?Maqaalkan, HV HIPOT waxay ku siin doontaa hordhac kooban.
HV HIPOTAwooda GD6800 & Tijaabada Tan Delta
1. Dhulka u dhig si la isku halleyn karo si aad u hubiso in qolofka qalabku uu yahay mid awood dhulka ah.
2. Siidaynta togan: Geli furka fiilada korantada-sare ee godka HV ee qalabka, ku dheji fiilada aligator-ka madow ee hal daraf ah hogaanka alaabta la tijaabiyay, oo ku laad fiilada aligator-ka cas hawada.Geli fiilada korantada yar ee Cx gudaha godka Cx, fiilada cas ee dhinaca kale waxay ku dhejinaysaa dhammaadka hoose ama shaashadda dhamaadka muunadda tijaabada, iyo clip-ka madow waa la hakiyay ama ku xiran yahay qalabka gaashaanka.
3. Marka fiilooyinka gadaale: Geli fiilada korantada-sare ee godka HV ee aaladda, ku dheji fiilada aligator-ka gaduudan hal daraf oo hogaanka alaabta la tijaabiyay, oo sudh fiilada madow hawada ama ku xidh gaashaanka. qalab.Socket-ka Cx lama isticmaalo.
4. U hoggaansamo shuruudaha "Sharciga Shaqada Badbaadada ee Imtixaannada Korantada Sare".
5. Imtixaanka cadaadisku waa in ay ka soo qaybgalaan in ka badan 2 xubnood oo shaqaale ah, midna shaqaynayo midna kormeerayo.
6. Kadib marka fiilooyinka la dhammeeyo, hal qof ayaa ka mas'uul ah kormeerka.
7. Kadib marka uu imtixaanku dhamaado, dami dabkaSi adag ayaa loo mamnuucay in la kala diro ama la isku keeno fiilada korontadu ku badan tahay!
8. Haddii qalabku uu yahay mid aan caadi ahayn, dami dabka oo sug ilaa hal daqiiqo si aad mar kale u hubiso.
9. Ka dib marka cabbirka la dhammeeyo, dab-damiska waa in la damiyaa, sug ilaa hal daqiiqo, ka dibna ka saar fiilada.
Waxaa jira taxaddarro badan oo loogu talagalay isticmaalka tijaabiyaha Capacitance & Tan Delta.Habka isticmaalka, shaqaalaha korontadu waxay u baahan yihiin inay fiiro gaar ah u yeeshaan si ay si adag u raacaan tilmaamaha buug-gacmeedka, si ay u helaan laba jeer natiijada dadaalka kala badh.
Waqtiga boostada: Nov-02-2021