GDSL-D Taxanaha Dijital ah ee aasaasiga ah ee Tijaabada Hadda
●DL/T 596-2005 "Nidaamka Tijaabada Habka Qalabka Korantada"
●GB1094.1-GB1094.6-96 "heerka ilaalinta Shell"
●GB2900 "Erayga Korontada"
●GB/T16927.1 ~ 2-1997 "Technology Test Voltage High"
●GB4793-1984 "Shuruudaha Badbaadada ee Qalabka Qiyaasta Elektrooniga ah"
●GB191 "Baakadda Kaydinta iyo Calaamadda Gaadiidka"
●GB/T.311-1997 "Insulation and coordination of high voltage power transgress and transformation equipment"
●Isticmaalka naxaasta conductivity sare sida electrode soo saarka, oogada xidhiidhka waa weyn iyo awoodda socodka waa xoog badan.
●Saxan aluminium ah oo la caday oo leh hannaan cusub, fudud oo soo jiidasho leh, xidhashada u adkaysta iyo wasakhowga u adkaysata.
●Kiiska caaga ah ee buufinta birta ah oo dhan iyo codka cawlan ee caalamiga ah ee geela waa mid adag oo la isku halayn karo, hubinta isku halaynta saadka.
●Isticmaalka xajiyeyaasha caalamiga ah ee biriiga ayaa dhaqdhaqaaqa iyo hagaajinta ka dhigaya kuwo dabacsan oo habboon.
●Dhuumaha qulqulka hawada u qaabaysan si loo hagaajiyo diridda kulaylka oo si weyn u kordhiso nolosha adeegga.
●Mashiinka oo dhan waa mid yar oo miisaankiisu yar yahay, miisaankiisuna wuu yar yahay, kaas oo aad ugu habboon isticmaalka goobta.
●Waxay leedahay shaqo ilaalin eber ah si ay uga hortagto saameynta hadda weyn inay waxyeello u geysato saamiga.Lama bilaabi karo marka aysan eber ku jirin.
●Shaqada xulashada saamaynta, marka wareegga degdegga ah ee jebinta degdega ah la sameeyo, shaqada ilaalinta eber waa la gooyn karaa oo qiimaha hadda loo baahan yahay si toos ah ayaa loo soo saari karaa.
●Qaabka hadda la soo saaray: Qiimaha RMS ee runta ah si joogto ah ayaa loo hagaajin karaa.
●Wax-soo-saarka hadda jira waa mawjadda sinaha ee caadiga ah, iyo heerka qallooca waveform wuxuu ka yar yahay 5%.
●Voltage iyo bandhiga hadda ayaa qaadanayabandhig dhijitaalka ah oo cusub oo sax ah oo LED ah
●Qiyaasta la bedeli karo ee kala duwan ee hadda si loo wanaajiyo wanaagga muujinta akhrinta saxda ah.
●Korontada sahayda korantada iyo korantada wax soo saarka hagaha ayaa loo rogi karaa si ay u muujiso si sahlan loo daawado.
●Awoodda qalabka waxaa loogu talagalay wakhti gaaban, shaqo ku meel gaar ah 5 daqiiqo.
●Tijaabada dufcada, xidh 10 daqiiqo ka dib 2.5 daqiiqo oo qalliin joogto ah.
●Waxay cabbiri kartaa wakhtiga ficilka hadda ee qaybta la tijaabiyay oo waxay u duubi kartaa wakhtiga waxqabadka qufulka si isku mid ah.(ikhtiyaar)
●Qiyaasta wakhtiga la qiyaasay: 0.001S~999.999S Qaraarka 1ms, khalad cabbirka: 0.005% kala duwan ± 2digs.(ikhtiyaar)
●Qiimaha tijaabada ee hadda hoose iyo kan sare ayaa si toos ah loo soo bandhigi karaa si loo fududeeyo saamiga beddelka.(ikhtiyaar)
●Kala duwanaanta hadda jirta ee labaad 0 ~ 5A xallinta 1mA (ikhtiyaar)
●Haddii heerkulku kor u kaco (30 daqiiqo - 24 saacadood) waa in lagu beddelaa iyadoo loo eegayo kor u kaca heerkulka shaqada ee muddada-dheer.(ikhtiyaar)
●Waxa lagu habayn karaa saddex waji oo leh kor u kaca hagaajinta dheelitirka (ikhtiyaar)
●Waa la habeyn karaa AC iyo kororka DC (ikhtiyaar)
Qaabka | Awoodda wax-soo-saarka(kVA) | Wax soo saarka hadda(A) | Bixinta Korontada(V) | Furan danabka wareegga(V) | Pwejiga ower | Calaamadee | |
GDSL-D-500 | 3 | 500 | 220 | 6 | LN | Integrated | |
GDSL-D-1000 | 6 | 1000 | 220 | 6 | LN | Integrated | |
GDSL-D-1500 | 9 | 1500 | 220 | 6 | LN | Integrated | |
GDSL-D-2000 | 12 | 2000 | 220 ama 380 | 6 | LN | AB | Integrated ama isku dhafan |
GDSL-D-2500 | 15 | 2500 | 220 ama 380 | 6 | LN | AB | Integrated ama isku dhafan |
GDSL-D-3000 | 18 | 3000 | 220 ama 380 | 6 | AB | Integrated ama isku dhafan | |
GDSL-D-4000 | 24 | 4000 | 380 | 6 | AB | isku darka | |
GDSL-D-5000 | 30 | 5000 | 380 | 6 | AB | isku darka | |
GDSL-D-6000 | 36 | 6000 | 380 | 6 | AB | isku darka | |
GDSL-D-8000 | 48 | 8000 | 380 | 6 | AB | isku darka | |
GDSL-D-10000 | 60 | 10000 | 380 | 6 | AB | isku darka | |
GDSL-D-12000 | 72 | 12000 | 380 | 6 | AB | isku darka | |
GDSL-D-15000 | 90 | 15000 | 380 | 6 | AB | isku darka | |
Waa la beddeli karaa iyadoo ay ugu wacan tahay shuruudaha gaarka ah ee macmiilka |
Tijaabada duridda aasaasiga ah ee hadda jirta | 1 gabal |
Xadhiga korantada | 1 gabal |
Siligga dhulka | 1 gabal |
Khadka Hadda Sare (Heerka 2m) | 2 gabal |
Shahaado | 1 koobi |
Buugga | 1 koobi |
Liiska baakad | 1 koobi |
Warbixinta Imtixaanka | 1 koobi |