Tijaabiyeha GDYZ-302W Birta Oxide Qabaha (MOA).
1) Dhaqdhaqaaqa hadda jira, AC hadda
Range | Qaraarka | Saxnaanta |
0.000mA~1mA | 1uA | ±1%rdg±8dgt |
1.00mA~10.00mA | 0.01mA | |
10.0mA~100.0mA | 0.1mA | |
100mA~300mA | 1mA |
2) Dhaqdhaqaaqa iswaafajinta ee nidaamka sare leh (mawjada aasaasiga ah ee hadda jirta, hadda hadmniga saddexaad)
Mawjada aasaasiga ah ee ugu yar hadda | In ka badan 3% nooc kasta |
Saxnaanta | 1%rdg±8dgt (± AC saxnaanta hadda) |
Shaqada | Marka la tijaabiyo wakhtiga buuxa ee xidheha zinc oxide, waxa lagu qiimayn karaa onlayn in xadhig-xidhaha zinc oxide uu xumaaday iyo in kale, waxa kale oo loo isticmaali karaa mitirka xaadirka ah ee aadka u saxsan. |
Korontada | Hawl-wadeen: DC 7.4V 2000mAh baytari lithium ah oo dib loo dallaci karo, batarigu wuxuu ku saabsan yahay 8.4V si buuxda u dallacayBatari: DC 7.4V 2600mAh baytari lithium ah oo dib loo dallaci karo, batarigu waxa uu ku saabsan yahay 8.4V si buuxda u dallacay |
Habka tijaabada | Isku-qabsiga CT |
Qiyaasta kala duwan | AC 0.000mA~300mA (qiimaha waxtarka leh ee runta ah) |
Max.xallinta | 1μA |
Saxnaanta cabbirka | ±1%rdg±8dgt (23℃±5℃, ka hooseeya 80% RH) |
Isgaarsiinta wireless | 433 MHz isgaarsiinta wireless |
Fogaanta gudbinta wireless-ka | 30m |
Qaabka muuqaalka | 3.5-inch midabka shaashadda;goobta bandhiga: 71mm×53mm |
Cabbirka qalabka | Martigeliyaha: 195mm×100mm×45mm;Baaraha: 208mm×131mm×90mm |
Miisaanka qalabka | Martigeliyaha: qiyaastii 400g;qalabka: qiyaastii 1220g,Wadarta: qiyaastii 7000 g (oo ay ku jiraan ulaha dahaarka iyo qalabyada) |
Cabbirka xajin | φ40mm |
Heerka saamiga | 2 jeer/s |
Kaydinta taariikhda | 200 oo kooxood, calaamad "HOLD" waxay tilmaamaysaa inta lagu jiro kaydinta. |
Xog haynta | Habka tijaabada, riix furaha HOLD si aad u ilaaliso xogta oo aad u kaydiso, calaamadda "HOLD" ayaa soo muuqanaysa, ka dibna taabo furaha HOLD si aad u tirtirto. |
Hubinta xogta | Astaanta "AKHRISO" waxay tusinaysaa in xogta la kaydiyay kor iyo hoos loo rogi karo. |
Qulqulka | "OL” waxay muujinaysaa qulqulka xad dhaafka ah ee tijaabada. |
Calaamad malaha | Marka aqbalaha martigeliyaha uusan helin calaamadda wax-beegaha, xaaladda hadda jirta ee baaruhu lama soo bandhigi karo. |
Si otomaatig ah | Qalabku si toos ah ayuu u dami doonaa 10 daqiiqo ka dib si uu u badbaadiyo batteriga. |
danab batari | Marka danabku uu ka hooseeyo 7.8V, waxay muujinaysaa in la joogo waqtigii la bedeli lahaa batteriga. |
Voltage line | 35kV iyo ka hooseeya |
Heerkulka deegaanka iyo qoyaanka | -20℃~40℃; hoose80% Rh |
Kaydinta | -20℃~60℃;hoose70% Rh |
Faragelin | No 433Mhz faragelinta soo noqnoqda |
Cabbirka usha dahaarka | 4-qayb riix-badhan usha dahaadhka telescopic (gobolka fidsan 5m, gobolka xidhan 1.5m, dhexroorka dibadda φ44mm) |
Xoogga dahaarka | Usha kaliya ee dahaarka AC110kV/rms, qolofka HVbaarahainta u dhaxaysa xudunta birta: AC1000V/rms |