Badhtamihii bishii March, macmiil ku sugan Beijing ayaa telefoon kula xidhiidhay shirkadeena si uu wax uga weydiiyo qiimaha set of "transformer bushing localized on-line monitoring system".Ka dib markii ay wada hadleen maamulaha iibka ee gobolka iyo injineerka farsamada iyo macaamiisha, dhammaan badeecadaha loo baahan yahay iyo cabbirada ku habboon ayaa lagu go'aamiyay 2 maalmood oo keliya, labada dhinac ayaa ugu dambeyntii saxiixay qandaraas iskaashi.
HV Hipot GDPD-BR-OL Transformer Bushing PD Nidaamka Kormeerka onlaynka ah
Transformer-ka PD ee nidaamka la socodka khadka tooska ah wuxuu ku habboon yahay kormeerka khadka-line iyo ka-baxsan ee qayb ka mid ah qulqulka qulqulka beddelka ee leh heerarka korantada ee 110kV iyo wixii ka sarreeya.Nidaamka kormeerka qayb ka mid ah wareejinta khadka tooska ah ee lagu sameeyay iyadoo la isku darayo tikniyoolajiyadda farsamaynta calaamadaha dhijitaalka ah iyo tikniyoolajiyadda aaladaha farsamada ayaa loo adeegsadaa kormeerka baadiyaha beddelka ee 110KV iyo wixii ka sareeya, waxayna kaydin kartaa tijaabada tijaabada ee weji kasta si loo ogaado cilladaha dahaarka ee kaynta transformer-ka, oo la bixiyo shuruudaha lagu qiimeeyo heerka dahaarka iyo heerka gabowga, iyo in la bixiyo aasaaska shaqada dayactirka transformerka.
Cabbirka dheecaanka ugu yar ee nidaamkan: 20mV (goobta), inta jeer ee soo noqnoqda waa 200kHz ~ 300MHz, xallinta wakhtiga garaaca garaaca waa 10μs, xallinta wajiguna waa 0.18 °.
Nidaamku wuxuu bixiyaa jaantuska dareeraha wareegga wareegga awoodda 50, laba-cabbir (q-φ, N-φ, Nq), saddex-cabbir (Nq-φ) spectrum, kaas oo loo isticmaali karo in lagu falanqeeyo nooca dheecaanka.
Xogta ay dhistay MySQL waxa ay diiwaangelin kartaa isku xigxiga wejiga cabbirka, qaddarka soo daynta, marxaladda sii daynta, wakhtiga cabbirka iyo cabbirrada kale ee la xidhiidha
Sidoo kale cabbirrada qalabka sida moodalka buushka beddelka, goobta cabbirka, iwm., waxay bixin kartaa garaafyada isbeddelka sii daaya waxayna yeelan kartaa digniin hore iyo hawlo qeylo dhaan ah, waxayna waydiin kartaa, tirtiri kartaa, oo kaydin kartaa xogta xogta.
Nidaamku waxa uu qaataa tillaabooyin ka hortag ah oo dhammaystiran sida shaandhaynta dhijitaalka ah iyo dejinta marinnada firfircoon, xogta imtixaankuna waa run oo la isku halayn karo.
Ku qanacsanaanta macaamiishu waa xooggayaga wadista!Mustaqbalka, HV Hipot ma iloobi doonto ujeedadeedii asalka ahayd, horay u sii waday, oo waxay la shaqayn doontaa macaamiisha cusub iyo kuwii hore si ay u siiyaan qalab iyo adeegyo ka wanaagsan nidaamka tamarta iyo ka caawinta nidaamka korontadu inuu si fiican u shaqeeyo.
Waqtiga boostada: Mar-24-2022