GDW-102 Tijaabada Dhibabka Saliida (Coulometric Karl Fischer Titrator)
Tiknoolajiyada Coulometric Karl Fischer waxaa lagu dabaqaa si loo cabbiro si sax ah loo raadiyo qoyaan muunada la cabiray. Tignoolajiyada ayaa si weyn loogu isticmaalaa saxnaanta iyo qiimaha tijaabada jaban.Model GDW-102 wuxuu si sax ah u raadiyaa qoyaanka dareeraha, shayyada adag iyo gaaska sida ku cad tignoolajiyada.Waxa loo isticmaalaa koronto, batroolka, kiimikooyinka, cuntooyinka iyo wixii la mid ah.
●Isticmaal wareegga korantada ee PWM ee la hagaajiyay si loo yareeyo daminta awoodda qalabka.
●Calaamadaha korantada ee cabbiraadda saxda ah ee saxda ah iyo ogaanshaha wareegga ayaa si degdeg ah oo sax ah u sameeya go'aanka dhammaadka elektrolytka oo leh awood xooggan oo ka-hortagga faragelinta.
●Isticmaal hababka elektrolytka ee bannaan ee magdhowga hadda iyo dheelitirka korantada si aad u dejiso natiijada baaritaanka.
●Lagu dhisay saddex qaacido xisaabeed si loo soo saaro warbixinta si toos ah.
●Badhamada xakameynaya xawaaraha isku dhafka waxay leeyihiin toban xawli (0 ~ 9xawaaraha).
●Si otomaatig ah u cabbir qaladka wareegga wareegga-gaaban iyo cilladda korantada.
●Waxay kaydin kartaa 256 diiwaanka taariikhda waqti.
●Saacadda kalandarka ee leh heerkulku waxay si toos ah u kaydin kartaa taariikhda iyo wakhtiga tijaabada si sax ah, taas oo shaqayn karta 10 sano ka koraysa iyadoo korontadu hoos u dhacday.
●Marka qalabku uu shaqayn waayo muddo dheer, shaashadda LCD si toos ah ayay u xirmi doontaa si ay u ilaaliso shaashadda oo ay u sii jirto nolosha shaashadda.Riix badhamada kasta si aad uga baxdo ilaalinta shaashadda.
●Waxaa jira interface RS232 si ay ugu xidhmaan PC iyo mini-printer si fudud.
Electrolysis hadda | Max.400mA |
Korodhka ugu sarreeyaxawaaraha | Max.2.4mg/min |
Qiyaasta kala duwan | 10ug~100mg |
Dareenka | 0.1ug |
Saxnaanta | ±3ug ilaa 10ug~1mg RSD 0.3% ama ka yar 1mg ama ka badan |
Heerkulka deegaanka | 5~35℃ |
Qoyaanka deegaanka | ≤85% RH |
Bixinta Korontada | AC220V± 20% 50HZ±10%,40VA |
Cabirka | 270×210×125(mm) |
Miisaanka | 5kg |
Isticmaalka tamarta ugu badan | 30W |
Unugga ugu muhiimsan | 1 gabal |
Electrolysis electrode | 1 gabal |
Cabbirka korantada | 1 gabal |
lowska walaaqaya | 2 pcs |
Qayb jel silica | 1 gabal |
Marin jel silica | 10 pcs |
0.5 μl Muunad mudista | 1 gabal |
50 μl Tusaalaha mudista | 1 gabal |
1ml muunad mudista | 1 gabal |
Tuubada qalajinta | 1 gabal |
Xadhiga korantada | 1 gabal |
Dufan faaruq ah | 1 gabal |
Electrolytka | 1 gabal |
Tilmaamaha isticmaalaha | 1 koobi |
Warbixinta tijaabada warshadda | 1 koobi |