GDJB-6000D Nidaamka Tijaabada Ilaalinta Wareejinta Substation Smart
GDJB-6000D waxay ku qalabaysan tahay cod-weyneeye awoodeed oo heersare ah oo ku salaysan madal PowerPC+X86 oo awood badan.Waxay qabataa nashqad qaabaysan waxayna leedahay hawlo awood leh, saxsanaan sare, cabbir yar iyo astaamo fudud.Waxay tijaabin kartaa shaqada iyo waxqabadka unugga isku-darka, aaladda ilaalinta gudbinta, cabbirka iyo aaladda xakamaynta, marinnada caqliga iwm
●Module Imtixaanka Wacan
Tafatirka qaabka tijaabada caqliga waa la taageerayShayada tijaabada ayaa si aan kala sooc lahayn loogu dari karaa inta lagu jiro nidaamka tijaabada waxaana loo kaydin karaa sidii faylalka mashruuca tijaabada dib loo isticmaali karo si loo horumariyo waxtarka tijaabada ee heerka ugu dambeeya ee kormeerka iyo baabi'inta.
●Tijaab toos ah
Iyada oo la ilaalinayo goobta iyo ilaalinta dhijitaalka ah ee shaqada tijaabada tooska ah, dhammaan shayyada tijaabada ee hal qalab ilaalin ayaa lagu dhamaystiri karaa hal fure.
●Hababka iskaanka ee badan
Waxay taageertaa baaxadda, wejiga, soo noqnoqda, impedance, vector, taxanaha, iyo awoodda waxaa lagu fuliyaa imtixaan gacanta ama si toos ah, sidoo kale waxay taageertaa tijaabada isbeddelka tooska ah iyadoo loo eegayo habka qalin-jabinta, silbashada iyo isku-dhafka.
●Bandhig garaaf ahaan terminal Virtual
Taageer shaqada bandhiga garaafiga ah ee terminal, socodka xogtu waa caddahay.
●Dir oo hel fariimaha isku mar
Taageer IEC61850-9-1, IEC61850-9-2 iyo GOOSE soo saarida fariinta dhijitaalka ah.Calaamadaha GOOSE waa la diri karaa oo waa la heli karaa si madaxbannaan, sidoo kale waxay soo diri kartaa oo ku heli kartaa interface Ethernet-ka IEC 61850-9-2.
●FT3/Faddinta FT3
Taageer FT3, FT3 ballaarinta iyo DL/T 282 soo saarida fariinta, iyo taageer 2M/4M/6M/8M/10M baud heerka UART codeing iyo 5M/10M/20M Manchester encoding.
●Baaritaan aan caadi ahayn
Farriimaha analooga ah ee shaqaynta aan caadiga ahayn, waxay la jaanqaadi kartaa cilladda aan caadiga ahayn ee tayada, dirista soo noqnoqoshada jitter, dib u dhigista cilladda, luminta xirmada, tallaabo ka baxsan, nambarka taxanaha boodada, qaabka dayactirka, isbeddelka farsamada ee gobolka iyo imtixaanno kale.
●Dib u ciyaarida qalad
Waxay taageertaa jilidda khaladka ah iyo qaabka COMTRADE xogta dib u soo celinta
●adeegga MMS
Shaqada akhriska iyo qoraalka MMS, waxay akhrin kartaa oo qori kartaa jaangooyada qalabka IED ee caqliga leh iyo macluumaadka qaabeynta kale.
●Isku-dubarid waqti iyo waqti-siinta
Iyada oo leh shaqeynta kicinta isku-dhafka ah, taageerada gelitaanka tooska ah ee anteenada GPS/BD ee isku-xirnaanta waqtiga, waxay sidoo kale taageertaa IRIG-B, PPS iyo PTP 1588 qaab waqti waxayna taageeri kartaa wax-soo-saarka dibadda IRIG-B, PPS iyo PTP 1588 waqtiga bixinta.
●Soo gelinta binary xiriir adag iyo wax soo saarka binary
Tirada wax gelinta ayaa ah kuwa firfircoon oo la qabsiga la qabsiga ah, iyo nooca gelinta iyo danab-gelinta si toos ah ayaa loo aqoonsanayaa.Kanaalada waa ka go'doonsan yihiin midba midka kale, oo polarity-ku wuxuu beddelaa xiriirka degdegga ah.
