GDJW-40B Tijaabaha Insulator Wireless Wireless
GDJW-40B waxaa loo isticmaali karaa si loo tijaabiyo voltag qaybinta ee dallaal hakiyay eeday ama ogaanshaha shaybaarka ee insulator la hakiyay, iyo awood in si wax ku ool ah loo ogaado dhibaatada qarsoon gudaha insulator ah, hagaajinta isku halaynta hawlgalka ee nidaamka grid korontada, iyo wanaajiyo. hufnaanta shaqo ee shaqaalaha khadka ee fulinaya imtixaanka tooska ah.Alaabtani waxay qabataa gudbinta wireless-ka, masaafada isgaadhsiinta ee u dhaxaysa qalabka wax baadha iyo terminaalka gacanta lagu hayo wuxuu gaari karaa ilaa 100m kor ku xusanIntaa waxaa dheer, qalabku wuxuu leeyahay waxqabad aad u xoog badan oo ka-hortagga faragelinta, si buuxda u hoggaansamaya shuruudaha caadiga ah (EMC), la qabsiga xaaladaha kala duwan ee faragelinta korantada.
●Danab shaqeynaya: 35-1000KV, heerarka danab kala duwan ayaa lagu dabaqi karaa.
●Cabbirka cabbiraadda korantada: 0-40kV (danab gaar ah ayaa la beddeli karaa).
●Khaladka cabbirka: ≤±1%.
●Heerka saamiga: 10 jeer/S.
●Dejinta wakhtiga taariikhda: hagaajin taariikhda iyo wakhtiga, si loo fududeeyo isticmaalayaasha si ay wax u baadho, u arkaan xogta taariikhiga ah.
●Dejinta wakhtiga iftiinka dambe: iftiin joogto ah, dansan, 0-999 daqiiqo ayaa la dejin karaa.
●Deminta dejinta otomaatiga ah: marnaba, 0-999 daqiiqo ayaa la dejin karaa.
●Fogaanta gudbinta ee terminaalka gacanta lagu qabto iyo qalabka wax sheeguhu waa ≤100m.
●Naqshadaynta qaab-badan, ku-dhaqanka xooggan, ammaan badan oo habboon.
●Naqshadaynta wadajirka ah ee caalamiga ah, waxay awood u siineysaa inay si dabacsanaan ah u hagaajiso jihada cabbirka iyadoo loo eegayo booska ka joojinta ee xadhigga daaha.
●Laba-jibbaaran, awood xoog leh oo ka-hortagga faragelinta, si buuxda ugu hoggaansan heerarka EMC.
●Interface man-chine gaar ah, fududahay in lagu shaqeeyo.
Qiyaasta korantada | 0-40kV (danab gaar ah ayaa la beddeli karaa) |
Khaladka cabbiraadda | ± 1% |
Qaraarka | 0.01kV |
Heerka saamiga | 10waqtiyo/S |
Hadda shaqaynaysa | ≤120mA(Terminalka gacanta lagu hayo),≤40mA(Baaraha) |
Korontada | 2*1.5VAA baytari qallalan (Terminalka gacanta lagu hayo) 2*1.5VAAA baytari qalalan (Baaraha) |
Waqti shaqo oo joogto ah | ≥12h |
Fogaanta gudbinta | ≥100m (koronto ku filan) |
Bandhig | Muujinta LCD, si cad ayaa loogu soo bandhigi karaa qorraxda hoosteeda. |
Heerkulka shaqada | -35℃---+60℃ |
Heerkulka kaydinta | -40℃---+65℃ |
Qoyaanka qaraabada | ≤90%RH Non-condensate |
Maya | Qaabeynta aasaasiga ah | Unug | Qty. | Odhaah |
1 | Terminalka gacanta lagu hayo | dhigay | 1 | |
2 | Baaraha u go'ay | gabal | 1 | |
3 | A,B Baaraha | xidid | 2 | |
4 | AA batari qallalan (1.5V) | qaybta | 2 | |
7 | AAA baytari qallalan (1.5V) | qaybta | 2 | |
8 | Kiiska la soo dejiyo | gabal | 1 | |
9 | 220kV Usha dahaarka | xidid | 1 | ≤220kV ku habboon4qaybaha4M usha dahaarka,≥330kV ku habboon6 qaybaha6M usha dahaarka |
10 | Buugga hawlgalka | nuqul | 1 | |
11 | Warbixinta tijaabada | nuqul | 1 | |
12 | Kaarka dammaanadda | nuqul | 1 | |
13 | Liiska baakad | nuqul | 1 |