●Farriinta iyo falanqaynta
Marka la helo fariinta iyo falanqaynta shaqada, fariinta la helay waxaa lagu furi karaa ZHNPA si loo falanqeeyo ama loo dhoofiyo.
●Qaabka kaliya ee fiber-ka
Dekeddu waxay taageertaa gudbinta hal-fiber iyo soo dhawaynta hal-fiber waxayna taageertaa tijaabinta awoodda indhaha.
●Analog yar signal
Waxay ku qalabaysan tahay interface-ka yar ee analoogga ah, taageerada 12-dariiqa analogga ah ee gelinta calaamadaha yar-yar, waxay cabbiri kartaa -7V ~ 7V AC danab, taageer 12 hab analog wax soo saarka signal yar, oo soo saari kara -7V ~ 7V AC danab.
●Hawlgalka taabo
Ku qalabaysan muraayad 10.4 inch ah oo cabbir sare leh oo taageerta hawsha taabashada.
●Isku xirka wireless
Bixi shaqada tijaabada fog, oo leh moduleka WiFi, isticmaale-saaxiibtinimo.
IEC 61850 dekedda isgaarsiinta | |
Shaqada | Habayn kasta oo IEC 61850 9-1/9-2 SMV gudbinta, helitaanka ama GOOSE gudbinta iyo soo dhawaynta |
Nooca Interface | LC dekedda indhaha |
Tirada | 8 lammaane, 6 lammaane * 100M laqabsiga, 2 lammaane * 100/1000M laqabsiga |
Dhererka hirarka | 1310nm |
IEC 60044 dekedda isgaarsiinta | |
Shaqada | GB/T 20840.8, DL/T 282, Q/GDW441 fariinta helida iyo dirida |
Nooca Interface | ST |
Tirada | 6 * diraya interface, 2* helitaanka interface |
Marxaladda | |
Range | 0 ~ 360° |
Saxnaanta | ±0.1° |
Qaraarka | 0.1° |
Soo noqnoqda | |
Range | 0 ~ 1000Hz |
Saxnaanta | <±0.001Hz (0 ~ 65Hz) <±0.01Hz (65 ~ 450Hz) <±0.02Hz (450 ~ 1000Hz) |
Qaraarka | 0.001Hz |
Waqtiga | |
Range | 10ms ~ 9999.999s |
Qaraarka | 1ms |
Gelida xiriirka binary | |
Tirada | 8 lammaane, waa lagu xidhi karaaxiriir la'aan iyo xiriir suurtagal ah (0 ~ 250V) |
Soo saarida xiriirka binary | |
Tirada | 6 lammaane, 2 lammaane ayaa si degdeg ah wax u soo saara |
Awood jabinta | DC250V /0.5A |
Waqtiga jawaabta | <100us |
Isku xidh | |
Nooca Interface | GPS/BD ANT;IRIG-B/PPS calaamadda indhaha;IRIG-B/PPS calaamad koronto;IEEE 1588 |
Tirada | 1*GPS/BD NT; 2 * IRIG-B / PPS ishaarka indhaha: 1 * waqti isku-dubarid, 1 * waqti bixinta; 2 lammaane * IRIG-B/PPS calaamad koronto: 1 lammaane * waqti isku-dubarid, 1 lammaane * waqti bixinta; 1 lammaane* IEEE 1588 |
Isku xirka wireless | |
Nooca Interface | WIFI |
Isku xirka fiilada | |
Nooca Interface | 100M Lan dekedda, RJ45 |
Tirada | 2 xabbo |
Gelida signal yar Analog | |
Nooca Interface | Furaha duulista, danab AC |
Tirada | 12 kanaal |
Analog yar soo saarista signal | |
Nooca Interface | Furaha duulista, danab AC |
Tirada | 12 kanaal |
Korontada | |
Voltage | AC/DC 220V, weecasho la ogol yahay: -20%~15% |
Soo noqnoqda | 47 ~ 65Hz |
USB interface | |
Tirada | 2 xabbo |
Deegaanka shaqada | |
Heerkulka shaqada | -10℃~50℃ |
Qoyaanka | ≤95%,aan uumi lahayn |
Kuwo kale | |
Miisaanka | 5.5 kg |
Cabirka | 146×390×212mm (L×W×H) |
Interface | RJ45 |
Bandhig | 10.4 inch midabka dhabta ah LCD taabashada |